Background: The healing period for bone–implant contact takes 3–6 months or even longer. Application of Escherichia coli-derived recombinant human bone morphogenetic protein-2 (ErhBMP-2) to implant surfaces has been of great interest on osseointegration due to its osteoinductive potential. The objective of this study was to evaluate the effect of ErhBMP-2 on implant stability. Materials and methods: A total of 48 dental implants were inserted in 15 patients. Twenty four implants coated with 0.5 mg/ml ErhBMP-2 (study group). The other 24 implants were uncoated (control group). Each patient was received at least two dental implants at the same session. Both groups were followed with repeated implant stability measurements by means of resonance frequency analysis at different time intervals (at the time of surgery, then at 6th and 12th week postoperatively). Results: there was no obvious statistically significant difference in mean of implant stability quotient ISQ between study and control groups (P > 0.05) at time of surgery, whereas the mean of ISQ values at 6th and at 12th week postoperatively were statistically highly significant in the study group compared to the control group (p < 0.01). Conclusion: The results of this study reveal that coating dental implants with ErhBMP-2 increases stability when compared with uncoated implants.
The research aims at introducing the principles of six sigma and if it had any effect of the dimensions of six sigma to improve the performance of the dentists and the availability of an appropriate environment in the center Specialist respondent to the application of six sigma principles and how to adopt Specialized Center under the dimensions of the six sigma and if there informed enough with the management methodology six sigma, and if you can adopt six sigma as one of the entrances to reduce medical errors. So Search creating six sigma five dimensions and are (the commitment and support of senior management, the focus on the patient, continuous improvement, training and civil, and infrastructure) as a variable int
... Show MoreBackground: Bone cutter is widely used in the
Middle east area to cut the prepuce during circumcision.
Results :One hundred twenty one male neonates
were included in this study.The mean operative
time (MOT) was 6 minutes, mean time of
healing (MTH) was 5 days, 7 cases (5.9%)
developed early & late complications, 2 (1.7%)
had bleeding, 3 (2.5%) developed infection, 2
(1.7%) developed late complications in the form
of meatal stenosis.
Settings:Al-Yarmouk Teaching Hospital and a
private surgical clinic.
Aim of the study: To assess the safety of
circumcision using bone cutter.
Methods: Over 6 years period from Jan. 2000
till Dec. 2005, one hundred twenty one male
neonates were circumci
The current study was conducted with the aim of fortifying meat burger with the protein isolate extracted from defatted sweetened and unsweetened apricot kernels. The antimicrobial activity of defatted apricot kernels and protein isolates of sweetened and unsweetened kernels against some pathogenic microbes was studied, and it was characterized by its effect on gram-positive bacteria more than gram-negative bacteria. As for its effect on yeast, the inhibition diameter was 4.5 mm at a concentration of 200 mg for the unsweetened protein isolate. As for its effect on mold, the inhibition percentage was between 56.05 65.21% for all samples at a concentration of 100 mg. The sweetened and unsweetened protein isolate was used in the manufact
... Show MoreIn this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calcul
... Show MoreAbstract Objectives: Malocclusion was and remains one of the most common problems which affects the psyche and social status of the individual, so the estimation of the malocclusion severity and needs a percentage of orthodontic treatment of Iraqi patients is the aim of this study. Method: A randomly selected 150 pairs of study models (48 male and 102 female) were involved in this study for patients attending an orthodontic clinic at College of Dentistry/ University of Baghdad seeking for treatment. The DAI scores were collected according to WHO guidelines directly from the study model with a digital caliper, score was calculated using the regression equation of 10 occlusal traits. The dental casts were classified into four groups to determ
... Show MoreTransition metal complexes of Co(II) and Ni(II) with azo dye 3,5-dimethyl-2-(4-nitrophenylazo)-phenol derived from 4-nitoaniline and3,5-dimethylphenol were synthesized. Characterization of these compounds has been done on the basis of elemental analysis,electronic data, FT-IR,UV-Vis and 1 HNMR, as well as magnetic susceptibility and conductivity measurements. The nature of thecomplexes formed were studies following the mole ratio and continuous variation methods, Beer ' s law obeyed over a concentrationrange (1x10 -4 - 3x10 -4 M). High molar absorbtivity of the complex solutions were observed. From the analytical data, thestoichiomerty of the complexes has been found to be 1:2 (Metal:ligand). On the basis of physicochemical data tetrahedral
... Show MoreTHE EFFECT OF SPREACL of KNOWLEDGE ON ETHICS
Background: The desire for an attractive appearing fixed orthodontic appliance fueled the use of ceramic brackets and clear accessories. Elastics are one of the most versatile materials available to orthodontists so studying their effect on the esthetic appearance is important. This an in vivo study, conducted to evaluate the effect of exposing stretched clear elastomeric ligatures to the oral environment from four different companies (OrthoTechnology, Morelli, Ortho Organizer, and Ormco). Materials and Methods: A total of 240 elastomeric modules were examined, 60 modules from each brand. Each of the 60 patients enrolled in the study, received 4 elastomeric modules on the 4 lower incisors, one from each brand. The specimens were placed on t
... Show More