ABSTRACT Background: work-related musculoskeletal disorders represent an important occupational health issues among dentists especially neck and low back complaints. Biomarkers of tissue damage as results of occupational physical demands could be used for detection of work related musculoskeletal disorders. Aim: The aim of this study was to assess work- related musculoskeletal disorders, physical work load index, selected salivary biomarkers (Creatine kinase and C - reactive protein) and to find the relation among them. Subjects and Methods: Study participants are consisted of 112 dentists. They were selected from college of dentistry /Baghdad University, health care center in Bagdad city. They were of both gender and aged between 40-45 years .they should fit the study criteria. Self-administered standardized Nordic questionnaires were used to evaluate musculoskeletal complaints. Physical work load was evaluated by used physical work load index. Stimulated saliva were collected from subsample (87) dentists drawn randomly from the total sample, for whom biochemical analysis (measurement of creatine kinase and C - reactive protein) were done. Results: Results showed that low back and neck complaints is the most complaint experienced by the dentists with percentages of ( 69.6% and 66.1% ), followed by the shoulder complaint (49.1% ) while the hip complaint showed the lowest percentage (13.4%).According to severity scores ,both low back and neck musculoskeletal complaints were of score 3 severity (score 3 constituted the highest percentages in both area (27.7% ,23.2%respectively) as compared to other severity scors.For shoulder complaint it was of score 2 severity (score 2 constituted the highest percentage 23.2% as compared to other severity scores, The musculoskeletal complaints(proximal ,neck, shoulder and low back) had higher mean rank values in the highest quartile of Physical work load index with non – significant differences (P<0.05). Regarding salivary creatine kinase the proximal ,total and low back complaints had higher mean rank values among dentists with highest Creatine kinase quartile , while distal manifestations ,neck and shoulder complaints had higher mean rank value in the average interquartile range of Creatine kinase with non – significant differences( P<0.05). For c- reactive protein almost all the complaints(proximal , total ,neck and shoulder) had higher mean rank values in the first lowest quartile with non – significant differences( P<0.05). Conclusions: Physical work load increase the risk of musculoskeletal disorders occurrence. Salivary creatine kinase could serve as a biomarker that reflects the underlying of musculoskeletal complaints more than C - reactive protein. Further studies that used more objective tools for assessing musculoskeletal disorders is needed.
This investigation reports application of a mesoporous nanomaterial based on dicationic ionic liquid bonded to amorphous silica, namely nano-N,N,N′,N′-tetramethyl-N-(silican-propyl)-N′-sulfo-ethane-1,2-diaminium chloride (nano-[TSPSED][Cl]2), as an extremely effectual and recoverable catalyst for the generation of bis(pyrazolyl)methanes and pyrazolopyranopyrimidines in solvent-free conditions. In both synthetic protocols, the performance of this catalyst was very useful and general and presented attractive features including short reaction times with high yields, reasonable turnover frequency and turnover number values, easy workup, high performance under mild conditions, recoverability and reusability in 5 consecutive runs without lo
... Show MoreThis study sought to investigate the impacts of big data, artificial intelligence (AI), and business intelligence (BI) on Firms' e-learning and business performance at Jordanian telecommunications industry. After the samples were checked, a total of 269 were collected. All of the information gathered throughout the investigation was analyzed using the PLS software. The results show a network of interconnections can improve both e-learning and corporate effectiveness. This research concluded that the integration of big data, AI, and BI has a positive impact on e-learning infrastructure development and organizational efficiency. The findings indicate that big data has a positive and direct impact on business performance, including Big
... Show MoreIn the present study, magnet silica-coated Ag2WO4/Ag2S nanocomposites (FOSOAWAS) were fabricated via a multistep method to address the drawbacks related to single photocatalysts (pure Ag2WO4 and pure Ag2S) and to clarify the significant influence of semiconductor heterojunction on the enhancement of visible-light-driven organic degradation. Different techniques were performed to investigate the elemental composition, morphology, magnetic and photoelectrochemical properties of the fabricated FOSOAWAS photocatalyst. The FOSOAWAS photocatalyst (1 g/L) exhibited excellent photodegradation efficiency (99.5%) against Congo red dye (CR = 20 ppm) after 140 min of visible-light illumination. This result confirmed the ability of the heterojunction be
... Show MoreThree types of metal carboxylates (Ho,Tb and Dy) stearates were LLSed as thennal stabi lizers for PVC. Infrared spectra (1500-1900
|
cm.1
were studied for PVC films stabilized with these metal
carboxylatcs. Two types of oxygen were round -containing products that were formed during the thermal degradation .On the other hand , the presence &nb
... Show MoreTwo series of 1,n-alkylene glycol di [4{N(T-thiazolylazoÂ
nrethinyl)}2-metho y] phenyl ether and I ,n-alkylene glycol di[4{N(r-benzo-thiazolylazomethinyl)}2-methoxy]phenyl ether were synthesize-d via rea tions 2-aminothiazole and 2-aminobenzothiazole with dialdehyde • (which are synthesized from .reaction vanil.lin with
l ,n-dibromo or ehloro. alkane in the basic me'dia ) . &nb
... Show MoreAbstract: Two different shapes of offset optical fiber was studied based on coreless fiber for refractive index (RI)/concentration (con.) measurement, and compare them. These shapes are U and S-shapes, both shapes structures were formed by one segment of coreless fiber (CF) was joined between two single mode (SMF) lead in /lead out with the same displacement (12.268µm) at both sides, the results shows the high sensitive was achieved in a novel S-shape equal 98.768nm/RIU, to our knowledge, no one has ever mentioned or experienced it, it’s the best shape rather than the U-shape which equal 85.628nm/RIU. In this research, it was proved that the offset form has a significant effect on the sensitivity of the sensor. Addi
... Show MoreThe electrical insulation of the manufacture sulfonated phenol-formaldehyde viscous material (product) has been studied with Polyvinyl-acetate (PVA) and toluene diisocyanate (TDI) blend has been prepared by fixing percentage by weight 3:1 and mixed with different percentages by weight of the product sulfonated phenol formaldehyde viscous mass (SPF). The Fourier transform infrared (FTIR) spectroscopy is done on (SPF) resin powder and prepared film of PVA-TDI-SPF viscous mass. The quality factor (Q), dissipation factor (D), parallel resistance (Rp), series resistance (Rs), parallel capacitance (Cp), series capacitance (Cs) and phase shift (?) are measured. The calculated maximum dielectric constant (??) is 3.49x107 at sample (1) wt.1% SPF vis
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show More