Preferred Language
Articles
/
jbcd-1858
A Comparison of Vertical Marginal Fit of different Brands of Translucent Zirconia Crown Restorations
...Show More Authors

Background: As the development of zirconia crown using CAD/CAM technology, the usage of full zirconia crown is gradually increased. The aim of this in-vitro study was to evaluate and contrast the vertical marginal fit of single all-ceramic translucent zirconia crowns constructed from different brands translucent zirconia blanks. Materials and Methods: An acrylic resin model of a left maxillary premolar was prepared all around the tooth with (1 mm) depth and 3D scanning to get fifteen STL files, then distributed into three groups (Imes-icor, Whitepeaks and Dental direct), 3D scanning and milling machine by Imes-icor CAD/CAM devise. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) using a light microscope at a magnification of x100. One-way ANOVA, LSD tests were performed to determine the mean and standard deviation of the three blanks groups. Results: Statistically high significant difference (p < 0.00) was found between the groups. The marginal gap value of the groups varied Whitepeaks crowns was (105.42 ± 7) μm, which was significantly higher than the two overall mean marginal gap measured for the Imes-icor crowns (59.3 ± 4) μm and Dental direct crowns (54.5 ± 4.9) μm, the Dental direct which was lowers overall mean vertical gap measurement. Conclusions: The marginal gap values of Dental direct crowns is considerably lower than that of Whitepeaks crown, The marginal gap values of all the groups made of monolithic high translucent Y-TZP demonstrated acceptable marginal gaps values.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Engineering
Comparison of Groundwater Quality and Quantity between Al-Rahbah and Al-Haydariyah Regions
...Show More Authors

This study focused on two areas in AL-Najaf city, AL-Ruhbah and Al-Haydariyah regions because of the importance and widespread use of groundwater in these areas. The two areas were compared quantitatively and qualitatively. For the quantitative approach, the GMS software was used in conjunction with the GIS software to simulate the groundwater flow behavior. The solid model for both areas was created, the geological formation was determined, and the hydraulic properties were identified using GMS software. To test the quantity of groundwater in both areas, the wells have been redistributed to a distance of 2000 m between them, and a period of 1000 days was chosen. When a discharge of 10 l/s and operation times of 4, 8, an

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 24 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Experimental Comparison between Classical and Bayes Estimators for the Parameter of Exponential Distribution
...Show More Authors

This paper is interested in comparing the performance of the traditional methods to estimate parameter of exponential distribution (Maximum Likelihood Estimator, Uniformly Minimum Variance Unbiased Estimator) and the Bayes Estimator in the case of data to meet the requirement of exponential distribution and in the case away from the distribution due to the presence of outliers (contaminated values). Through the employment of simulation (Monte Carlo method) and the adoption of the mean square error (MSE) as criterion of statistical comparison between the performance of the three estimators for different sample sizes ranged between small, medium and large        (n=5,10,25,50,100) and different cases (wit

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 27 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Comparison I-V Characteristics of Sb/c-Si and Al/c-Si Junction
...Show More Authors

  Hetero junctions are fabricated by depositing antimony (Sb) and Al films on n-type single crystal(c-Si) wafers by the method of vacuum evaporation with thickness (0.25µm), with rate of deposition equals to 2.77 Ã…/sec, all samples are annealed in a vacuum for one hour at 473K. The tests have shown that all the films have polycrystalline structure for all Sb films. The barrier heights in (Sb/c-Si) junction was found to be equal 0.825eV, but(Al/c-Si) junction ohmic contact. Current-voltage measurements confirm this behaviour.

View Publication Preview PDF
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Comparison of Conventional and Aerobic Iandfill Simulator Reactors (case study; Kirkuk city, Iraq)
...Show More Authors

Under aerobic and anaerobic conditions, two laboratory-scale reactors were operated. Each reactor
was packed with 8.5 kg of shredded synthetic solid waste (less than 5 cm) that was prepared according to an
average composition of domestic solid waste in the city of Kirkuk. Using an air compressor, aerobic
conditions were created in the aerobic reactor. This study shows that the aerobic reactor was more efficient in
COD and BOD5 removal which were 97.88% and 91.25% while in case of anaerobic reactor, they were
66.53%and 19.11%, respectively.

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Jun 25 2023
Journal Name
Tikrit Journal Of Pure Science
Chemical comparison and Trichomes types of Salvia species growing in Anbar Governorate – Iraq
...Show More Authors

The trichomes and chemical composition of three species of the genus Salvia wild-grown (Salvia lanigera, Salvia spinosa) and cultured (Salvia officinalis) were studied in the Anbar governate, the chemical components of the stem and leaves were studied by Gas chromatography–mass spectrometry(GC-MS), in addition to studying the trichomes of the epidermis in the stem and leaves (upper and lower epidermis) by Light microscope. Important differences appeared to us in the chemical study, where it was found that some compounds were found in species without others, which gives them taxonomic importance, also, the trichomes were important in distinguishing the studied species, the species S. spinosa was distinguished by the presence of gla

... Show More
View Publication
Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Engineering And Development
Comparison Study of (urinary & serum) AST Activity from Patients with type 2 diabetes
...Show More Authors

Aspartate aminotransferase was purified from urine and serum of patients with type 2 diabetes in a 2 steps procedure involving dialysis bag and sephadex G-25 gel filtration (column chromatography). The enzyme was purified 346.23 fold with 1467% yield and 3.46 fold with 142.85% yield in urine and serum of patients with type 2 diabetes respectively. The purified enzyme showed single peak. The results of this study revealed that AST activity of type 2 diabetes urine and serum increased significantly (p<0.001) compared with control group.

Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Comparison Study between Iraqi Conditions of Contract and FIDIC Conditions- The Red Book
...Show More Authors

Reconstruction in Iraq requires coherent legitimate frameworks that are able to detail obligations, rights and responsibilities of the parties participating in reconstruction projects, regardless their type or delivery system.
Conditions of Contract can be considered an important component of these frameworks. This paper investigates flexibility and appropriateness of the application of Iraqi conditions of contract in reconstruction projects. These conditions were compared to FIDIC Conditions. The objective wasn't comparing individual clauses, but rather exploring the principles and philosophy laying behind each conditions, and to what extent each conditions care about realizing equity between main contract parties. Validity of applic

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of the Shapiro-Wilk test Jureckova test using simulation and multiple distributions
...Show More Authors

 إن المقصود باختبارات حسن المطابقة هو التحقق من فرضية العدم القائمة على تطابق مشاهدات أية عينة تحت الدراسة لتوزيع احتمالي معين وترد مثل هكذا حالات في التطبيق العملي بكثرة وفي كافة المجالات وعلى الأخص بحوث علم الوراثة والبحوث الطبية والبحوث الحياتية ,عندما اقترح كلا من   Shapiro والعالم Wilk  عام 1965 اختبار حسن المطابقة الحدسي مع معالم القياس
(

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Dec 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison between the effects of Aloe vera and chlorhexidine on clinical periodontal parameters
...Show More Authors

Background: Periodontal diseases are one of the major dental pathologies that affect human populations worldwide at high prevalence rates The term periodontal disease usually refers only to plaque related inflammatory disease of the dental supporting tissues. Mouth rinses which act as an anti-plaque agents mostly used as adjuncts to oral hygiene. Aims of the study: To Estimate and compare the effects of Aloe vera relative to chlorhexidine on the clinical periodontal parameters (plaque index, gingival index, bleeding on probing). Material and method: A total of 44 subjects with plaque-induced gingivitis, baseline of data were collected for (PLI, GI, and BOP) and underwent oral hygiene instruction, scaling and polishing, then divided into:

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
In vitro MIC of Itraconazole Against Different Isolates of Candida albicans
...Show More Authors

In vitro antifungal susceptibility test of itraconazole was carried out against 38 isolates from nails, skin, oral cavity, vagina and wounds, This study was done in Ramadi Teaching Hospital in period from January to August 2010. According to the National Committee for Clinical Laboratory Standard (NCCLS ) M 27- A by using the broth dilution method. Inoculum size was 1-5X103 CFU/ ml, while final concentrations of itraconazole ranged from 0.025 – 6.4 μg / ml by using RPMI – 1640 broth media and the fungus was incubated at 35 oC.  No resistant stain was recorded. MIC ranged from 0.05 – 6.4 μg / ml and the Mean ± SEM was 0.89 ± 0.28. MIC for nail isolates was 0.05 –

... Show More
View Publication Preview PDF
Crossref