Preferred Language
Articles
/
jbcd-1857
Fracture Resistance of Endodontically Treated Premolar Teeth with Extensive MOD Cavities Restored with Different Bulk Fill Composite Restorations (An In vitro Study)
...Show More Authors

Background: The present in-vitro study was undertaken to evaluate and compare fracture resistance of weakened endodontically treated premolars with class II MOD cavities restored with different bulk fill composite restorations (EverX posterior, Alert, Tetric EvoCeram Bulk Fill, and SDR). The type and mode of fracture were also assessed for all the experimental groups. Materials and Method: Forty-eight human adult maxillary premolar teeth were selected for this study. Standardized extensive class II MOD cavities with endodontic treatment were prepared for all teeth, except those that were saved as intact control. The teeth were divided into six groups of eight teeth each (n=8): (Group 1) intact control group, (Group 2) unrestored teeth with endodontic treatment, (Group 3) restored with (TetricEvoCeram Bulk Fill), (Group 4) restored with SDR bulk-fill flowable composite, (Group 5) restored with EverX Posterior composite and (Group 6) restored with Alert composite. . All specimens were subjected to compressive axial loading until fracture in a universal testing machine. The data were statistically analyzed using one-way ANOVA test and LSD test. Macroscopic fracture type were observed and classified into favorable and unfavorable. Specimens in groups 3, 4, 5 and 6 were examined by stereomicroscope at a magnification of 20× to evaluate the mode of failure into adhesive, cohesive or mixed. Results: The mean fracture load was (1.2505Kn) for group 1, (0.371Kn) for group 2, (0.512 Kn) for group 3, (0.6435 Kn) for group 4, (0.608 Kn) for group 5, and (0.8315) for group 6. Using one way ANOVA test a highly significant difference (P < 0.01) were found among all groups. The use of Alert composite (which contain micro glass fiber) improved the fracture resistance significantly in comparison to other groups. SDR bulk-fill flowable composite showed better improvement in fracture resistance but with no significant differences in comparison to EverX composite restoration (which contain Short E-glass fiber filler). The type of failure was unfavorable for all the restored groups. Conclusion: All experimental composite restorations showed significant improvement in the resistance to cuspal fracture in comparison to unrestored one (group 2). However, under the conditions of this study, direct composite restorations should be considered as a valid interim restoration for weakened endodontically treated teeth before cuspal coverage can be provided.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Apr 21 2022
Journal Name
Neuroquantology
New Record of the Species Margarinotus punctiventer, Marseul, 1854 (Histeridae, Coleoptera) with Forensic Study from Sulaymaniyah, City Iraq.
...Show More Authors

Publication Date
Wed Nov 23 2022
Journal Name
Neuroquantology2
New record of the species Hydroteae crytoneurina (Zetterstdt, 1845) (Diptera, Muscidae) with forensic study from Sulaymaniyah City-Iraq
...Show More Authors

Publication Date
Thu Nov 20 2025
Journal Name
Mustansiria Dental Journal
Soft tissue measurements of Iraqi individuals with Cl I and Cl III skeletal pattern: a comparative cephalometric study
...Show More Authors

View Publication
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Synthesis and Spectroscopic Study of 3-Hydroxy-2-(3-(4- Nitrobenzoyl) Thiouriedo) Propanoic Acid with their Metal Complexes
...Show More Authors

A new ligand 3-hydroxy-2-(3-(4-nitrobenzoyl) thiouriedo) propanoic acid (NTP) where synthesized by reaction of 4-nitro benzoyl isothiocyanate with serine amino acid. The ligand was characterized by FT-IR, NMR spectra and the elemental analysis. The transition metal complexes of this ligand where synthesize and characterized by UV-Visible spectra, FT-IR, magnetic suscpility, conductively measurement, The general formula [M (NTP) 2] where M+2= (Mn, Co, Ni, Cu, Zn, Cd, Hg,), the form of molecular for these complexes as tetrahedral except Cu has square planer.

Publication Date
Thu Dec 24 2020
Journal Name
Advances In Civil Engineering
Analytical study on torsional behavior of concrete beams strengthened with fiber reinforced polymer laminates using softened truss model
...Show More Authors

This study aimed at evaluating the torsional capacity of reinforced concrete (RC) beams externally wrapped with fiber reinforced polymer (FRP) materials. An analytical model was described and used as a new computational procedure based on the softened truss model (STM) to predict the torsional behavior of RC beams strengthened with FRP. The proposed analytical model was validated with the existing experimental data for rectangular sections strengthened with FRP materials and considering torque-twist relationship and crack pattern at failure. The confined concrete behavior, in the case of FRP wrapping, was considered in the constitutive laws of concrete in the model. Then, an efficient algorithm was developed in MATLAB environment t

... Show More
Scopus (14)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Nov 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The role of 3-dimensional multi-detector computed tomography in the diagnosis of Eagle’s syndrome and correlation with severe headache and migraine (Iraqi study)
...Show More Authors

Background: The styloid process is a cylindrical bone (protrusion). It situated above the common carotid artery between the external and internal branches immediately proximal to the internal jugular vein and facial nerves. The styloid process varies in length also it may be absent as well as elongated. Classically, an elongated styloid process and calcified of stylohyoid ligament causes Eagle’s syndrome. The aim of this study was to examine the styloid process using 3 dimensional multi-detector computed tomography (3D-MDCT) to detect the presence of Eagle’s syndrome that causes severe headache and migraine. Materials and methods: One hundred patients with severe headache and migraine were exposed to 3D- multi-detector CT with special

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
The Effect of Age and Gender on Fetuin-A and Some Biochemical parameters in Blood Sera of Iraqi patients with T2DM: A comparative study
...Show More Authors

The serum protein test includes measurement of the level of total protein(albumin, globulin). Fetuin-A is a blood protein made in liver. It can inhibit insulin receptor, enhance insulin sensitivity and make the individuals more likely to develop type 2 diabetes, then disorder in lipid profile (Total cholesterol(TC), low density lipoprotein cholesterol (LDL-c), high density lipoprotein cholesterol (HDL-c), Triglyceride(TG) and very low density lipoprotein cholesterol (VLDL-c) . To evaluate Fetuin-A, total protein, albumin, globulin, HbAlc and lipid profile in 200 adult and elderly Iraqi patients with type 2 Diabetes Mellitus were taken and compare them with 200 subjects as a healthy control. The laboratory analysis(for patients and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2010
Journal Name
Iraqi Journal Of Science
IMMUNONOLOGICAL EVALUATION AND ACUTE TOXICITY STUDY WITH FERTILITY EXAMINATION FOR THE EFFECT OF AQUEOUS EXTRACT FROM DRIED FRUITS OF Piper nigrum L. IN MICE
...Show More Authors

The research work was conducted to investigate the effect of oral administration of water extract of black pepper at doses of (1, 5) mg/kg body weight for two weeks daily by determining the genotoxic effect (mitotic index), evaluation of immunological effect (IgG, IgM, IgA, C3, C4) and measuring fertility hormones (follicles stimulation hormone/FSH, lutenising hormone/LH) levels with histopathological examinations of female albino swiss mice ovaries in comparison with control (normal saline). A clear effect in increasing mitotic activity was reveled for both doses in comparison with control. Results also showed a significant increase in the value of the all immunological parameters at both doses in comparison with control. Also obvious rais

... Show More
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Precision of pachymetric measurements with Scheimpflug –Placido disc cornealTopography and comparison of these measurements with ultrasonic pachymetry
...Show More Authors

Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtain

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 02 2020
Journal Name
International Journal Of Pharmaceutical Research
Etodolac Topical Spray Films, Development, Characterization and In-Vitro Evaluation
...Show More Authors

View Publication
Scopus (8)
Crossref (3)
Scopus Crossref