ABSTRACT Backgrounds: Maxillary canine impaction is complicated and time consuming to treat, for being highly diverse in inclination and location; it may be a companied by root resorption of the neighboring teeth. CBCT has been used for its' diagnostic reliability in localization of impacted canine and revealing its' serious local complications. Objectives: Localization of maxillary impacted canine using cone beam computed tomography for assessment of angulation, distance from occlusal plane, alveolar width and proximity to adjacent teeth. Subjects and Methods: The study sample was 33 subjects 16 females and 17 males attended to Al-Wasitti general hospital in Baghdad city-Oral and maxillofacial radiology department for CBCT scan investigationfrom November/2015 to April/2016. By using theCS 9000 device, 3D images and coronal, axial and sagittal views obtained to perform the selected measurements. Results: Contact of impacted canine to the nearby teeth had a strong effect on their root resorption. Vertical or horizontal angulation measurement in axial view, was not possible for a number of cases.Comparison of the angulation measurement validity between axial and coronal views, had showed an obvious statistical difference in coronal view for vertical angulation, and in the axial view for horizontal angulation calculation. Correlation of the canine localizations found in the study with the measurements, showed a significant statistical difference with age and vertical angulation (coronal view). Age or gender correlation with the measurements wasnon significant statistically, except for age with vertical angulation (coronal view). Conclusion: utilization of CBCT provides a worthy data about the impacted maxillary canine localization, for more explanation and treatment of these cases surgically and by orthodontics.
Background: Mini implant stability is primarily related to local bone density; no studies have evaluated bone density related to mini implant placement for orthodontic anchorage between different age groups in the maxilla and the mandible. The present research aims to evaluate side, gender, age, and regional differences in bone density of the alveolar bone at various orthodontic implant sites. Materials and method: Fifty three individuals who were divided into two groups according to their age into: group I (ages 16-20 years) and group II (ages 21-29 years) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 102 points (51 in the maxilla
... Show MoreObjectives To tailor composites of polyethylene–hydroxyapatite to function as a new intracanal post for the restoration of endodontically treated teeth (ETT). Methods Silanated hydroxyapatite (HA) and zirconium dioxide (ZrO2) filled low-density polyethylene (LDPE) composites were fabricated by a melt extrusion process and characterised using infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). The flexural strength and modulus were determined in dry state and post ageing in simulated body fluid and fractured surfaces analysed by SEM. The water uptake and radiographic appearance of the experimental composites were also measured and compared with a commercially known endodontic fibre
... Show MoreOptic Disc (OD) localization is a basic step for the screening, identification and appreciation of the risk of diverse ophthalmic pathologies such as glaucoma and diabetic retinopathy.In fact, the fundamental step towards an exact OD segmentation process is the success of OD localization. This paper proposes a fully automatic procedure for OD localization based on two of the OD most relevant features of high-intensity value and vasculature convergence. Merging ofthese two features renders the proposed method capable of localizing the OD within the variously complicated environments such as the faint disc boundary, unbalanced shading, and the existence of retinal pathologies like cotton wall and exudates,which usually share the same
... Show MoreIn a recent study, a special type of plane overpartitions known as k-rowed plane overpartitions has been studied. The function denotes the number of plane overpartitions of n with a number of rows at most k. In this paper, we prove two identities modulo 8 and 16 for the plane overpartitions with at most two rows. We completely specify the modulo 8. Our technique is based on expanding each term of the infinite product of the generating function of the modulus 8 and 16 and in which the proofs of the key results are dominated by an intriguing relationship between the overpartitions and the sum of divisors, which reveals a considerable link among these functions modulo powers of 2.
Methicillin resistant Staphylococcus aureus (MRSA) is one of the principal nosocomial causative agents. This bacterium has the capability to resist wide range of antibiotics and it is responsible for many diseases like skin, nose and wounds infection. In this study, randomly amplified polymorphic DNA (RAPD)-PCR was applied with ten random primers to examine the molecular diversity among methicillin resistant Staphylococcus aureus (MRSA) isolates in the hospitals and to investigate the genetic distance between them. 90 Isolates were collected from clinical specimens from Iraqi hospitals for a total of 90 isolates. Only 10 strains (11.11%) were found to be MRSA. From these 10 primers, only 9 gave clear amplification products. 91 fragment l
... Show More<p>The popularity, great influence and huge importance made wireless indoor localization has a unique touch, as well its wide successful on positioning and tracking systems for both human and assists also contributing to take the lead from outdoor systems in the scope of the recent research works. In this work, we will attempt to provide a survey of the existing indoor positioning solutions and attempt to classify different its techniques and systems. Five typical location predication approaches (triangulation, fingerprinting, proximity, vision analysis and trilateration) are considered here in order to analysis and provide the reader a review of the recent advances in wireless indoor localization techniques and systems to hav
... Show MoreTumours in pets occur naturally and are common in dogs as they are in humans. Tumours of the alimentary system have been reported in animals, although less frequently. Food patterns and specific diet components could have a big role in such tumour occurrence. Therefore, the aim of this study was to investigate the clinical signs and inspect the neoplasm lesions of the gastrointestinal (GI) tract grossly and histopathologically in dogs in Baghdad, Iraq, and to see whether pet diets had any tumourigenic effect. Throughout two years sixteen dogs were referred to Teaching Animal Hospital and private clinics at Baghdad city with masses in (GI) tract. Males and large size breeds were more likely to be affected with GI tumours. Half of the cases a
... Show MoreAim: This study aimed to compare different types of ligation methods to obtain maximum tooth movement with the least undesirable rotation. Methods: Titanium brackets bonded to acrylic canine teeth were ligated to straight stainless steel (SS) archwires using four ligation methods (figure-O and figure-8 elastics, SS ligatures, and Leone Slide ligatures). The teeth with the ligatures in place were stored in a water bath at 37ºC for 1 day, 1 week, 2, 4 or 6 weeks before testing. The teeth were retracted through softened wax along the archwire and the amount of tooth movement and degree of rotation were measured. Results: Slide ligatures showed the highest distance of tooth movement and degree of canine rotation followed by figure-O elastics
... Show MoreThe project has been described the design and construction of a reliable optical testing platform used for evaluate the reflectivity of metal surfaces treated with special paintings required for laser beam attenuation. The platform comprises an Nd-YAG laser system which has been designed and fabricated with specifications to be compatible with their corresponding in laser range finder transmitters used for various applications. The reflectivity of various attenuating paintings, at different detection angles, has been observed. Moreover, the variation of the reflected energy with painting type and metal type to be painted has been studied experimentally. Results illustrated the existence of a definite angle, at which the reflectivity was max
... Show More