In Vitro Comparative Assessment of Composite Nanoleakage Using Various Dentine Surface Treatments
...Show More Authors

Background: The treatment of dental tissues proceeding to adhesive procedures is a crucial step in the bonding protocol and decides the clinical success ofrestorations. This study was conducted in vitro, with the aim of evaluating thenanoleakage on the interface between the adhesive system and the dentine treated by five surface modalities using scanning electron microscopy and energydispersiveX-ray spectrometry. Materials and methods: Twenty five extracted premolars teeth were selected in the study. Standardized class V cavities were prepared on the buccal and lingual surfaces then the teeth divided into five main groups of (5 teeth in each group n=10) according to the type of dentine surface treatment that was used: Group (A): dentine was conditioning with Er, Cr: YSGG laser. Group (B): dentine was conditioning with (Er, Cr: YSGG laser + acid). Group (C): dentine was conditioning with (acid + Er, Cr: YSGG laser). Group (D): dentine was conditioning with acid etch. Group (E): dentine was conditioning with acid + 10% sodium hypochlorite. For All the teeth SBMP adhesive were used and restored with Z250 composite restoration then all specimens were subjected to thermocycling 500 cycles, at 5° to 55 °C. The teeth were soaked in silver nitrate suspension. Then the teeth sectioned bucco-lingually across the centre of the restorations. The specimens were characterized using scanning electron microscopy and the amount of nanoleakage was measured by EDX spectro-analysis to identify the existence of metallic silver particles. Results: Data were analysed statistically by one way ANOVA test and (LSD) Tests. The results showed that there were statistically highly significant differences among all groups of the present study.The resultshowed that the acid and laser (group III) exhibited the lowest mean value of nanoleakage at around (6.14 %), whereas the highest mean value of nanoleakage (12.83 %) was determined by the only acid (group IV). Conclusions: Treating the acid etched dentine with Er: Cr: YSGG laser showed promising results as it exhibits lowest amount of nanoleakage of the adhesive bonding system.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Fracture resistance of weakened premolars restored with sonically-activated composite, bulk-filled and incrementally-filled composites(A comparative in vitro study)
...Show More Authors

Background: This study was conducted to assess the effect of sonic activation and bulk placement of resin composite in comparison to horizontal incremental placement on the fracture resistance of weakened premolar teeth. Materials and method: Sixty sound human single-rooted maxillary premolars extracted for orthodontic purposes were used in this study. Teeth were divided into six groups of ten teeth each: Group 1 (sound unprepared teeth as a control group), Group 2 (teeth prepared with MOD cavity and left unrestored), Group 3 (restored with SonicFill™ composite), Group 4 (restored with Quixfil™ composite), Group 5 (restored with Tertic EvoCeram® Bulk Fill composite) and Group 6 (restored with Universal Tetric EvoCeram® co

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Propagation Mechanisms for Surface Initiated Cracking in Composite Pavements
...Show More Authors

The primary objective of this study was to identify the mechanisms for the development and propagation of longitudinal cracks that initiate at the surface of composite pavement. In this study the finite element program ANSYS version (5.4) was used and the model worked out using this program has the ability to analyze a composite pavement structure of different layer properties. Also, the aim of this study was modeling and analyzing of the composite pavement structure with the physical presence of crack induced in concrete underlying layer. The results obtained indicates that increasing the thickness of the asphalt layer tends to decrease the stress intensity factor, which may be attributed to the rapidly decrease of horizontal tensile st

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Gingival Marginal Leakage of Different Tooth Colored Materials Combination as an Intermediate Layer in Class II Composite Restoration (A Comparative In Vitro Study)
...Show More Authors

Background: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon May 27 2019
Journal Name
Al-khwarizmi Engineering Journal
Investigation the Optimization of Machining Parameters to Surface Roughness in Free Form Surface of Composite Material
...Show More Authors

The aim of this research is to investigation the optimization of the machining parameters (spindle speed, feed rate, depth of cut, diameter of cutter and number of flutes of cutter) of surface roughness for free-form surface of composite material (Aluminum 6061 reinforced boron carbide) by using HSS uncoated flat end mill cutters which are rare use of the free-form surface. Side milling (profile) is the method used in this study by CNC vertical milling machine. The purpose of using ANFIS to obtain the better prediction of surface roughness values and decreased of the error prediction value and get optimum machining parameters by using Taguchi method for the best surface roughness at spindle speed 4500 r.p.m, 920mm/rev feed rate, 0.6mm de

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Baghdad Science Journal
Assessment of surface water quality using statistical analysis methods: Orontes River (Case study)
...Show More Authors

The study investigates the water quality of the Orontes River, which is considered one of the important water recourses in Syria, as it is used for drinking, irrigation, swimming and industrial needs. A database of 660 measurements for 13 parameters concentrations used, were taken from 11 monitoring points distributed along the Orontes River for a period of five years from 2015-2019, and to study the correlation between parameters and their impact on water quality, statistical analysis was applied using (SPSS) program. Cluster analysis was applied in order to classify the pollution areas along the river, and two groups were given: (low pollution - high pollution), where the areas were classified according to the sources of pollution to w

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Investigation and Comparative Study Among Various Methods of Contraception Used in Erbil City
...Show More Authors

The objective of this study was to investigate and compare among five different methods of contraception including combined oral contraceptive pills (COC), Depot medroxyprogesterone acetate (DMPA), copper Intrauterine contraceptive device (IUCD), vaginal spermicides and male condom used in Hawler City through estimate of their effect, relative failure rate, percentage of use, adherence and compliance and adverse effects of each contraceptive method. In order to reach to these aims, a retrospective study was conducted in Hawler City in Azadi Health Care Center over a period of 6 months from 22th November, 2010 to 15th May, 2011 during which data collection and subjects follow up for 3 months had been achieved. A conv

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Microleakage of Pit and Fissure Sealants after Using Different Occlusal Surface Preparation Techniques: An In Vitro Study
...Show More Authors

Background: The marginal seal is essential for sealant success because penetration of bacteria under the sealant might allow caries onset or progression. The aim of the present study was to estimate and compare the microleakage of pit and fissure sealant after various methods of occlusal surface preparation. Materials and methods: Thirty non-carious premolars extracted for orthodontic reasons were equally divided into three groups. In group one, occlusal fissures were opened with round carbide bur, in group two, occlusal surfaces of the teeth were cleaned with a dry pointed bristle brush and samples of group three were cleaned with a slurry of fine flour of pumice in water using rubber cup. Then fissures of all teeth were etched using 35% p

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Radiopacity of modified microhybrid composite resin:(An in vitro study)
...Show More Authors

Background: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of certain chemical surface treatments on repair bond strength of some denture base materials
...Show More Authors

Background: Fracture of different types of acrylic denture base is a common problem associated with dental prosthesis. Studies suggested that the repair strength may be improved by several means including surface treatment with chemical agents. The aim of the study was to evaluate the effect of surface treatment with acrybond-bonding agent and monomer on fractured denture base in respect to transverse, tensile and shear bond strength and evaluation of the mode of failure by light microscope. Materials and methods: Two hundred seventy specimens were prepared and divided into 3 groups according to the material used (regular conventional, rapid simplified and high impact) heat cure acrylic. The specimen in each groups were prepared specificall

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment of the Effect of Gutta-Fusion Obturation on the Push Out Bond Strength of Three Types of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in

... Show More
View Publication Preview PDF
Crossref (2)