Preferred Language
Articles
/
jbcd-1747
Evaluation of Osseointegration of Dental Implants Prepared by Piezosurgery (Clinical Study)
...Show More Authors

ABSTRACT Background: Piezosurgery device is a system developed recently to overcome the limitation of the traditional surgical technique in implant site preparation, which use the principle of ultrasonic microvibrations to create precise & selective cut in bone in harmony with the surrounding tissues. The aim of this study was to evaluate the outcomes of implants inserted by ultrasonic implant site preparation protocol (UISP) using piezosurgery device, regarding the survival rate, stability and other related factors, at 16 weeks postoperative follow up period. Materials and Methods: A total of (24) patients, (6) males and (18) females, aged between (19-51) years old, contributed in this study receiving a total of (42) implants, all of these implants bed were prepared by means of special tips mounted in piezosurgery device. For each patient thorough clinical and radiographical preoperative assessment was applied. Implant stability quotient (ISQ) values were measured at baseline, 8 weeks and at 16 weeks. Postoperative clinical and radiographic evaluation was applied for each patient for 16 weeks postoperatively. Results: (24) patients received (42) implants accomplished the follow-up period, After 16 weeks all implants (42) were osseointegrated and the overall implants survival rate was 100% with no failure and no complication was observed. The mean ISQ value at baseline was (74.32±6.42), the mean ISQ value at 8 weeks was (72.62±9.05) and at 16 weeks the mean ISQ (±SD) value was (76.68±7.35) the changes in the mean stability during the healing period showed significant increase in the implant stability (P≤0.05). At the 16th week the number of implants that achieved ISQ≥70 was 35 (83.3%), and 7 implants attained ISQ> 70 (16.7%). Conclusions: high and significant survival rate, significant secondary stability, early positive shifting of the mean ISQ value, no remarkable complications in implants inserted by ultrasonic implant site preparation indicated that piezosurgery is a reliable alternative and safe method used in dental implant osteotomy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 12 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Optimized Zaltoprofen Lyophilized Tablets by Zydis Technique
...Show More Authors

“Orodispersible Tablet” a tablet that is to be placed in oral cavity where it disperses rapidly by saliva with no need for water before swallowing. Zaltoprofen (ZLP) is one of NSAIDs which is used in the treatment of rheumatoid arthritis and osteoarthritis as well as to relieve inflammation and pain after surgery, injury and tooth extraction. The present study was aimed to prepare rapidly dissolved lyophilized Zaltoprofen tablet with different pharmaceutical excipients and studying the factors affecting pharmaceutical properties like (solubility, disintegration time DT, dissolution, etc.) of tablets. The lyophilized disintegrating tablets (LDTs) were prepared using Zydis technique by lyophilization an aqueous

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 09 2019
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Silymarin Microcrystals by In- Situ Micronization Technique
...Show More Authors

Silymarin (SM) is a plant extract obtained from Silybum marianum( milk thistle) . It is class II type drug according to  Biopharmaceutics Classification System with low bioavailability due to its low solubility.

Micro/nanonization during crystallization, surface modification and crystal structure modification may improve the dissolution rate of poorly water-soluble drugs.

The aim of this study was to increase the water solubility and dissolution rate of SM by in-situ micronization using solvent change either by stirring or ultrasonic method. Stabilizers like Gelatin, PVP-K30, HPMC15, Pulullan were used to stabilize the prepared ultrafine crystals. Effect of type and concentration of hydrophilic polymer, solv

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Wed Nov 19 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of frictional forces generated by different brackets and orthodontic wires
...Show More Authors

Background: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. The aim of the present in vitro study was to evaluate and compare the static frictional forces produced by two passive self-ligating brackets stainless-steel and hybrid and two conventional brackets stainless-steel and monocrystal ligated with stainless-steel ligature wire at two degrees of torque(zero and twenty) under dry condition. Materials and method: One hundred and sixty brackets were used in this study divided into four groups each group consisted of forty brackets these are: Two self-li

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Evaluation of Patients with Liver Injuries Treated by Perihepatic Gauze Packing
...Show More Authors

Background: The liver is one of the most common organs
injured after blunt abdominal trauma. The control of severe
hemorrhage remains a problem.
Methods: One-hundred thirty-eight patients diagnosed as
liver injury between 09/2003 and 08/2006 had been evaluated
prospectively in Al- Kindy Teaching Hospital.
A distinction was made between hemodynamically stable and
unstable patients. Different modalities of surgical procedures
were done concentrating on perihepatic gauze packing.
Results: (60 out of 138) patients included in the study were
clinically evaluated as hemodynamically stable. The average
abbreviated injury severity score (ISS) was 25. Twenty
patients underwent abdominal surgery. In 12 of them

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Dental Sciences
Evaluation of the efficacy of lycopene gel compared with minocycline hydrochloride microspheres as an adjunct to nonsurgical periodontal treatment: A randomised clinical trial
...Show More Authors

Scopus (12)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Biochemical And Cellular Archives
Evaluation the Effect of Allium Sativum (garlic) oil on The Expression of Maz E and Maz F Genes in Escherichia Coli Clinical Isolates
...Show More Authors

Scopus (4)
Scopus
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Dental Sciences
Evaluation of the efficacy of lycopene gel compared with minocycline hydrochloride microspheres as an adjunct to nonsurgical periodontal treatment: A randomised clinical trial
...Show More Authors

View Publication
Scopus (12)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Al-kindy College Medical Journal
Evaluation of the clinical examination in thediagnosis of acute medial collateral ligament injury of the knee joint in comparism with examination under general anesthesia
...Show More Authors

Background: Tear of MCL of the knee is a frequent problem among knee ligaments injuries.Injuries to the MCL are usually caused by contact on the outside of the knee and are accompanied by sharp pain on the inside of the knee. Contrary to most other knee ligaments the medial collateral ligament (MCL) has an excellent ability to heal, being fairly large and well vascularised structure. The vast majority of isolated medial ligament injuries heal without significant long-term problems

Objectives: is to compare between the early clinical examination, and assessment under general anesthesia (GA), and to find out the best methods to assess the MCL tear especially in suspected cases.

Type

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 07 2020
Journal Name
Journal Of Advanced Research In Fluid Mechanics And Thermal Sciences
Hybrid Bilayer Heterojunction Al/ZnPc/ZnO /ITO Thin Films Solar Cell Prepared by Pulsed Laser Deposition
...Show More Authors

Hybrid bilayer heterojunction Zinc Phthalocyanine (ZnPc) thin-film P-type is considered as a donor active layer as well as the Zinc Oxide (ZnO) thin film n-type is considered as an acceptor with (Electron Transport Layer). In this study, using the technique of Q-switching Nd-YAG Pulsed Laser Deposition (PLD) under vacuum condition 10-3 torr on two ITO (Indium Tin Oxide) and (AL) electrodes and aluminum, is used to construct the hydride bilayer photovoltaic solar cell heterojunction (PVSC). The electrical properties of hybrid heterojunction Al/ZnPc/ZnO/ITO thin film are studied. The results show that the voltage of open circuit (V_oc=0.567V), a short circuit (I_sc=36 ?A), and the fill factor (FF) of 0.443. In addition, the conversion

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Oct 20 2020
Journal Name
Journal Of Research In Medical And Dental Science
The Effect of Chicken Eggshell Extract on Microhardness of Artificially Induced Dental Erosion in Permanent Teeth (In Vitro Study)
...Show More Authors

The Effect of Chicken Eggshell Extract on Microhardness of Artificially Induced Dental Erosion in Permanent Teeth (In Vitro Study), Shatha A Abbas*, Alhan A Qasim

View Publication Preview PDF