Preferred Language
Articles
/
jbcd-1858
A Comparison of Vertical Marginal Fit of different Brands of Translucent Zirconia Crown Restorations
...Show More Authors

Background: As the development of zirconia crown using CAD/CAM technology, the usage of full zirconia crown is gradually increased. The aim of this in-vitro study was to evaluate and contrast the vertical marginal fit of single all-ceramic translucent zirconia crowns constructed from different brands translucent zirconia blanks. Materials and Methods: An acrylic resin model of a left maxillary premolar was prepared all around the tooth with (1 mm) depth and 3D scanning to get fifteen STL files, then distributed into three groups (Imes-icor, Whitepeaks and Dental direct), 3D scanning and milling machine by Imes-icor CAD/CAM devise. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) using a light microscope at a magnification of x100. One-way ANOVA, LSD tests were performed to determine the mean and standard deviation of the three blanks groups. Results: Statistically high significant difference (p < 0.00) was found between the groups. The marginal gap value of the groups varied Whitepeaks crowns was (105.42 ± 7) μm, which was significantly higher than the two overall mean marginal gap measured for the Imes-icor crowns (59.3 ± 4) μm and Dental direct crowns (54.5 ± 4.9) μm, the Dental direct which was lowers overall mean vertical gap measurement. Conclusions: The marginal gap values of Dental direct crowns is considerably lower than that of Whitepeaks crown, The marginal gap values of all the groups made of monolithic high translucent Y-TZP demonstrated acceptable marginal gaps values.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparison Study for The Performance of Polyethersulfone Ultrafiltration Mixed Matrix Membranes in The Removal of Heavy Metal Ions from Aqueous Solutions
...Show More Authors

Polyethersulfone (PES) ultrafiltration membrane blending NaX zeolite crystals as a hydrophilic additive was examined for zinc (II) and lead ions Pb (II) removal from aqueous solutions. The effect of NaX zeolite content on the permeation flux and removal efficiency was studied. The results showed that adding zeolite to the polymer matrix enhanced the permeation flux. The permeation flux of all the zeolite/PES matrix membranes was higher than the pristine membrane. No significant improvement was observed in the removal of Zn (II) ions using all prepared membranes as the removal percentage did not raise above 29.2%. However, the removal percentage of Pb (II) ions was enhanced to 97% using a membrane containing 0.9%wt. zeolite. Also, it was

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Al-kindy College Medical Journal
A Comparison between High Ablative Versus Usual Dosages of Iodine-131 in Inducing Hypothyroidism After One Year of Therapy in Hyperthyroid Patients
...Show More Authors

Background: Radioactive iodine-131 therapy is highly effective in treating patients with hyperthyroidism. An ablative dose is preferred by a number of endocrinologists, and, a fixed dose protocol seems to be better than a calculated dose in real practice.

Objective: To check for hypothyroidism in hyperthyroid patients one year after RAI therapy, comparing between the results of high ablative versus usual dosages of RAI-131.

 Methods:  This study included 174 hyperthyroid patients, 101 males and 73 females, divided into 2 groups, the first consisted of 162 patients given a usual fixed dose of RAI while the second consisted of 12 patients given a high fixed ablati

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Aug 28 2020
Journal Name
Iraqi Journal Of Science
A comparison of the Effects of Lemon Peel -Silver Nanoparticles Versus Brand Toothpastes and Mouthwashes on Staphylococcus Spp. Isolated From Teeth Caries
...Show More Authors

Thirty one  samples of gum swabs were collected from patients with tooth caries (5-30 years old)  from the College of Science (Biology department )- University of Baghdad- Iraq for the period from October 2018 to December 2018. , The samples were transported, after inoculation in a transport media (nutrient broth), to the laboratory of the College of Science and then cultured on mannitol salt agar and  blood agar). The isolates belonging to Staphylococcus spp. were identified by biochemical tests and Vitek 2 compact system, while the more antibiotic resistant isolates were identified by using Polymerase Chain Reaction(ï´¾PCR)  and sequencing of 16SrRNA . The results showed sharp UV absorption peaks at 330 - 340nm and AFM at 5

... Show More
Preview PDF
Scopus (21)
Crossref (12)
Scopus Crossref
Publication Date
Fri Oct 01 2021
Monitoring and controlling the speed and direction of a DC motor through FPGA and comparison of FPGA for speed and performance optimization
...Show More Authors

<span lang="EN-US">We are living in the 21<sup>st</sup> century, an era of acquiring necessity in one click. As we, all know that technology is continuously reviving to stay ahead of advancements taking place in this world of making things easier for mankind. Technology has been putting his part in introducing different projects as we have used the field programmable gate arrays (FPGAs) development board of low cost and programmable logic done by the new evolvable cyclone software is optimized for specific energy based on Altera Cyclone II (EP2C5T144) through which we can control the speed of any electronic device or any Motor Control IP product targeted for the fan and pump. Altera Cyclone FPGAs’ is a board thro

... Show More
Scopus (17)
Crossref (7)
Scopus Crossref
Publication Date
Tue Dec 13 2022
Journal Name
International Information And Engineering Technology Association
Countermeasure of Riverbanks Local Scour and Deposition Using Different Shapes of Multiple Groynes with Different Spacing
...Show More Authors

In current study a computation fluid dynamic (CFD) technique was used to investigate the effect of groynes shape and spacing on the scour pattern and the maximum scour depth in open channel flow. CFD model have been validated throughout comparing the numerical results with three previous experimental studies for a single groyne located in open channel with three different shapes (L, quadrant, and parabola shapes). The comparison revealed very good agreement between numerical results of the maximum scour depth with the results of all experimental models. Moreover, investigations of the effect of multi-groynes (three groynes and four groynes) arranged in parallel with constant spacing and also with variable spacing have been done, the

... Show More
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Engineering
A Review on Expansive Soils Stabilized with Different Pozzolanic Materials
...Show More Authors

Soils that cause effective damages to engineer structures (such as pavement and foundation) are called problematic or difficult soils (include collapsible soil, expansive soil, etc.). These damages occur due to poor or unfavorited engineering properties, such as low shear strength, high compressibility, high volume changes, etc. In the case of expansive soil, the problem of the shrink-swell phenomenon, when the soil reacts with water, is more pronounced. To overcome such problems, soils can be treated or stabilized with many stabilization ways (mechanical, chemical, etc.). Such ways can amend the unfavorited soil properties. In this review, the pozzolanic materials have been selected to be presented and discussed as chem

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (17)
Scopus Crossref
Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparative Study of the Influence of Different Types of Polymers on Viscosity Index and Pour Point of Iraqi Base Oils
...Show More Authors

In this study, the effects of blending the un-branched acrylate polymer known as Poly (n-decyl acrylate), and the branched acrylate polymer known as Poly (iso-octyl acrylate), on the viscosity index (VI), and the pour point of the Iraqi base stocks 40, and 60 respectively, were investigated. Toluene was used as a carrier solvent for both polymer types. The improvement level of oils (VI, & pour point) gained by blending the oil with the acrylate derived polymers was compared with the values of (VI, and pour point) gained by blending the oil with a commercial viscosity index, and pour point improver. The commercial lubricant additive was purchased and used by Al-Daura Refineries. It consisted of an un-known olefin copolymer dissolved i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
A Stereomicroscopic Analysis of Dentinal Micro Cracks after Root Canal Preparation Using Four Different Rotary Instruments.
...Show More Authors

A variety of single-engine driven files and inematics have been introduced to improve the clinical performance of NiTi rotary files. The purpose of this in vitro study was to measure and compare the incidence of dentinal defects after root canal preparation with different single file systems.

View Publication
Crossref
Publication Date
Sun May 03 2020
Journal Name
Journal Of Advanced Laboratory Research In Biology
Hepatitis B Virus (HBV): A Review on its Prevalence and Infection in different areas of Iraq
...Show More Authors

View Publication
Publication Date
Thu Jun 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Fracture strength of laminate veneers using different restorative materials and techniques (A comparative in vitro stuy)
...Show More Authors

Background: Esthetic correction represents one of the clinical conditions that required the use of laminate veneers in premolars region. Aim of the study: The purpose of this study was to evaluate the fracture strength of the laminate veneers in maxillary first premolars, fabricated from either composite (direct and indirect techniques) or ceramic CAD/CAM blocks. Materials and Methods: Fifty sound human maxillary premolar teeth were used in this in vitro study. Teeth were divided randomly into one control group and four experimental groups of ten teeth each; Group A: Restored with direct composite veneer (Filtek Z250 XT), Group B: Restored with indirect composite veneers (Filtek Z250 XT), Group C: Restored with lithium disilicate ceramic CA

... Show More
View Publication Preview PDF