Background: Periodontal diseases are bacterial infections of the gingiva, bone and attachment fibers that support the teeth and hold them in the jaw. α-amylase is an enzyme, produced mainly by parotid gland and it seems to play a role in maintaining mucosal immunity. Aims of the study: Determine the salivary levels of α-Amylase and flow rate and their correlations with clinical periodontal parameters(Plaque Index , Gingival Index , Bleeding on Probing , Probing Pocket Depth , and Clinical Attachment Level ) and the correlation between α-Amylase with flow rate of study groups that consist of ( patients had gingivitis and patients had chronic periodontitis with different severities(mild ,moderate ,severe) and control group . Materials and Methods: Salivary α-Amylase and flow rate levels with clinical periodontal parameters(Plaque Index , Gingival Index , Bleeding on Probing , Probing Pocket Depth , and Clinical Attachment Level ) were measured from 75 males , age ranged (30-45) years old, that divided into study groups(group of 45chronic periodontitis patients with different severities which sub-grouped into (Mild=15, Moderate=15 and Severe=15), group of 15 patients with gingivitis) and control group comprised 15 subjects had clinically healthy periodontium. Results: The levels of salivary α-amylase in patients had chronic periodontitis were the highest followed by patients had gingivitis .Highly significant differences were demonstrated between each pairs of chronic periodontitis subgroups hence, the highest level at severe chronic periodontitis subgroup patients. Flow rate decreased in gingivitis group and chronic periodontitis with its different severities. Highly significant strong positive correlations were found between α-amylase with clinical periodontal parameters at all groups and subgroups. Conclusions: The findings of the present study suggest that salivary α-Amylase can help to monitor the progression of the periodontal disease.
In this study, light elements for 13C , 16O for (α,n) and (n,α) reactions as well as α-particle energy from 2.7 MeV to 3.08 MeV are used as far as the data of reaction cross sections are available. The more recent cross sections data of (α,n) and (n,α) reactions are reproduced in fine steps 0.02 MeV for 16O (n,α) 13C in the specified energy range, as well as cross section (α,n) values were derived from the published data of (n,α) as a function of α-energy in the same fine energy steps by using the principle inverse reactions. This calculation involves only the ground state of 13C , 16O in the reactions 13C (α,n) 16O and 16O (n,α) 13C.
To determine the seroprevalence of hepatitis B markers in chronic hepatitis B patients, 75 patients with chronic hepatitis B virus of ages (8-70) years have been investigated and compared with 50 apparently healthy individuals. All the studied groups were carried out to measure (HBsAg), (HBsAb), (HBeAg), (HBeAb), and (Total HBcAb) by Enzyme linked immunosorbent assay (ELISA) technique. The percentage distribution of HBsAg was (86.67%) and HBsAb was (1.33%) in sera of CHB patients and there were a highly significant differences (P<0.01) when compared between studied groups, while, the percentage distribution of HBeAg was (22.67%) in sera of CHB patients and the significant represent the difference in distribution of HBeAg as infection but no
... Show MoreAfter about twelve months or maybe more, some people can’t achieve pregnancy. This might be a sign of infertility as a reproductive system disease. The following study was carried out to investigate the DAZ 1 gene methylation level and its association with azoospermia in Iraqi patients. One hundred and fifty human blood samples were collected from from different regions in Baghdad governorate, including (private medicals Labs and the high institute for infertility diagnosis assisted reproductive techniques and Kamal Al- Samara'ay IVF Hospital) from both fertile and infertile men. The control group consists of 50 samples ranging from 22 to 51 years old, while the patient (infertile group) consists of 100 samples ranging between 25 and 51 y
... Show MoreIn this research, we discussed and analyzed the relationship between oil prices and the U.S. dollar exchange rate in Iraq. The study adopted the descriptive analysis and econometrics analysis. The descriptive analysis refers to the rise (fall) in crude oil price lead to appreciate (depreciate) in the Iraqi dinar exchange rate, though the channel of the international reserves. The econometrics analysis is based on monthly data covered the period (December/2002 – December/2011), the unit root test, co-integration test, vector error correction model, and Granger causality test have been adopted in this research to check the existence and direction of this relationship. The results refer to the lon
... Show MoreThe new Schiff base (L) “4‐[(2,4‐dimethoxy‐benzylidene)‐amino]‐1,5‐dimethyl‐2‐phenyl‐1,2‐dihydro‐pyrazol‐3‐one” was synthesized from 2,4‐dimethoxy‐benzaldehyde and 4‐amino‐1,5‐dimethyl‐2‐phenyl‐1,2‐dihydropyrazol‐3‐one, and the geometry of Schiff base was characterized and determined by proton nuclear magnetic resonance (1H‐NMR), mass, Fourier transform infrared (FT‐IR), and ultraviolet‐visible (UV‐vis) spectroscopy. Schiff complexes of Ni(II), Pd(II), Pt(IV), Zn(II), Cd(II), and Mg(II) have been prepared by reaction of ion metals with as‐prepared Schiff base. The results showed that synthesized complexes offered 1:2 m
Atenolol was used with ammonium molybdate to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and ammonium molybdate in an aqueous medium to obtain a dark brown precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.1-3.5 mmol/L for cell A and 0.3-3.5 mmol/L for cell B, and LOD 133.1680 ng/100 µL and 532.6720 ng/100 µL for cell A and cell B respectively with correlation coefficient (r) 0.9910 for cell A and 0.9901 for cell B, RSD% was lower than 1%, (n=8) for the determination of ate
... Show MoreThe Boltzmann transport equation is solved by using two- terms approximation for pure gases . This method of solution is used to calculate the electron energy distribution function and electric transport parameters were evaluated in the range of E/N varying from . 172152110./510.VcmENVcm
From the results we can conclude that the electron energy distribution function of CF4 gas is nearly Maxwellian at (1,2)Td, and when E/N increase the distribution function is non Maxwellian. Behavior of electrons transport parameters is nearly from the experimental results in references. The drift velocity of electron in carbon tetraflouride is large compared with other gases
The research talks about the concept of investment allocations, showing its linguistic and idiomatic meaning, as well as the objectives for which the investment allocations are based, as well as the benefits of these allocations since it shows types of investment contracts, including: current and fixed assets and commitment allocations.
The research has been concluded with several results, including the protection of the banks and the investor. The contracting parties focus on specific dates that both parties are obliged to abide by, the research also shows the jurisprudence provisions for investment allocations, each ruling according to the specific branch.
... Show MoreIn this research the effect of cooling rate and mold type on mechanical properties of the eutectic
and hypoeutectic (Al-Si) alloys has been studied. The alloys used in this research work were (Al- 12.6%Si
alloy) and (Al- 7%Si alloy).The two alloys have been melted and poured in two types of molds with
different cooling rates. One of them was a sand mold and the other was metal mold. Mechanical tests
(hardness, tensile test and impact test) were carried out on the specimens. Also the metallographic
examination was performed.
It has been found that the values of hardness for the alloys(Al-12.6%Si and Al-7%Si) which poured in
metal mold is greater than the values of hardness for the same alloy when it poured in a heated