Preferred Language
Articles
/
jbcd-1857
Fracture Resistance of Endodontically Treated Premolar Teeth with Extensive MOD Cavities Restored with Different Bulk Fill Composite Restorations (An In vitro Study)
...Show More Authors

Background: The present in-vitro study was undertaken to evaluate and compare fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different bulk fill composite restorations (EverX posterior, Alert, Tetric EvoCeram Bulk Fill, and SDR). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Forty-eight human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into six groups of eight teeth each (n=8): (Group 1) intact control group, (Group 2) unrestored teeth with endodontic treatment, (Group 3) restored with (TetricEvoCeram Bulk Fill), (Group 4) restored with SDR bulk-fill flowable composite, (Group 5) restored with EverX Posterior composite and (Group 6) restored with Alert composite. . All specimens were subjected to compressive axial loading until fracture in a universal testing machine. The data were statistically analyzed using one-way ANOVA test and LSD test. Macroscopic fracture type were observed and classified into favorable and unfavorable. Specimens in groups 3, 4, 5 and 6 were examined by stereomicroscope at a magnification of 20× to evaluate the mode of failure into adhesive, cohesive or mixed. Results: The mean fracture load was (1.2505Kn) for group 1, (0.371Kn) for group 2, (0.512 Kn) for group 3, (0.6435 Kn) for group 4, (0.608 Kn) for group 5, and (0.8315) for group 6. Using one way ANOVA test a highly significant difference (P < 0.01) were found among all groups. The use of Alert composite (which contain micro glass fiber) improved the fracture resistance significantly in comparison to other groups. SDR bulk-fill flowable composite showed better improvement in fracture resistance but with no significant differences in comparison to EverX composite restoration (which contain Short E-glass fiber filler). The type of failure was unfavorable for all the restored groups. Conclusion: All experimental composite restorations showed significant improvement in the resistance to cuspal fracture in comparison to unrestored one (group 2). However, under the conditions of this study, direct composite restorations should be considered as a valid interim restoration for weakened endodontically treated teeth before cuspal coverage can be provided.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of the Solubility of Four Endodontic Sealers in Different Solvents (An In Vitro Study)
...Show More Authors

Background: Complete removal of filling material from the root canal is an essential requirement for endodontic retreatment. The purpose of the present study is to evaluate and compare the dissolving capabilities of various solvents (Xylene, Eugenate Desobturator, Eucalyptol, EDTA and Distilled water (as a control)) on four different types of sealer (Endofill, Apexit Plus, AH Plus and EndoSequence bioceramic sealer). Materials and method: Eighty samples of each sealer were prepared according to the manufacturers' instructions and then divided into ten groups (of 8 samples) for immersion in the respective solvents for 2 and 5 min immersion periods. Each sealer specimen was weighed to obtain its initial mass. The specimens were immersed in

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Impact of different types of storage media on enamel surface roughness and granularity distribution of avulsed teeth (In vitro study)
...Show More Authors

Background: To investigate the effect of different types of storage media on enamel surface microstructure of avulsed teeth by using atomic force microscope.Materials and methods : Twelve teeth blocks from freshly extracted premolars for orthodontic treatment were selected . The study samples were divided into three groups according to type of storage media :A-egg white , B- probiotic yogurt , and C-bovine milk . All the samples were examined for changes in surface roughness and surface granularity distribution  using atomic force microscope, at two periods: baseline, and after 8 hours of immersing in the three types of storage media. Results: Milk group had showed a significant increase in the mean of the  roughness values at

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Aug 17 2022
Journal Name
Aip Conference Proceedings
Study of some physical and mechanical properties of paper sheets treated with different polymeric adhesive solution
...Show More Authors

The present researchers are trying to enhance the properties of paper sheet that used widely in many fields such as printing and packaging. The enhancement of paper quality is also possible to preserve paper documents of all kinds, as they are the true record, full of the history, achievements of the human being and the intellectual and cultural of the country. It is possible to improve its physical and mechanical properties and preserve them from damage through the use of some solutions of polymeric adhesives, which act as protective barriers against water and moisture penetration. The paper also has the advantage of porosity, which has been overcome by using three types of polymeric adhesives (Nitro Cellulose, Polyvinyl alcohol acetate, a

... Show More
Scopus (1)
Scopus
Publication Date
Wed Apr 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Fracture strength of laminate veneers using different restorative materials and techniques (A comparative in vitro stuy)
...Show More Authors

Background: Esthetic correction represents one of the clinical conditions that required the use of laminate veneers in premolars region. Aim of the study: The purpose of this study was to evaluate the fracture strength of the laminate veneers in maxillary first premolars, fabricated from either composite (direct and indirect techniques) or ceramic CAD/CAM blocks. Materials and Methods: Fifty sound human maxillary premolar teeth were used in this in vitro study. Teeth were divided randomly into one control group and four experimental groups of ten teeth each; Group A: Restored with direct composite veneer (Filtek Z250 XT), Group B: Restored with indirect composite veneers (Filtek Z250 XT), Group C: Restored with lithium disilicate ceramic CA

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Dental Hypotheses
Effect of Surface Treatments with Plasma and Chemical Bond on Shear Bond Strength of Acrylic Denture Teeth to Flexible and Heat-Cured Denture Base Material: An In Vitro Study
...Show More Authors

Introduction: We aimed to evaluate the shear bond strength of acrylic denture teeth to flexible and heat-cured denture base material after surface treatments with argon plasma, chemical bonding agent (PALFIQUE universal), and combination. Methods: A total of 80 incisor acrylic denture teeth were treated with a argonplasma, chemical bond (PALFIQUE universal bond), and a combination with 10 samples for each group. The neck (gingival portion) of teeth was cut at a 45° angle, and the teeth were attached to heat-cured acrylic resin and flexible denture base material. All the specimens were stored in artificial saliva for 7 days in an incubator (37 °C). A shear

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the therm

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of a novel coating material on the microleakage of glass hybrid restoration in primary teeth – An in vitro study
...Show More Authors

Background: Glass ionomer restorations are widely employed in the field of pediatric dentistry. There is a constant demand for a durable restoration that remains functional until exfoliation. This study aimed to measure and compare the effect of a novel coating material (EQUIA Forte Coat) on the microleakage of glass hybrid restoration (EQUIA Forte HT) in primary teeth. Material and method: Thirty cavitated (class-II) primary molars were allocated randomly into two groups based on the coat application; uncoated (control) and coated group (experimental). Cavities were prepared by the use of a ceramic bur (CeraBur) and restored with EQUIA Forte HT with or without applying a protective coat (EQUIA Forte Coat). Samples went through the

... Show More
Crossref (1)
Crossref
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Color Stability of Different Aesthetic Archwires after Immersion into Different Types of Mouthwashes(An In Vitro Study)
...Show More Authors

Background: Because of the demands for aesthetic orthodontic appliances have increased, aesthetic archwires have been widely used to meet patient's aesthetic needs. The color stability of aesthetic archwires is clinically important, any staining or discoloration will affect patient’s acceptance and satisfaction. This study was designed to evaluate the color stability of different types of aesthetic archwires after immersion into different types of mouth washes. Materials and methods: Four brands of nickel titanium coated aesthetic arch wires: Epoxy coated (Orthotechnology and G&H) and Teflon coated (Dany and Hubit) were evaluated after 1 week, 3 weeks and 6 weeks of immersion into two types of mouthwashes (Listerine with alcohol and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Australian Dental Journal
Debonding of LDSVs utilising Er,Cr:YSGG laser irradiation with fractional technique: an in vitro study
...Show More Authors

Scopus (2)
Scopus
Publication Date
Wed Apr 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of cavity design for cusp coverage on fracture strength of weakened maxillary first premolars using two esthetic restorative systems (CAD/CAM hybrid ceramic and nanohybrid composite) (An in vitro study)
...Show More Authors

Background: Maxillary first premolar with wide MOD cavity more susceptible to fracture. The aim of this study was to assess the influence of cavity design for cusp coverage on the fracture resistance of weakened maxillary first premolar restored with CAD/CAM hybrid ceramic versus nanohybide composite. Materials and Methods: Fifty six intact maxillary first premolars of approximately comparable sizes were divided into seven groups eight for each: Group A: Intact teeth (control group); Group B: teeth prepared for MOD inlay; Group C: teeth prepared for MOD onlay covering the lingual cusp; Group D: teeth prepared for MOD covering buccal and lingual cusps ,the previous three groups indirectly restored with nanohybrid composite (3M ESPE Z 250 X

... Show More
View Publication Preview PDF