Background: The oral cavity is considered as a complex ecological niche, its complex microbial community is reflected to it. Streptococcus mutans has been implicated as one of the major etiological factor of dental caries. Tooth surfaces colonized with Streptococcus mutans are at a higher risk for developing caries, while lactobacilli are considered as the secondary invaders, not initiators of the carious lesion. The main purpose of this study was to correlate the dental caries (for primary and permanent teeth) in the upper jaw with the streptococcus mutans and lactobacilli count in the dental plaque and saliva, also to correlate the dental caries (for primary and permanent teeth) in the lower jaw with the streptococcus mutans and lactobacilli count in the saliva. Materials and methods: Forty seven children aged 5-9 years old were selected for this study. Dental caries recording was carried out by the dmfs index (decayed, missed, filled surfaces for primary teeth) to inspect the primary teeth and DMFS index (decayed, missed, filled surfaces for permanent teeth) to inspect the permanent teeth, by using the dental mirror and explorer. Collection of salivary samples was performed in the morning between (10-11) a.m. at least one hour after breakfast, then normal saline was added to have tenfold dilutions, for the purpose of full colony counting of the caries related microorganisms (streptococcus mutans and lactobacilli), then inoculation was done in the special selective media (for the streptococcus mutans is Mitis-Salivarius-Bacitracin agar, and for the lactobacilli is Rogosa agar). Counting of the colonies of the bacteria were estimated by the aid of dissection microscope Results: The highest level of dmfs means was found in primary upper teeth, it was 17.6383 ± 10.10 while for the permanent teeth the mean of DS and DMFS was highest in the lower teeth, it was 0.7391 ± 1. Pearson correlation was used to show the correlation between the ds and dmfs of upper and lower primary teeth with the level of streptococcus mutans in saliva (sm. Sal) and lactobacillus in saliva ,there was a significant correlation between the ds and dmfs for upper primary teeth at level 0.01 (2-tailed), and there was negative correlation between dsl and level of streptococcus mutans in saliva (sm. Sal) also there was negative correlation between dmfs for upper and lower primary teeth with level of streptococcus mutans in saliva, also the correlation between lactobacillus level in plaque with streptococcus level in plaque was negative, while for upper permanent teeth the correlation was negative with both type of bacteria level in plaque with the DSU and DMFSU Conclusion: The caries activity was more prominent in upper teeth than lower teeth, levels of streptococcus mutans were not associated with high caries activity, which emphasizes and consistent with the fact that the dental caries is a multifactorial disease, related to many factors.
The research aims to identify the possibility of applying environmental fines to commercial shops and restaurants to reduce the environmental pollution represented by the wastes generated from them. The research sample was divided into two groups, including the first (20) commercial shops (meat shops and slaughter it, fruits & vegetables, legumes and accessories) and second (30) Restaurant in the city of Baghdad on both sides of Karkh and Rusafa. The quality of the waste was classified into carton, plastic, aluminum, glass, paper, cork and food waste. The study revealed the possibility of applying environmental fines to restaurants and shops to reduce the waste generated from them throughout the year and to apply continuous monitorin
... Show MoreThe present study aimed to look for the differences in the oxidative stress status in sera and saliva samples of type 2 diabetic Iraqi patients with and without proliferative diabetic retinopathy. As well as to look for the possibility whether this status can be measured in saliva as an alternative sample to that of serum, hence to achieve that total oxidant status, total antioxidant status and oxidative stress index were measured in both sera and saliva samples of two groups of patients with type 2 diabetes mellitus and the healthy individuals. Upon the comparison between patients without proliferative diabetic retinopathy and the control sample the results showed presence of a significant increase (p < 0.05) of total oxidant st
... Show MoreBackground: Systemic sclerosis (SSc) is a chronic autoimmune illness, which is consider by three main features: Sclerotic changes in the skin and internal organs, Vasculopathy of small blood vessels, Particular autoantibodies (1). The most important autoantibodies appeared significantly in SSc patients are anti-topoisomerase I autoantibody (Scl-70), anti-centromere autoantibody (ACA), and anti-RNA polymerase III autoantibody (RNAP3) (2). Anti-centromere antibodies (ACA) are infrequent in rheumatic conditions and in healthy persons but occur commonly in limited systemic sclerosis (CREST syndrome), and rarely appeared in the diffuse form of systemic sclerosis (3). Anti-Ro/SSA and antiLa/SSB, antibodies directed against Ro/La ribonucleoprot
... Show MoreAromatic hydrocarbons present in Iraqi national surface water were believed to be raised principally from combustion of various petroleum products, industrial processes and transport output and their precipitation on surface water.
Polycyclic aromatic hydrocarbons (PAHs) were included in the priority pollutant list due to their toxic and carcinogenic nature. The concern about water contamination and the consequent human exposure have encouraged the development of new methods for
PAHs detection and removal.
PAHs, the real contaminants of petroleum matter, were detected in selected sites along Tigris River within Baghdad City in summer and winter time, using Shimadzu high performance liquid chromatography (HPLC) system.
Analysi
The concentration of radon gas in the samples for drinking water and wells in the same place from selected homes in which wells were built in the Hay-al-Bayaa region of Baghdad was measured, by using a CR-39 nuclear track detector. It turns out that the maximum value of the concentration of radon in drinking water was 3.83 Bq/L, and the lowest was 2.30 Bq/L. As for the estimation of radon gas concentration in well water samples, the highest value was 5.6 Bq/L, while the lowest one was 3.1 Bq/L. In order to assess the committed effective dose received by the public due to the inhalation of radon gas. The highest value of the annual effective dose in drinking water was recorded in Al-Bayaa region, which is equal to 14.30 μSv/y, while th
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,ind
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -
... Show MoreChoosing an appropriate impression material is a challenge for many dentists, yet an essential component to provide an excellent clinical outcome and improve productivity and profit. The purpose of present study was to compare wettability, tear strength and dimensional accuracy of three elastomeric impression materials, with the same consistencies (light-body). Three commercially available light body consistency and regular set 3M ESPE Express polyvinylsiloxane (PVS), 3M ESPE Permadyne polyether (PE), and Identium (ID), impression materials were comparedTear strength test, contact angle test and linear dimensional accuracy were evaluated for three elastic impression material. Among the three experimental groups PE impression materia
... Show More