Background: With the increase in composite material use in posterior teeth, the concerns about the polymerization shrinkage has increased with the concerns about the formation of marginal gaps in the oral cavity environment. New generation of adhesives called universal adhesive have been introduced to the market in order to reduce the technique sensitive bonding procedures to give the advantage of using the bonding system in any etching protocol without compromising the bonding strength. The aim of the study was to study marginal adaptation of two universal adhesives (Single bond™ Universal and Prime and Bond elect) using 3 etching techniques under thermal cycling aging. Materials and Methods: Forty-eight sound maxillary first premolar teeth were included in the study. Teeth were divided into two groups according to the universal adhesive used then each group was subdivided into 3 subgroups according to the etching protocol used. Standardized class I cavities were prepared in the teeth followed by the restoration of teeth using Filtek™ Bulk Fill Posterior Restorative composite material. After finishing and polishing, teeth were subjected to 500 thermal cycles in 55º-5ºC bath with dwell time of 30 seconds. Teeth then were examined using SEM to measure the marginal gap at 12 points. Data obtained were analyzed using one-way ANOVA and LSD test for each group and with student t-test to compare the two adhesives. Results: The result of this study the showed that etch and rinse technique showed significantly the least marginal gap width for both adhesive types. The selective etch technique showed lower gaps compared to the self-etch technique with no significant difference. The result showed that single bond universal showed significantly the least marginal gap for the all etching techniques compared to Prime and bond elect. Conclusion: The etch and rinse technique remains the most suitable technique for adhesive restoration. The type of adhesive plays an important role in adhesion.
Optoelectronic devices, widely used in high energy and nuclear physics applications, suffer severe radiation damage that leads to degradations in its efficiency. In this paper, the influence of gamma radiation (137Ce source) and beta radiation (90Sr source) on the photoelectric parameters of the Si solar cell, based on the I–V characterization at different irradiation exposer, has been studied. The penetrating radiation produces defects in the base material, may be activated during its lifetime, becoming traps for electron–hole pairs produced optically and, this will, decrease the efficiency of the solar cell. The main objective of the paper is to study and measure changes in the I–V characteristics of solar cells, such as efficienc
... Show MoreBackground: This study aimed to determine whether there is a relationship among the bite force with facial dimensions and dental arches in a sample of Iraqi adults with Class I skeletal and dental relations. Materials and methods: Forty dental students (20 males and 20 females) were selected under certain criteria. For those individuals, dental impressions, frontal facial photographs and maximum bite force at molar and incisor regions were taken. The dental arches widths and facial dimensions were measured using the AutoCAD program 2007, while the bite force was determined using special device. Descriptive statistics for the measured variables were performed and gender difference was determined using independent sample t-test, while the rel
... Show MoreIraqi oil crudes have some of the physical and chemical characteristics that distinguish it from other types of oil crudes in the world. Some of these features such us molecular composition, rheological, viscosity and emulsions are studied carefully by researchers. In this work, a comparative study of the linear and the non-linear optical properties for typical heavy and light crude oils of Iraqi origin was studied utilizing Z-scan technique. The He -Ne laser of wavelength 632.8 nm had been used for this purpose. These samples were collected from Basra and Kut oil fields. The values of the non-linear refractive index (n2), non-linear absorption coefficient (β), and third-order electrical susceptibility (χ3) were e
... Show MoreBackground: Elastomeric chains are one of the most commonly used force delivery systems. They have the ability to exert a continuous force, convenience of use, compatibility to oral environment and cost effectiveness but one of the inherited disadvantages is force degradation. Materials and methods: This in vitro study was designed to evaluate the effect of alcohol presence in mouthwashes on force decay of different configurations of clear elastomeric chains from (Ortho Technology company) which are: closed , short and long under the effect of time at (Initial, 1, 2, 3 and 4 weeks) intervals with exposure to different chemical solutions. A total (540) modules of elastomeric chains of three different types (long, short and closed) trans
... Show MoreBackground:The demand for esthetic orthodontic appliances is increasing so that the esthetic orthodontic archwires were introduced. This in vitro study was designed to evaluate the surface roughness offiber-reinforced polymer composite (FRPC) archwires compared to coated nickel-titanium (NiTi) archwires immersed in artificial saliva. Materials and Methods:Three types of esthetic orthodontic archwires were used: FRPC (Dentaurum), Teflon coated NiTi (Dentaurum) and epoxy coated NiTi (Orthotechnology). They were round (0.018 inch) in cross section and cut into pieces of 15 mm in length.Forty pieces from each type were divided into four groups; one group was left at a dry condition and the other three groups were immersed in artificial saliva (
... Show MoreBackground: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l
... Show MoreThe objective of this research is to identify the effect of Using Fryer strategy on achievement and systemic thinking in the subject of chemistry of second class intermediate school students. The sample of research consisted of 59 students in one intermediate school in Baghdad/Iraq, split into two groups; experimental and control. The scientific material of the study is related to Chapters II and III of the Science Book for the second Intermediate School for the Year (2019-2020). The scientific test is composed of 25 test items whilst the second instrument for research related to systematic thinking test consisted of 12 items. The results of the research showed that the use of Fryer's chemistry-teaching strategy has increased achieve
... Show MoreThe objective of this research is to identify the effect of Using Fryer strategy on achievement and systemic thinking in the subject of chemistry of second class intermediate school students. The sample of research consisted of 59 students in one intermediate school in Baghdad/Iraq, split into two groups; experimental and control. The scientific material of the study is related to Chapters II and III of the Science Book for the second Intermediate School for the Year (2019-2020). The scientific test is composed of 25 test items whilst the second instrument for research related to systematic thinking test consisted of 12 items. The results of the research showed that the use of Fryer's chemistry-teaching strategy has increased achievement an
... Show MoreBackground: This study evaluated the influence of different fiber formulations incorporation in resin composite on cuspal deflection (CD) of endodontically-treated teeth with mesio-occluso-distal (MOD) cavities. Materials and Methods: Thirty-two freshly extracted maxillary premolar teeth received MOD cavity preparation followed by endodontic treatment using single cone obturation technique, and divided into: Group I: direct composite resin only using a centripetal technique, Group II: direct composite resin with short fiber-reinforced composite (everX Flow), Group III: direct composite resin with leno wave ultra-high molecular weight polyethylene (LWUHMWPE) fibers placed on the cavity floor, and Group IV: direct composite resin with LWUHMWP
... Show More