Preferred Language
Articles
/
jbcd-1856
Evaluation of the effect of preheating on micro leakage of Class II composites Restoration (A comparative in vitro study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt.  in Class II cavity preparation .

Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used    group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of  composite: Group A1 Teeth are restored by composite at  room temperature(24±1ËšC), A2 Teeth are restored by same composite at preheated temperature(54±1ËšC). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated.

Results: The greater scores of micro leakage mentioned in Group A( Z250 micro hybrid) in cervical margin while in Group B( Z250xt Nano hybrid) and  Group C (Z350xt nanocomposite) have least score of micro leakage especially in occlusal margin.

Conclusions: The scores of micro leakage for all groups varied with different material, margin and temperature. Generally, preheating decreased micro leakage  in all groups of composites ,but Preheating decreased micro leakage effectively in Z250 micro hybrid more than Z250xt Nano hybrid and Z350xt nanocomposite micro leakage .

Crossref
View Publication
Publication Date
Sat Dec 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An in vitro evaluation of fit of the crowns fabricated by zirconium oxide-based ceramic CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles
...Show More Authors

Background: The objective of this in vitro study was to evaluate the vertical marginal fit of crowns fabricated with ZrO2 CAD/CAM, before and after porcelain firing cycles and after glaze cycles. Materials and Methods: An acrylic resin model of a left maxillary first molar was prepared and duplicated to have Nickel-Chromium master die. Ten die stone dies were sent to the CAD/CAM (Amann Girrbach) for crowns fabrication. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) before (Time 0) and after porcelain firing cycles (Time 1) and after glaze cycles (Time 2) using a light microscope at a magnification of ×100. One way ANOVA LSD tests were performed to determine wh

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 20 2025
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis
...Show More Authors

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Iraqi Journal Of Physics
Studying the Effect of Initial Conditions and System Parameters on the Behavior of a Chaotic Duffing System
...Show More Authors

This work presents a five-period chaotic system called the Duffing system, in which the effect of changing the initial conditions and system parameters d, g and w, on the behavior of the chaotic system, is studied. This work provides a complete analysis of system properties such as time series, attractors, and Fast Fourier Transformation Spectrum (FFT). The system shows periodic behavior when the initial conditions xi and yi equal 0.8 and 0, respectively, then the system becomes quasi-chaotic when the initial conditions xi and yi equal 0 and 0, and when the system parameters d, g and w equal 0.02, 8 and 0.09. Finally, the system exhibits hyperchaotic behavior at the first two conditions, 0 and 0, and the bandwidth of the chaotic

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Diyala Journal For Pure Sciences
Synthesis and Biological Studies of Co(II),Ni(II),Cu(II) and Zn(II)Complexes with New Compound N-[(2,3-dioxoindolin-1-yl)-Nmethylbenzamide].
...Show More Authors

The N-[(2,3-dioxoindolin-1-yl)-N-methylbenzamide] was prepared by the reaction of acetanilide with isatin then in presence of added paraformaldehyde, the prepared ligand was identified by microelemental analysis, FT.IR and UV-Vis spectroscopic techniques. Treatment of the prepared ligand with the following selected metal ions (CoII, NiII, CuII and ZnII) in aqueous ethanol with a 1:2 M:L ratio, yielded a series of complexes of the general formula [M(L)2Cl2]. The prepared complexes were characterized using flame atomic absorption, (C.H.N) analysis, FT.IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. Chloride ion content was also evaluated by (Mohr method). From the obtained data the octahed

... Show More
Publication Date
Tue May 01 2018
Journal Name
Journal Of Physics: Conference Series
Synthesis, Characterization and Antibacterial Activity of 1,4-di[ aminomethylene carboxyl] phenylene (H2L) and its Complexes Co(II), Cu (II), Zn(II) and Cd (II)
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Tue Jul 13 2010
Journal Name
Journal Of Kerbala University
Synthesis and Characterization of Fe(II),Cd(II),Hg(II) and Ag (I) complexes with 2-Thiotolylurea Ligand
...Show More Authors

Complexes reaction of Fe+2, Cd+2, Hg+2 and Ag+ with the 2-thiotolylurea were prepared in ethanolic medium with the (1:1) M:L ratio yielded a series of neutral complexes. The prepared complexes were characterized using flame atomic absorption, micoelemental analysis (C.H.N), chloride content (Mohr Method) , FT.IR and UV-Vis spectroscopic, as well as magnetic susceptibility and conductivity measurement. From the above data, the proposed molecular structure for Fe+2, Cd+2 and Hg+2 complexes are tetrahedral geometry while Ag+ complex is trigonal structure.

Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Single Dose Antibiotic Prophylaxis in Outpatient Oral Surgery Comparative Study
...Show More Authors

         It is clear that correct application of antibiotic prophylaxis can reduce the incidence of infection  resulting from the bacterial  inoculation in a variety of clinical situations; it cannot   prevent  all  infections  any  more  than it  can   eliminate  all  established infections. Optimum  antibiotic   prophylaxis  depends on:  rational  selection  of the drug(s),  adequate  concentrations  of the  drug  in  the  tissues that  are at risk, and attention to  timing  of  administration.  Moreover,  the  risk  of

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn: 1683 - 3597 , E-issn : 2521 - 3512)
Single Dose Antibiotic Prophylaxis in Outpatient Oral Surgery Comparative Study
...Show More Authors

         It is clear that correct application of antibiotic prophylaxis can reduce the incidence of infection  resulting from the bacterial  inoculation in a variety of clinical situations; it cannot   prevent  all  infections  any  more  than it  can   eliminate  all  established infections. Optimum  antibiotic   prophylaxis  depends on:  rational  selection  of the drug(s),  adequate  concentrations  of the  drug  in  the  tissues that  are at risk, and attention to  timing  of  administration.  Moreover,  the  risk  of  infection  in  some situations  does not outweigh  the risks which  attend the administration of even the safest antibiotic drug. The aim of this study was to comp

... Show More
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Apr 09 2022
Journal Name
Engineering, Technology & Applied Science Research
The Mechanical Properties of Fly Ash and Slag Geopolymer Mortar with Micro Steel Fibers
...Show More Authors

In this study, experimental mortar combinations with 1% micro steel fibers, were examined to create geopolymer mortars. To test the effect of the fibers on the mortar's resistance, the geopolymer mortar was designed with various proportions of more environmentally friendly materials fly ash and slag. The percentage of fly ash by weight was 50, 60, and 70% of the slag. The best results were obtained when a 50:50 ratio of fly ash and slag were mixed with 1% micro steel fibers. The results showed that the mixtures containing fibers performed better in the considered tests (toughness index, ductility index, and resilience index). In the impact resistance test, the mixture contained 50% fly ash by weight of the slag with a temperature of

... Show More
View Publication
Crossref (10)
Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Fatigue Behavior Of Chopped Carbon Fiber Reinforced Epoxy Composites
...Show More Authors

Hand-lay up method was used to prepare the samples made of epoxy (EP) as a matrix reinforced with chopped carbon fibers (CCF). The fatigue behavior of epoxy resin /chopped carbon fiber composites was studied with different weight percentage of chopped carbon fibers (2.5%,5%,7.5%,10%,12.5%). The fatigue test was carried out under alternate bending method, which was made by applying sinusoidal wave with constant displacement (15mm), stress ratio R=-1,and loading frequency 10Hz, which is believed to give a negligible temperature rise during the test. The results of the maximum stress, fatigue strength, fatigue limit and fatigue life of the tested composites are calculated from stress(S)-number of cycles(N) (S-N) curves.
It was shown that

... Show More
View Publication Preview PDF