Preferred Language
Articles
/
jbcd-169
Postoperative assessment of dental implants by using multi-slice computed tomography
...Show More Authors

Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time period started from December 2012 to April 2013. All the patients who subjected to implant treatment depending on the pre-operative panoramic radiograph were referred Al-Kharkh General hospital, spiral CT scan Department, for postsurgical assessment evaluate the angulation of fixture in relation to the angulation of bone in coronal and sagittal sections by using Multi-Detector Computed Tomography. Results: The present study showed that the angulation of implant affected by age, sector, and tooth position in the same jaw, and not affected by gender. Conclusion: Multi-Slice Computed Tomography provides a great understanding about bone angulation, it necessary as a diagnostic tool for treatment planning pre and post-operatively.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 06 2021
Journal Name
Journal Of Mechanical Engineering Research And Developments
Using Micro-Ceramic as an Abrasive Material to Remove Surface Roughness by Magnetic Abrasive Finishing
...Show More Authors

Due to the rapid advancement of technology and the technology of things, modern industries start to need a highprecision equipment and surface finishing, so many finishing processes began to develop. One of the modern processes is Magnetic Abrasive Finishing (MAF), which is a high-precision process for internal and external finishing under the influence of a magnetic field of abrasive particles. Boron Carbide (B4C) ceramics was tested by mixing it with iron (Fe) and produced abrasive particles to reduce the intensity of scraping on the surface, reduce the economic cost and achieve a high finishing addition to remove the edges at the same time. The material selected for the samples was mild steel (ASTM E415) under (Quantity of Abrasives, Mac

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2014
Journal Name
Paripex-indian Journal Of Research
Inundation Map Development by Using HEC-RAS Hydraulic Simulation Modeling from Roseires to Khartoum Cities
...Show More Authors

Inundation floodingmap aimedto find outearly warningsto avoidenvironmental damageandhumanin terms of theheight ofthe wave ofwater, speed time arrival, effects of inundation sideanddepth of the water/ distanceand reduce the impact of the flood wave after obtaining the process of collapse of the dam in the lower part of the river to the dam area. The study has been using a numerical model one-dimensional depends on the development of equations (Saint-Venant) so that parts of the river, any river channel main banks of the right and left treated as separate parts, that’s the difference in the characteristics of the hydraulic and engineering, along the line of the flow will take into account in each section of the sections and flow in the riv

... Show More
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride
...Show More Authors

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Chemical Engineering And Processing - Process Intensification
Cobalt Removal from Simulated Wastewaters Using a Novel Flow-by Fixed Bed Bio-electrochemical Reactor
...Show More Authors

View Publication
Scopus (32)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Determination the concentration for uranium in phosphrous fertilizers by using nuclear track detector CR-39
...Show More Authors

The aim of this research was to study the concentrations of Uranium in the phosphorus fertilizers using Nuclear track detector (CR-39). Our present investigation is based on the study of 10 types samples for different kinds of phosphorus fertilizers which were available in the local market Some of them were Iraqi made and the others from different countries like, (Iran, Italy, Holland, Lebanon and Jordan) .. The result obtained shows that the Uranium concentration in phosphorus fertilizers samples varies from (3.59ppm) to(2.59ppm). Based on the radioactive concentration of Uranium in the samples all the results obtained between(3.59ppm) in the Iraqi super phosphate to (2.59ppm) in the mixture Iraqi phosphate fertilizer are withi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Civil And Environmental Engineering
Developing A Mathematical Model for Planning Repetitive Construction Projects By Using Support Vector Machine Technique
...Show More Authors
Abstract<p>Each project management system aims to complete the project within its identified objectives: budget, time, and quality. It is achieving the project within the defined deadline that required careful scheduling, that be attained early. Due to the nature of unique repetitive construction projects, time contingency and project uncertainty are necessary for accurate scheduling. It should be integrated and flexible to accommodate the changes without adversely affecting the construction project’s total completion time. Repetitive planning and scheduling methods are more effective and essential. However, they need continuous development because of the evolution of execution methods, essent</p> ... Show More
View Publication
Crossref (3)
Clarivate Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of the Risk Factors of Coronary Artery Diseases in Al-Nasiriyah City
...Show More Authors

Objective: to assess the risk factors of coronary artery disease patients.
Methodology: A non-probability (purposive) sample of (100) patients. The study population consisted of
a sample of adults from both genders whose ages were 30 years and more, and was newly diagnosed as
having CAD by coronary angiography in the cardiac catheterization unit of An Nasiriyah heart center.
Results: The result of the study showed that the most common modifiable risk factors were low HDL-C
levels (58%), smoking (53%), hypertension (46%), diabetes mellitus (34%), obesity (30%), high
triglycerides (19%), hypercholesterolemia (17%), and high LDLC (14%). All these factors were positively
and significantly associated with the development

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Oral And Maxillofacial Surgery, Medicine, And Pathology
Assessment of the extracapsular dissection of the benign parotid tumors, extending the literature
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Thu Jan 02 2020
Journal Name
Journal Of Research In Medical And Dental Science
Assessment of Surface Roughness and Surface Wettability of Laser Structuring Commercial Pure Titanium
...Show More Authors

Aim: To evaluate the commercial pure titanium disks that structuring by laser in two design (dot and groove) each one with three different laser scan (5, 15 and 25) and comparing with titanium surface that not subjected to any surface structuring (control) through measuring the wettability test and surface roughness test. Materials and methods: Structuring on the surface of the commercial pure titanium (CP Ti) disks was performed via using fiber laser CNC machine in two design (dot and groove) in three different laser scans (5, 15 and 25), then the structuring disks analyzed with the control group by atomic force microscope and water contact angle test. Results: The results of this study showed that the surface roughness and the wettability

... Show More
Preview PDF