Background: The immune system of the oral cavity suffers alterations due to fixed orthodontic treatment which act as potent stimulus for oral secretory immunity. The aims of this study are to estimate the effect of fixed orthodontic appliance on the level of salivary sIgA at different time intervals, and to verify the gender difference. Materials and method: The patient's history, clinical examination, and fixed orthodontic appliances were placed for 30 Iraqi orthodontic adult patients had class II division 1 and/ or class I malocclusion (15 males and 15 females) aged 18-25 years old. The unstimulated whole saliva was collected from each sample immediately before wearing fixed appliance (control group T0 as base line), and after 2 weeks (T1),1 month (T2), and 1year (T3) of wearing fixed orthodontic appliance. The levels of salivary sIgA were measured by Enzyme Linked Immunosorbant Assay kit (ELISA). Results: The mean value of salivary sIgA was elevated at T1 and reached the peak at T2 followed by declined at T3 to reach near the normal value at T0 (base line). Repeated measure ANOVA test showed statistically highly significant difference among four time intervals. The Bonferroni test after repeated measure ANOVA test showed highly statistical significant difference between each two time intervals except between T0 and T3 show significant difference. In addition there were no significant gender differences. Conclusion: In this study one can conclude that fixed orthodontic appliance acts as an immunological stimulant in the oral cavity that changes the level of salivary sIgA which evaluate the immunity status in the oral cavity.
The present study was conducted as atrial to treat secondary hydatidosis in white mice of species Mus musculus. (Balb/c strain), experimentally infected with secondary hydatid cysts of sheep origin. The immunization process was carried by using CF/PS antigen which consist hydatid cyst fluid (CF) antigen, and protoscolices (PS) antigen mixed together and by using two concentrations 7.5, 15 mg/ml. Then derivatives of Benzimidazole, Mebendazole (M) and drugs Albendazole (A) were used 10 and 40 μm/gm body weight respectively. The mixture of drugs was used one week after challenged dose. Criteria taken into consideration to define the activity of the immunization and chemotherapy in this study were reduction in the numeral of cysts, the coeffic
... Show MoreBackground: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t
... Show MoreBackground: Sonographic examination is an important tool in assessment of normal and abnormal cervical lymph nodes. The aim of the study is to assess the distribution and the characteristic features of normal cervical lymph nodes in a sample of Syrian population. Materials and Methods: Fifty healthy Syrian subjects (25 men and 25 women) with an age of 20 -60years old, who had their cervical lymph nodes examined by ultrasound. Three hundred and two lymph nodes were detected. Lymph nodes were evaluated for their number, size, site, echogenic hilus, shape, as well as for the border sharpness. The subjects were categorized by age into four groups, (20 -30, 31 - 40 , 41 - 50 , 51- 60 years ). Statistical analysis of data was done using SP
... Show MoreObjective. This study aimed to evaluate the orthodontic bond strength and enamel-preserving ability of a hydroxyapatite nanoparticles-containingself-etch system following exposure to various ageing methods. Materials and Methods. Hydroxyapatite nanoparticles (nHAp) were incorporated into an orthodontic self-etch primer (SEP, Transbond™ plus) in three different concentrations (5%, 7%, and 9% wt) and tested versus the plain SEP (control) for shear bond strength (SBS), adhesive remnant index (ARI) scores, and enamel damage in range-finding experiments using premolar teeth. The best-performing formulation was further exposed to the following four artificial ageing methods: initial debonding, 24 h water storage, one-month water stora
... Show MoreApplying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melti
... Show MoreBackground: Hypertension is probably the most important public health problem around the world. People with periodontal disease may be at greater risk of hypertension. The inflammatory effects of periodontal disease help to promote endothelial dysfunction in arteries which may lead to changes in blood pressure. Salivary MMP-8 has been associated with both periodontal disease and prevalent hypertension. Aim of study: This study was conducted to measure salivary matrix metalloproteinase - 8, in relation to periodontal health condition among a group of patients with hypertension in comparison with control group. Materials and methods: Ninety subjects, aged 45-50 years old were included in this study, seeking treatment for chest pain in Ibn-A
... Show MoreABSTRACT Background: work-related musculoskeletal disorders represent an important occupational health issues among dentists especially neck and low back complaints. Biomarkers of tissue damage as results of occupational physical demands could be used for detection of work related musculoskeletal disorders. Aim: The aim of this study was to assess work- related musculoskeletal disorders, physical work load index, selected salivary biomarkers (Creatine kinase and C - reactive protein) and to find the relation among them. Subjects and Methods: Study participants are consisted of 112 dentists. They were selected from college of dentistry /Baghdad University, health care center in Bagdad city. They were of both gender and aged between 40-45 yea
... Show MoreABSTRACT Background: Dental caries is a most common social and intractable infectious disease in human. Saliva is critical for preserving and maintaining oral health and salivary elements had many effects on caries experience. Aim of study: This study was conducted to assess dental caries severity by age and gender and their relation to salivary zinc and copper among a group of adults aged (19-22) years. Materials and methods: After examination eighty persons aged 19-22 years of both gender. Caries severity was documented according to DMFS index. Stimulated salivary samples were collected and chemically analyzed under standardized condition to detect salivary elements zinc and copper. Concentrations of Zinc and copper were measured by using
... Show MoreStick- slip is the continuous stopping& release of the Bit/BHA due to the irregular down-hole rotation prompted by the existing relationship between the friction torque and the torque applied from the surface to free the bit.
Friction coefficient between BHA and wellbore is the main player of stick slip amount, which can be mitigated by support a good lubricators as additives in drilling mud.
Mathematical (or empirical) solves should be done through adjusting all parameters which supposed to reduce stick- slip as low as possible using different models, one of the main parameters is drilling mud. As per Nanoparticles drilling fluid is a new technology that offers high performance
... Show More