Background: Temporomandibular joint disorder (TMD) is a general term that describe a wide variety of conditions that include myogenic pain, internalderangement, arthritic problem, ankylosis of the joint and growth disorders. The aims of study was to evaluate the value of 3 Tesla magnetic resonance imaging in assessment of articular disc position and configuration in patients with temporomandibular joint disorders and to evaluate the correlations of these MRI findings with the clinical signs and symptoms. Materials and methods: A total forty six (30 study and 16 control) participants aged between18 and 49 years, were examined according to Helkimo anamnestic index (questionnaire for anamnesis) and clinical dysfunction index scoring criteria which include clinical examinations of the range of mandibular mobility, impaired TMJ function, muscle pain ,TMJ pain and pain during mandibular movement. Results: There is statistically high significant difference between Helkimo anamnestic and clinical dysfunction indices in the cases group (with temporomandibular joint disorders) and controls group with MRI findings of disc position and disc configuration, that as the severity of indices increased, there were progression of disc displacement and disc deformity score and shows positive association expressed by significant probability (p) value. Conclusion: There is a significant correlation between Helkimos’ anamnestic and clinical dysfunction indices and MRI findings in patients with internal derangement of temporomandibular joint.
Autorías: Ismael Saleem Abed, Imad Kadhim Khlaif, Salah Mahmood Salman. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 5, 2022. Artículo de Revista en Dialnet.
Background: Tear of MCL of the knee is a frequent problem among knee ligaments injuries.Injuries to the MCL are usually caused by contact on the outside of the knee and are accompanied by sharp pain on the inside of the knee. Contrary to most other knee ligaments the medial collateral ligament (MCL) has an excellent ability to heal, being fairly large and well vascularised structure. The vast majority of isolated medial ligament injuries heal without significant long-term problems
Objectives: is to compare between the early clinical examination, and assessment under general anesthesia (GA), and to find out the best methods to assess the MCL tear especially in suspected cases.
Type
... Show MoreAbstract:The optimum design of the magnetic deflector with the lowest values of the radial and spiral distortion aberration coefficients was computed. The optimized calculations were made using three models, Glaser bell-shaped, Grivet-lenz and exponential models. By using the optimum axial field distribution, the pole pieces shape which gave rise to those field distributions was found by using the reconstruction method. The calculations show that the results of the three models coincide at the lower values of the excitation parameter. In general the Glaser- bell shaped model gives the optimum results at the whole range of the excitation parameter under investigation.The negative values of the spiral distortion aberration coefficient appears
... Show More
Abstract
The current research aims to identify the impact of triangular bridging strategy in the acquisition of sociology of fourth-stage students. To achieve the research objective, the following null hypotheses were adopted: there are no statistically significant differences at a significance level (0, 05) between the average grades of the experimental group students who studied the triangular bridging strategy in acquiring concepts of sociology and average grades of the control group. The researcher has selected the fourth-stage students from Alexandronah School for girls that s related to the Directorate General of Baghdad the sample consisted of (87) students at litera
... Show MoreObjective: To evaluate the functional outcomes after extended curettage and reconstruction using a combination of bone graft and bone cement (sandwich). Methodology: In this prospective case series 16 skeletally mature patients with primary giant cell tumor around the knee were included. Patients with previous surgically treated, malignant transformation, degenerative knee changes and those presenting with pathological fracture were excluded. The tumor was excised with bone graft filling space beneath the articular cartilage and a block of gel foam was placed over the cortical surface of picked bone graft. Remaining cavity was filled with polymethylmethacrylate cement (sandwich) with or without internal fixation. The func tional evaluation
... Show MoreMagnetic resonance cholangiopancreatography (MRCP) is a non-invasive imaging test with excellent overall sensitivity and specificity for demonstrating the level and the presence of a biliary obstruction. MRCP has emerged as an accurate, diagnostic modality for investigating the biliary and pancreatic duct. In some cases, it has been recommended that preoperative MRCP is a good choice for the detection of CBD stones.
The aim of the s
The design of components subjected to contact stress as local compressive stress is important in engineering application especially in ball and socket Joining. Two kinds of contact stress are introduced in the ball and socket joint, the first is from normal contact while the other is from sliding contact. Although joining two long links (drive shaft in steering cars) will cause the effect of flexural and tensional buckling stress in hollow columns through the ball and socket ends on the failure condition of the joining mechanism. In this paper the consideration of the combined effect of buckling Load and contact stress on the ball and socket joints have been taken, epically on the stress distribution in the contact area. Different
... Show MoreIn this paper, a theoretical study of the energy spectra and the heat capacity of one electron quantum dot with Gaussian Confinement in an external magnetic field are presented. Using the exact diagonalization technique, the Hamiltonian of the Gaussian Quantum Dot (GQD) including the electron spin is solved. All the elements in the energy matrix are found in closed form. The eigenenergies of the electron were displayed as a function of magnetic field, Gaussian confinement potential depth and quantum dot size. Explanations to the behavior of the quantum dot heat capacity curve, as a function of external applied magnetic field and temperature, are presented.