Preferred Language
Articles
/
jbcd-1857
Fracture Resistance of Endodontically Treated Premolar Teeth with Extensive MOD Cavities Restored with Different Bulk Fill Composite Restorations (An In vitro Study)
...Show More Authors

Background: The present in-vitro study was undertaken to evaluate and compare fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different bulk fill composite restorations (EverX posterior, Alert, Tetric EvoCeram Bulk Fill, and SDR). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Forty-eight human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into six groups of eight teeth each (n=8): (Group 1) intact control group, (Group 2) unrestored teeth with endodontic treatment, (Group 3) restored with (TetricEvoCeram Bulk Fill), (Group 4) restored with SDR bulk-fill flowable composite, (Group 5) restored with EverX Posterior composite and (Group 6) restored with Alert composite. . All specimens were subjected to compressive axial loading until fracture in a universal testing machine. The data were statistically analyzed using one-way ANOVA test and LSD test. Macroscopic fracture type were observed and classified into favorable and unfavorable. Specimens in groups 3, 4, 5 and 6 were examined by stereomicroscope at a magnification of 20× to evaluate the mode of failure into adhesive, cohesive or mixed. Results: The mean fracture load was (1.2505Kn) for group 1, (0.371Kn) for group 2, (0.512 Kn) for group 3, (0.6435 Kn) for group 4, (0.608 Kn) for group 5, and (0.8315) for group 6. Using one way ANOVA test a highly significant difference (P < 0.01) were found among all groups. The use of Alert composite (which contain micro glass fiber) improved the fracture resistance significantly in comparison to other groups. SDR bulk-fill flowable composite showed better improvement in fracture resistance but with no significant differences in comparison to EverX composite restoration (which contain Short E-glass fiber filler). The type of failure was unfavorable for all the restored groups. Conclusion: All experimental composite restorations showed significant improvement in the resistance to cuspal fracture in comparison to unrestored one (group 2). However, under the conditions of this study, direct composite restorations should be considered as a valid interim restoration for weakened endodontically treated teeth before cuspal coverage can be provided.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 13 2018
Journal Name
Mustansiria Dental Journal
Dimensional stability of heat-activated acrylic resin at different time intervals by different flask cooling methods
...Show More Authors

This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an

... Show More
Preview PDF
Publication Date
Fri Apr 01 2022
Journal Name
Baghdad Science Journal
Iron (II) Determination in Lipstick Samples using Spectrophotometric and Microfluidic Paper-based Analytical Device (µPADs) Platform via Complexation Reaction with Iron Chelator 1, 10-phenanthroline: A Comparative Study
...Show More Authors

This study was undertaken to introduce a fast, accurate, selective, simple and environment-friendly colorimetric method to determine iron (II) concentration in different lipstick brands imported or manufactured locally in Baghdad, Iraq. The samples were collected from 500-Iraqi dinars stores to establish routine tests using the spectrophotometric method and compared with a new microfluidic paper-based analytical device (µPAD) platform as an alternative to cost-effective conventional instrumentation such as Atomic Absorption Spectroscopy (AAS). This method depends on the reaction between iron (II) with iron(II) selective chelator 1, 10-phenanthroline(phen) in the presence of reducing agent hydroxylamine (HOA) and sodium acetate (NaOAc) b

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
Diagnostic Accuracy of Different Radiological Investigations in the Diagnosis of Perforated Duodenal Ulcer
...Show More Authors

Background; Perforated duodenal ulcer (PDU) is a common surgical emergency that is associated with high mortality and morbidity. Early diagnosis and prompt surgical treatment is required to prevent grave complications.
Objective; The study was designed to evaluate the diagnostic accuracy of different radiological investigations in the diagnosis of perforated duodenal ulcer.
Methods; A prospective study of 185 pts with PDU at al kindy teaching hospital, Baghdad, Iraq from June 2008- august 2010. patients were examined clinically and investigated by blood test, chest x ray, plain X ray of the abdomen. Ultrasonography (U/S) and CT scanning done for those patients with negative X- ray finding. Resuscitation by intravenous fluid and ant

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Different Electrodes Connections in Electrocoagulation of Synthetic Blow down Water of Cooling Tower
...Show More Authors

In this research, the performance of electrocoagulation (EC) using aluminum (Al) electrodes with   Monopolar- parallel (MP-P), and bipolar - series (BP-S) arrangement for simultaneous removal of dissolved silica, and hardness ions (calcium, and magnesium) from synthetic blowdown water of cooling tower were investigated. The effects of current density, initial pH and time of electrolysis on the removal efficiency were studied in a batch stirred unit to find out the best-operating conditions. The obtained results for each target species are evidence that BP-S approach is the best for both electrodes configuration operated at a Current density of 1mA/cm2 through 30 min of treatment and pH=10 with the removal of

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Oct 01 2008
Journal Name
Saudi Medical Journal
The therapeutic and prophylactic role of oral zinc sulfate in management of recurrent aphthous stomatitis (ras) in comparison with dapsone.
...Show More Authors

KE Sharquie, RA Najim, RK Al-Hayani, AA Al-Nuaimy, DM Maroof, Saudi medical journal, 2008 - Cited by 74

View Publication
Publication Date
Fri Nov 02 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Nursing Knowledge and Practices Concerning Nursing Care of Patient with Skin Traction in Orthopedic Units in Kurdistan Region
...Show More Authors

Objective: The study aimed to evaluate knowledge and practices of nursing staff at the orthopedic units
regarding the existing care of patient with skin traction.
Methodology: The sample consists of (40) nurses, (20) of them from Emergency Teaching Hospital in Duhok
and the other (20) of them from Erbil Teaching Hospital in Erbil from 1st Dec. 2004 to the end of June 2005 in
Kurdistan Region.
Two instruments were constructed to evaluate knowledge and practices. Evaluation of knowledge was done by
using of multiple choice questions composed of (25) questions, and evaluation of practice was done by using the
observational check list which consist of four main category (pre skin traction, during skin traction, post skin

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Journal Of Medicine And Life
Evaluating the effect of ursodeoxycholic acid (UDCA) in comparison with dexamethasone and diclofenac in a rat model of rheumatoid arthritis
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Iranian Journal Of Veterinary Science And Technology
Investigation of bacterial contamination with Klebsilla and E. coli in the prepucal cavity of pubertal and adult age in caprine
...Show More Authors

View Publication Preview PDF
Scopus (3)
Scopus
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
The quality of the auditor's report in the local environment in compliance with the requirements of the ISA 701 standard
...Show More Authors

The research aims to demonstrate the quality of the auditor’s report by analyzing a number of models represented by the auditor’s report based on the Iraqi audit evidence and the auditor’s report in light of the application of international auditing standards for the report and the auditor’s report in light of the application of the International Auditing Standard 701, in addition to explaining the impact of applying the International Auditing Standard 701. International Auditing 701 in enhancing the quality of the auditor's report, and in order to reach these goals, a comparison was made on international experiences before and after the application of the standard in addition to the results of the questionnaire distribut

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 02 2023
Journal Name
International Journal Of Applied Engineering & Technology
ASSESSING THE CONCENTRATIONS OF SOME HEAVY METALS IN BLOOD SAMPLES OF CHILDREN DIAGNOSED WITH AUTISM SPECTRUM DISORDERS IN BAGHDAD CITY
...Show More Authors