Background: With the increase in composite material use in posterior teeth, the concerns about the polymerization shrinkage has increased with the concerns about the formation of marginal gaps in the oral cavity environment. New generation of adhesives called universal adhesive have been introduced to the market in order to reduce the technique sensitive bonding procedures to give the advantage of using the bonding system in any etching protocol without compromising the bonding strength. The aim of the study was to study marginal adaptation of two universal adhesives (Single bond™ Universal and Prime and Bond elect) using 3 etching techniques under thermal cycling aging. Materials and Methods: Forty-eight sound maxillary first premolar teeth were included in the study. Teeth were divided into two groups according to the universal adhesive used then each group was subdivided into 3 subgroups according to the etching protocol used. Standardized class I cavities were prepared in the teeth followed by the restoration of teeth using Filtek™ Bulk Fill Posterior Restorative composite material. After finishing and polishing, teeth were subjected to 500 thermal cycles in 55º-5ºC bath with dwell time of 30 seconds. Teeth then were examined using SEM to measure the marginal gap at 12 points. Data obtained were analyzed using one-way ANOVA and LSD test for each group and with student t-test to compare the two adhesives. Results: The result of this study the showed that etch and rinse technique showed significantly the least marginal gap width for both adhesive types. The selective etch technique showed lower gaps compared to the self-etch technique with no significant difference. The result showed that single bond universal showed significantly the least marginal gap for the all etching techniques compared to Prime and bond elect. Conclusion: The etch and rinse technique remains the most suitable technique for adhesive restoration. The type of adhesive plays an important role in adhesion.
The present study aimed to identify teaching problems which facing the teachers for first three grades classes, and if these problems different according to some variables teacher qualification, experience period, class grade). The study sample consist of (137 )
female teachers who teach the first three grades in Braimy city in Oman, teachers spread in five government schools. Both researchers developed questionnaire to measure problems faced by the mentioned teachers, consist of 50 questions distributed into 4 dimensions (teacher, students, the curriculum, the evaluations), Also researchers checked questionnaire validity and stability. The results indicate to: The most common probl
... Show MoreBackground: Porcelain veneers are under a great deal of stress which may lead to clinical failure as fracture or dettachment. This study examined whether different finishing lines and lingual shoulder preparations in the incisal area of the maxillary central incisor affect the bond of the porcelain veneers. Materials and methods: A two- dimensional finite element model was made. Location and magnitude of maximum Von Mises stresses were calculated in porcelain veneer. Six types of preparations were drawn as:incisal overlap of 0.5mm, 1mm and 1.5mm depth and lingual shoulder, and incisal overlap of 0.5mm, 1mm and 1.5mm depth without shoulder preparation. Results: Stress formation is maximum in the incisal edge region. All the lingual shoulder
... Show MoreThis study evaluates the performance of magnetic abrasive finishing (MAF) of aluminum alloy in terms of achieving materials removal (MR). A vertical milling machine is used to perform the finishing process using a developed MAF unit that consists of an inductor made out of a 150 mm long and 20 mm diameter iron core wound with 1500 turns and 0.5 mm copper wire. The commutator and magnetic pole are attached at the top and bottom of the inductor, respectively. The required current is supplied using a DC power supply. The South Pole workpiece is a 100×50×3 mm3 plate of AA 1100 aluminum alloy, whereas the magnetic pole represented the North Pole. Pole rotational speed, applied current, and abrasive finishing time was selected as
... Show MoreThe present work involved a study the effect of cobalt(II) complex with formula [CoL(H2O)NO3] .4ETOH where L=Nitro [5-(P-nitro phenyl) -4-phenyl-1,2,4 traizole-3-dithiocarbamato hydrazide] aqua. (4) Ethanol and anti-cancer drug - cyclophosphamide on specific activity of two liver enzymes (GPT,ALP) by utilizing an in vivo system in female mice. On the enzymatic level an inhibition in the activity of GPT was noticed in different body organs such as liver, kidney and lung. The inhibition was noticed in both test and cyclophosphamide drug (cp). Mice were treated with three doses of cyclophosphamide (90,180, 250) ?g/ mouse for three days. The same doses were used for the cobalt (II) complex. The liver shows the highest rate of(GPT) inhibition co
... Show MoreAbstract :
The research aims to Estimate the Strength of Strategic Innovation application in terms of application strength , and on the overall level in number of Iraqi Industrial business organizations . After wards determine whether their is differerences among those organizations in application process for the dimensions , and for the overall process .
The Research revealed number of conclusions including that the process of strategic innovation is applied in a good Level , and demonstrates the desier of the industrial companies Leaders to Launch beyond the familiar products , and to provide new products that
... Show MoreThe Atoms in Molecules (AIM) analysis for triosmium cluster, which contains trihydridede, carbon, carbonyl and 2-methylbenzothiazolide ligands, [Os3(µ-H)3(µ3-ɳ2-CC7H3(2-CH3)NS)(CO)8] is reported. Bonding features in this cluster has been analyzed based on QTAIM ("Quantum Theory of Atoms in Molecules") in this work. The topological indices derived from electron density of relevant interactions in triosmium compound have been studied. The major interesting point of the AIM analyses is that the core of part (Os3H3) reveals the absence of any critical points and bond paths connecting any pairs of O
... Show MoreBackground: Titanium implant is widely used in dentistry because of its extraordinary biocompatibility and mechanical properties. To increase bone–implant connection and provide early loading after placement, implant is stored in different storage medium and treated with UV light. Both of them are applicable methods to increase the bioactivity of titanium and overcome the biological aging. This study was designed to assess the effect of vacuum storage method and air storage with and without UV light treated of Cp Ti implant mechanically and histologically. Materials and methods: Titanium screws were acid etched and prepared in four different modes using different storage methods (air or vacuum and, with or without UV treatment. The implan
... Show MoreThe improvement of the mechanical soil characteristics of jet grouting technique is very attractive. The jet grouted soil cement columns in soft is a complicated issue because it depends on a number of factors such as, soil nature, mixture, influence among soil and grouting materials, jetting force of nozzle, jet grouting and water flow rate, rotation and lifting speed. This paper discusses the estimation of shear strength parameters of soil-cement column (soilcrete) in soft clayey soil based on the relationships between the unconfined compressive and split tensile strength for the soilcrete and the effect of the jet grouting and water pressure in the values of cohesion and internal f
Introduction: Surgical removal of impacted lower wisdom teeth is one of the most commonly performed proce- dures in oral and maxillofacial surgery. Objectives: This study aimed to compare the operative and post-operative outcomes of 2 flap designs (limited vs. extended 2-sided flap) in surgical extractions of lower third molars (M3) regarding fully impacted teeth. Material and methods: A prospective, randomized, controlled split-mouth trial was designed, and included 27 patients with bilateral (symmetrically positioned) impacted M3. Limited 2-sided flap was performed on one side (group 1) and extended 2-sided flap on the other side (group 2). The effect of flap design on intra-operative (visibility, accessibility, and duration of surgery) a
... Show More