Preferred Language
Articles
/
jbcd-1747
Evaluation of Osseointegration of Dental Implants Prepared by Piezosurgery (Clinical Study)
...Show More Authors

ABSTRACT Background: Piezosurgery device is a system developed recently to overcome the limitation of the traditional surgical technique in implant site preparation, which use the principle of ultrasonic microvibrations to create precise & selective cut in bone in harmony with the surrounding tissues. The aim of this study was to evaluate the outcomes of implants inserted by ultrasonic implant site preparation protocol (UISP) using piezosurgery device, regarding the survival rate, stability and other related factors, at 16 weeks postoperative follow up period. Materials and Methods: A total of (24) patients, (6) males and (18) females, aged between (19-51) years old, contributed in this study receiving a total of (42) implants, all of these implants bed were prepared by means of special tips mounted in piezosurgery device. For each patient thorough clinical and radiographical preoperative assessment was applied. Implant stability quotient (ISQ) values were measured at baseline, 8 weeks and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient for 16 weeks postoperatively. Results: (24) patients received (42) implants accomplished the follow-up period, After 16 weeks all implants (42) were osseointegrated and the overall implants survival rate was 100% with no failure and no complication was observed. The mean ISQ value at baseline was (74.32±6.42), the mean ISQ value at 8 weeks was (72.62±9.05) and at 16 weeks the mean ISQ (±SD) value was (76.68±7.35) the changes in the mean stability during the healing period showed significant increase in the implant stability (P≤0.05). At the 16th week the number of implants that achieved ISQ≥70 was 35 (83.3%), and 7 implants attained ISQ> 70 (16.7%). Conclusions: high and significant survival rate, significant secondary stability, early positive shifting of the mean ISQ value, no remarkable complications in implants inserted by ultrasonic implant site preparation indicated that piezosurgery is a reliable alternative and safe method used in dental implant osteotomy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Stomatology
The effectiveness of limited flap design in surgical removal of fully impacted lower third molars: a comparative clinical study
...Show More Authors

Introduction: Surgical removal of impacted lower wisdom teeth is one of the most commonly performed proce- dures in oral and maxillofacial surgery. Objectives: This study aimed to compare the operative and post-operative outcomes of 2 flap designs (limited vs. extended 2-sided flap) in surgical extractions of lower third molars (M3) regarding fully impacted teeth. Material and methods: A prospective, randomized, controlled split-mouth trial was designed, and included 27 patients with bilateral (symmetrically positioned) impacted M3. Limited 2-sided flap was performed on one side (group 1) and extended 2-sided flap on the other side (group 2). The effect of flap design on intra-operative (visibility, accessibility, and duration of surgery) a

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jan 25 2021
Journal Name
Engineering And Technology Journal
Performance evaluation of Photovoltaic Panels by a Proposed Automated System Based on Microcontrollers
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Desalination And Water Treatment
Optimization and kinetic evaluation of reactive yellow dye degradation by solar photocatalytic process
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Journal Of Research In Medical And Dental Science
Processing the Extracted Tooth to Graft the Fresh Socket (Split Mouth Prospective Clinical Study)
...Show More Authors

Background: The dimensional change of alveolar ridge is normal effect of teeth extraction, with unfavourable functional and esthetical outcomes that might jeopardize implant placement. To reduce the biological effects of the dimensional changes of alveolar ridge, various surgical procedures have been recommended, called alveolar ridge preservation. In the previous decade, autogenously teeth have been proposed as bone graft substitution in fresh extraction socket with successful results, yet with various preparation protocols. Aim: Evaluate the formation of new bone derived from the freshly extracted teeth that are grafted immediately in the post extraction sockets, in comparison with sockets without graft filling, by using CBCT and to compa

... Show More
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Canine malposition in Iraqi dental students
...Show More Authors

Background: This study aims to assess the prevalence of malposed canines among students of College of Dentistry/ University of Baghdad and evaluate the relation between canine malposition and occlusal features.

Material and method: The prevalence of buccally malposed canines was estimated by intra-oral visual examination of 250 young adult subjects (106 males and 144 females), their ages were between 19-24 years.

Results: The prevalence of the mandibular malposed canine (12%) was higher than the maxillary buccally malposed canine (10%). Generally, malposed canines were found higher in f

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Pump-Probe Technique to Study of the All-Optical Switching Properties of Copper Phthalocyanine Thin Film prepared via Pulsed laser deposition
...Show More Authors
Abstract<p>Z-scan has been utilized for studying the non-linear properties and optical limiting behaviors of the dye Copper Phthalocyanine thin films. The refractive index is negative, which indicates a self-defocusing behavior and non-linear absorption coefficient (<italic>β</italic>) of CuPc is a positive sign is a result of RSA. The optical switching behaviors of dye have been researched with the use of the method of the pump-probe with 9ns Q-Switched Nd: YAG laser at pump beam equal to 532 nm and a probe beam equal to 630nm Diode laser. The thin films of copper Phthalocyanine also reflect a significant limiting of the optical power of CW laser with an adequate threshold of the opt</p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Study the effect of adding TiO2 nano-powder on some surface properties of TiO2 thin film prepared on stainless steel substrate
...Show More Authors

In this research TiO2 nano-powder was prepared by a spray pyrolysis technique and then adds to the TiO2 powder with particle size (0.523 μm) in ratio (0, 5, 10, 15 at %) atomic percentage, and then deposition of the mixture on the stainless steel 316 L substrate in order to use in medical and industrial applications.
Structure properties including x-ray diffraction (XRD) and scanning electron microscope (SEM0, also some of mechanical properties and the effect of thermal annealing in different temperature have been studied. The results show that the particle size of a prepared nano-powder was 50 up to 75 nm from SEM, and the crystal structure of the powders (original and nano powder) was rutile with tetragonal cell. An improvement in

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of fracture strength of endodontically treated teeth restored by milled zirconia post and core with different post and core systems (An in vitro comparative study)
...Show More Authors

Background: Restoration of root canal treated teeth with a permanent restoration affect in the success of endodontically treated teeth. This in vitro study was performed to evaluate and compare the fracture strength of endodontically treated teeth restored by using custom made zirconium posts and cores, prefabricated carbon fiber, glass fiber and zirconium ceramic posts. Materials and method: Forty intact human mandibular second premolars were collected for this study and were divided into five groups. Each group contains 8 specimens: Group1: Teeth restored with Carbon Fiber Posts; Group2: Teeth restored with Glass Fiber Posts; Group3: Teeth restored with Zirconium Ceramic prefabricated Posts; Group4: Teeth restored with Zirconium Posts

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 23 2025
Journal Name
Yarsi Medical And Dental Science - Yasmine Journal
Oral Biopsy: Evaluating Awareness and Knowledge Among Dental Students at University of Baghdad: Oral Biopsy: Evaluating Awareness and Knowledge Among Dental Students
...Show More Authors

Introduction Oral biopsy is a fundamental diagnostic procedure in dentistry, essential for the early detection of oral cancer and other pathologies. While theoretical knowledge is a core component of dental education, the translation of this knowledge into clinical confidence and practical ability is critical for patient care. Objective: : evaluate the awareness, knowledge, and self-perceived ability to perform oral biopsies Material and Methods: A cross-sectional study was conducted among dental students. Participants (n=110) comprising 14 multiple-choice questions assessing key variables: knowledge of biopsy principles, techniques, lesion identification, specimen preservation, and ability to perform the procedure Results: While theoretica

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Clinical importance of gingival biotype (Review of literature)
...Show More Authors

This review discusses the gingival biotypes, their characteristics, analysis based on the measurement of the dentopapillary complex. Also discuss their response to inflammation, surgery, and ridge healing after tooth extraction, their influence in the behavior of the peri-implant tissue

View Publication Preview PDF