Background: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different brand configurations: closed loop and open (short filament) chains under effect of time at (zero time, 24hr., 7, 14 , 21 and 28 days) in artificial saliva. Results: Statistical analysis showed that there was a highly significant difference in the mean percentage force decay for the three different mechanisms (P? 0.001).For all the three types, the 6-3 mechanism had the smallest mean percentage force decay. There was a highly significant difference in the mean percentage force decay for the different types (P? 0.001). For all three mechanisms, extreme silver elastomeric chains had the smallest percentage force decay while maximum silver elastomeric chains had the highest percentage force decay. Conclusion: This study illustrated that for all the three types of elastomeric chains, the (6-3) mechanism had the smallest mean percentage force decay. This finding suggests that it may be most efficient to retract a canine utilizing elastomeric chain directly from the molar hook to the canine bracket. The chain loop mechanism may not be indicated for space closure in vivo due to the excessive physiological force values involved with this mechanism.
Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in
... Show MoreBackground Many countries recommend the use of long-acting reversible contraceptive intrauterine device immediately after cesarean delivery. The cesarean delivery rate in Iraqi public hospitals is 32.2% and may reach 85.8% in private hospitals. Immediate post-partum intrauterine device insertion at cesarean is rarely done in Iraq. Objectives To assess the safety and practicality of immediate post-partum intrauterine device insertion during cesarean delivery for family planning and pregnancy spacing in Iraqi women. Subjects and Methods A single arm clinical trial included 150 eligible women who attended Al-Elwiyah Maternity Teaching Hospital or Al Hayat Rahibat Hospital for term delivery. A copper intrauterine device was placed in the ute
... Show MoreBackground: The fracture of instruments within root canal during endodontic treatment is a common incidence, fracture because of fatigue through flexure occurs due to metal fatigue, this study aimed to assess the effect of curvature angle and rotational speed on the cyclic fatigue of different type of Endodontic NiTi Rotary Instruments and compare among them. Materials and method: Three types of rotary instruments with tip size 0.25: ProTaPer F2 (Densply, Malifier) Revo-S SU( 0.06 taper, MicroMega) and RaCe system (0.06 taper, FKG, Dentaire), Forty file of each instrument were used within two canals with angle of curvature (40 &60 )at two speed (250&400)RPM, twelve group were formed for all instruments(total number=120),ten file fo
... Show Morethe physical paraneters of oxadizole derivaties as donor molecules have been measured the charge transfer and methanol as solvent have been estimated from the electonic spectra
Solar module operating temperature is the second major factor affects the performance of solar photovoltaic panels after the amount of solar radiation. This paper presents a performance comparison of mono-crystalline Silicon (mc-Si), poly-crystalline Silicon (pc-Si), amorphous Silicon (a-Si) and Cupper Indium Gallium di-selenide (CIGS) photovoltaic technologies under Climate Conditions of Baghdad city. Temperature influence on the solar modules electric output parameters was investigated experimentally and their temperature coefficients was calculated. These temperature coefficients are important for all systems design and sizing. The experimental results revealed that the pc-Si module showed a decrease in open circuit v
... Show MoreThe possible effects of COVID-19 vaccines on reproductive health and male fertility in particular have been discussed intensely by the scientific community and the public since their introduction during the pandemic. On news outlets and social media platforms, many claims have been raised regarding the deleterious effects of COVID-19 vaccines on sperm quality without scientific evidence. In response to this emerging conflict, we designed this study to evaluate and assess the effect of the Pfizer-BioNTech mRNA COVID-19 vaccine on male fertility represented by the semen analysis parameters.
Discrete Raman amplifier have many attractive aspects over rare-earth doped fiber amplifier such as (EDFA) including arbitrary gain band, better adjustability of gain shape, and better linearity. This paper shows that discrete Raman amplifier has higher gain in bidirectional pumping than counter pumping. The gain increases with increasing fiber length, and the noise figure remain at the same value for short fiber length.