Preferred Language
Articles
/
jbcd-1760
Buccal Cortical Bone Thickness in Iraqi Arab Adults by Cone Beam Computed Tomography for Orthodontic Mini-Implants
...Show More Authors

ABSTRACT Background: Cortical bone thickness is important for the stability of mini implants. Placing mini implants in sites of favorable cortical bone thickness would guarantee better initial stability and long-term success. The aim of this study was to investigate gender, side and jaw differences of the buccal cortical bone thickness as a guide for orthodontic mini screw placement. Materials and Methods: The sample was selected from the patients attending the Specialized Health Center in Al-Sadr City / 3D department. Thirty patients (15 males and 15 females) were selected and cone beam computerized tomographic images were done. Then the buccal cortical bone thickness was measured at thirteen inter radicular sites in the maxilla and mandible from the mesial side of the second molar to the mesial side of the second molar on the other side. The resulting data were statistically analyzed using independent t-test on SPSS program. Results: The buccal cortical bone thickness of the males was more than the females for both jaws. The mandibular buccal cortical bone thickness was thicker than in the maxillary and in the anterior region was thinner than in the posterior region for each jaw. The thickness of the buccal cortical bone was generally greater on the left side

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 07 2018
Journal Name
Asian Journal Of Pharmaceutical And Clinical Research
INVESTIGATING THE EFFECT OF DIFFERENT GRADES AND CONCENTRATIONS OF PH‑SENSITIVE POLYMER ON PREPARATION AND CHARACTERIZATION OF LIDOCAINE HYDROCHLORIDE AS IN SITU GEL BUCCAL SPRAY
...Show More Authors

Objective: The present study was aimed to develop a pH-triggered in situ gel for local release of lidocaine hydrochloride (lidocaine HCL) in the buccal cavity to improve the anesthetic effect of this amino amide drug which has very high water solubility. The formulations were introduced to the oral cavity as a spray to improve compliance and for easier administration.Methods: In this work, two grades of carbopol (934 and 940)-based in situ gel spray were designed. The formulations containing lidocaine HCl 5% were prepared by mixing different concentrations of carbopol with xanthan gum. Eight formulations were investigated and evaluated for gelation capacity, spray angle, volume of solution delivered per each actuation, rheological p

... Show More
View Publication
Scopus (15)
Crossref (7)
Scopus Crossref
Publication Date
Sun Oct 15 2023
Journal Name
Bionatura
Study of the Effect of Diabetes Mellitus I on Bone Mineral Density of Upper and Lower Limbs by Dual-Energy X-Ray Absorptiometry
...Show More Authors

Background: Bone mineral density (BMD) has been assessed using Dual-Energy X-ray absorptiometry (DEXA). This procedure is considered to be of vital importance in assessing the general condition of individuals concerning their skeletal mineralization. BMD is measured according to the results of the DEXA examination of the vertebral column and pelvis. Although diabetes mellitus (D.M.)is known to affect BMD, the information regarding this relationship is not currently particularly clear. Objective: This study concentrates on the point that the assessment of BMD for the vertebral column is insuffi-cient to give a realistic and correct picture of the mineralization of the remaining part of the skeleton. Besides, this study elicited a gen

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Sun Oct 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of mandibular radiomorphometric indices as predictors of osteoporosis in postmenopausal women (Cephalometric reconstructed computed tomographical study)
...Show More Authors

Background: Osteoporosis affects almost all of the bones in the female body; the most important one in the facial bone is mandible. Menopause is defined as an absence of the menses for one year. During this time, estrongen, progesterone and ovarian androgens production are diminished due to adult onset ovarian failure which leads to osteoporosis. This study aimed to evaluate the use of computed tomography mandibular morphometric indices for the assessment of pre and postmenopausal osteoporotic women. Subjects and material: This study conducted on 50 Iraqi females divided into 2 groups 20 -30years old as a control group and over50 years old as a study group attending Al-Karkh hospital, Department of Computed Tomography.(each group25 female).

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
The Effect of Arab Environment on the Artist's Works August Renoir: The Effect of Arab Environment on the Artist's Works August Renoir
...Show More Authors

Abstract:
This study is considerated one of many Studies above the standing of
the Islamic Arab nation which was chosen by God from other nations all over
the world . Some of these nations used to come to the Arab nation to take
whatever useful for them from the beginning of history till now . The
researcher deals in this study with a French artist who is well-know as
August Renoir . He traveled to Algeria and lived there . He was
influenced by the Islamic culture.
The study include. from chapter . chapter one deals with the framework of
programming (out line ) . Chapter two deals with the theoretical framework .
It includes five sections. Deals with the Islamic drawings(Arabesque) . section
three deals w

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 12 2019
Journal Name
International Journal Of Biosciences
Biomechanical and histological assessment of titanium dental implants coated with strontium substituted hydroxyapatite and fluorapatite mixture
...Show More Authors

Dental implants are considered a unique treatment alternative for the replacement of missing dentition. There is a strive for materials which increase bone formation in bone implant interface and improve osseointegration to offer immediate loading directly after placement with decreased time. The aim of the study was to assess the effect of nano strontium substituted hydroxyapatite and nano fluorapatite mixture coating of screw shaped commercially pure titanium at the bone implant interface by torque removal test and histological assessment in rabbit tibia. Commercially pure titanium was used to prepare 80 screws that were divided into machined surfaces (CpTi), coated with (SrHA), coated with (FA) and coated with mixture 50%SrHA + 50%FA (mi

... Show More
Preview PDF
Publication Date
Mon Apr 01 2019
Journal Name
International Journal Of Research - Granthaalayah
CALCULATION OF THE STOPPING POWER OF ALPHA PARTICLES AND ITS RANGE IN BONE TISSU
...Show More Authors

With the advancement of modern radiotherapy technology, radiation dose and dose distribution have significantly improved. as part of Natural development, interest has recently been renewed by treatment, especially in the use of heavy charged particles, because these radiation types serve theoretical advantages in all biological and physical aspects. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with Bone Tissue were calculated by using Zeigler’s formula and SRIM software, also the Range for this particle were calculated by using Mat lab language for (0.01-1000) MeV alpha energy.

Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Evaluation of Serum Osteocalcin and Osteopontin Levels as Bone Biochemical Markers in Postmenopausal Women.
...Show More Authors

Background: Studies discussing the correlation between biochemical markers of bone turnover and the diagnosis of osteoporosis in postmenopausal Iraqi women are rare. This study is devoted to find out the significance of serum osteocalcin (OC) and osteopontin (OPN) levels with the incidence of osteoporosis and its major complication (fracture).Objectives: to investigate the significance of bone turnover biochemical markers; serum osteocalcin and serum osteopontin in evaluating osteoporosis for postmenopausal Iraqi women with and without history of vertebral fracture, as well as to explore the relationship of these markers with bone mineral density (BMD).Methods: Fifty seven postmenopausal women whose ages are fifty years old and over, cat

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Huazhong University Of Science And Technology [medical Sciences]
New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Sun Oct 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Orthodontic Force on Salivary Levels of Alkaline Phosphatase Enzyme
...Show More Authors

Background: Orthodontic tooth movement is characterized by tissue reactions, which consist of an inflammatoryresponse in periodontal ligament and followed by bone remodeling in the periodontium depending on the forces applied. These processes trigger the secretion of various proteins and enzymes into the saliva.The purpose of thi study was to evaluate the activity of alkaline phosphatase (ALP) in saliva during orthodontic tooth movement using different magnitude of continuous orthodontic forces.
Materials and Methods: Thirty orthodontic patients (12 males and 18 females) aged 17-23 years with class II division I malocclusion all requiring bilateral maxillary first premolar extractions were randomly divided into three groups according t

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Upper Removable Orthodontic Appliances on Oral Candidal Mucosal Carriage
...Show More Authors

Background: Treatment of malocclusions using removable orthodontic appliances may prepare new stagnant areas susceptible for colonization and retention of Candida species, therefore; the aim of this study was to investigate the effect of upper removable orthodontic appliances on the mucosal Candidal count in group of apparently healthy orthodontic patients. Materials and Methods: Patients enrolled in this study were children aged 8-12 years having upper removable orthodontic appliances. Candidal counts at six mucosal sites were estimated using Imprint Culture method before, 14 and 28 days during orthodontic therapy. Results: Whole mouth and individual mucosal sites for Candidal counts increase significantly during treatment with upper remov

... Show More
View Publication Preview PDF
Crossref (2)
Crossref