Background: The oral cavity is considered as a complex ecological niche, its complex microbial community is reflected to it. Streptococcus mutans has been implicated as one of the major etiological factor of dental caries. Tooth surfaces colonized with Streptococcus mutans are at a higher risk for developing caries, while lactobacilli are considered as the secondary invaders, not initiators of the carious lesion. The main purpose of this study was to correlate the dental caries (for primary and permanent teeth) in the upper jaw with the streptococcus mutans and lactobacilli count in the dental plaque and saliva, also to correlate the dental caries (for primary and permanent teeth) in the lower jaw with the streptococcus mutans and lactobacilli count in the saliva. Materials and methods: Forty seven children aged 5-9 years old were selected for this study. Dental caries recording was carried out by the dmfs index (decayed, missed, filled surfaces for primary teeth) to inspect the primary teeth and DMFS index (decayed, missed, filled surfaces for permanent teeth) to inspect the permanent teeth, by using the dental mirror and explorer. Collection of salivary samples was performed in the morning between (10-11) a.m. at least one hour after breakfast, then normal saline was added to have tenfold dilutions, for the purpose of full colony counting of the caries related microorganisms (streptococcus mutans and lactobacilli), then inoculation was done in the special selective media (for the streptococcus mutans is Mitis-Salivarius-Bacitracin agar, and for the lactobacilli is Rogosa agar). Counting of the colonies of the bacteria were estimated by the aid of dissection microscope Results: The highest level of dmfs means was found in primary upper teeth, it was 17.6383 ± 10.10 while for the permanent teeth the mean of DS and DMFS was highest in the lower teeth, it was 0.7391 ± 1. Pearson correlation was used to show the correlation between the ds and dmfs of upper and lower primary teeth with the level of streptococcus mutans in saliva (sm. Sal) and lactobacillus in saliva ,there was a significant correlation between the ds and dmfs for upper primary teeth at level 0.01 (2-tailed), and there was negative correlation between dsl and level of streptococcus mutans in saliva (sm. Sal) also there was negative correlation between dmfs for upper and lower primary teeth with level of streptococcus mutans in saliva, also the correlation between lactobacillus level in plaque with streptococcus level in plaque was negative, while for upper permanent teeth the correlation was negative with both type of bacteria level in plaque with the DSU and DMFSU Conclusion: The caries activity was more prominent in upper teeth than lower teeth, levels of streptococcus mutans were not associated with high caries activity, which emphasizes and consistent with the fact that the dental caries is a multifactorial disease, related to many factors.
One of the main parts in hydraulic system is directional control valve, which is needed in order to operate hydraulic actuator. Practically, a conventional directional control valve has complex construction and moving parts, such as spool. Alternatively, a proposed Magneto-rheological (MR) directional control valve can offer a better solution without any moving parts by means of MR fluid. MR fluid consists of stable suspension of micro-sized magnetic particles dispersed in carrier medium like hydrocarbon oil. The main objectives of this present research are to design a MR directional control valve using MR fluid, to analyse its magnetic circuit using FEMM software, and to study and simulate the performance of this valve. In this research, a
... Show MoreAbstract In the current contribution, a novel binuclear nickel(II) and zinc(II) complexes were prepared from a hexadentate ligand prepared via condensation of 3,3'-Bipyridine-6,6'-dicarbaldehyde , 2-amino-5-chlorobenzaldehyde and 2-Aminophenol .The symmetric ligand (H2DTPE) and its metal complexes were illustrated utilizing various techniques of physicochemical containing magnetic moment, analytical analysis and spectroscopy of mass, IR, 13C and 1H NMR, TGA and UV-Vis. The particles of MO Nanoscale were created from the labeled complex applying the ways of pyrolysis and utilizing methods of XRD, FT-IR, and FE-SEM, that specified close compatibility with the typical pattern for nanoparticles of NiO, ZnO and appeared the reasonable size in
... Show MoreKirchhoff Time migration was applied in Pre and Post-Stack for 2D seismic survey for line AJ-99N, that is located in Ajeel oilfield in Salah Al-Din Governorate, Central Iraq. The process follows several accurate steps to reach the final time migration stage. The results of applied time migration give an accurate image for the Ajeel anticline reservoir and to improve the signal to noise ratio. Pre-Stack shows a clearer image for the structure in the study area, and the time-frequency analysis insure the result.
Abstract
The current study deals with the effect of N-Diethylnitrosamine (DEN) induced traumatic brain injury on male albino rats, as well as the outcome results of treatment with paclitaxel nanoparticles for a period of 8 weeks with two-week intervals is the concern of the present study. Mean body weight, as well as brain weight, was considered as the main parameters whereas a detailed immunohistochemical study on rat brain sections was performed. Astrocytic biomarkers for the diagnosis of astrocytes by fibrillary glial acidic protein (GFAP). Neuronal GFAP staining used for various broke sections were forwarded. Comparison and Contrast of all these parameters in all steps of the experiment had been discussed. The
... Show MoreThe main object of the current work was to determine the antifungal efficiency of secondary metabolites product called synephrine that extracted from Citrus sinesis peels and the ability of synephrine to biosynthesis gold nanoparticles from HAucl4 which consider environmentally favourable method, then determine their activity against pathogenic human dermatophyte. The identification of synephrine done by Thin layer chromatography (TLC), High Performance Liquid Chromatography (HPLC) and The Fourier Transform Infrared (FTIR). The characterization of gold nanoparticles by using Ultra Violet-Visible Spectroscopy (UV-Vis), Field – Emission Scanning Electron Microscopy (FESEM) and Fourier Transform Infrared (FTIR), confirmed the biosynt
... Show MoreThe research work present a sensitive, accurate and fast developed for the determination of oxonium ion (HCl, H2SO4 , HClO4 and tartaric acid). It relies on the formation free iodine molecule from the I--IO3--H3O+ reaction which react with fluorescein sodium salt solution causing to quench the fluorescence light (continuous fluorescence) when irradiated by laser source at 405nm. Optimum parameters were studied giving to specify the chemical and physical parameters. Two line manifold was used. The flow rate of 1.3 and 1.5 mL/min was used, 35μL sample volume no.1 and sample volume no.2 , linear dynamic range extend from 0.05-7, 0.05-7, 0.1-10 and 0.1-10 mMol.l-1 with correlation coefficient of 0.9933, 0.9964, 0.9984 and 0.9973 for HCl, H2
... Show MoreAbstract:
Objective: To self-evaluate the effect of SBAR (Situation, Background, Assessment, and Recommendation) educational program on nurse and midwives practices in maternal health report documentation accuracy.
Methods: A quasi- experimental design was carried with the application of pre- post test for nurses and midwives’ knowledge and practices regarding SBAR communication tool. The study was held in Al-Elwia maternity teaching hospital, Al –Karckh maternity hospital and Al-Yarmouk teaching Hospital. purposive sample as it was convenient with inclusion criteria consisted of (84) nurse and midwives. The questionnaire comprised of demographic data, nurses- midwives practices of SBAR using (5) level Likert scale for assessme
Obliquely deposited (70o) Bi, Sb, and Bi-Sb alloy thin films have been prepared by thermal
resistive technique. Structural properties of these films were studied using XRD. Their resistance and
voltage responsivity for Nd:YAG and CO2 laser pulses have been recorded as function of operating
temperature between 10 oC and 120 oC. It was found that the maximum responsivity for these detectors
can be obtained at 75 oC. On the other hand, the dependence of responsivity on the width of detectors was
investigated.