Background: Understanding the pathogenesis and molecular basis of Oral Squamous Cell Carcinoma (OSCC) has increased rapidly over the past few years that is essential to improve patient's prognosis and treatment modalities. The purpose of this study to evaluate the Immunohistochemical expressions of AKT, ATM, AND Cyclin E in oral squamous cell carcinoma Materials and methods: This study was performed on a forty formalin-fixed paraffin-embedded blocks which histopathologically diagnosed as Oral Squamous Cell Carcinoma. All cases were collected from the Histopathological Laboratory from patients treated surgically at Maxillofacial surgery Department at Ramadi Teaching Hospital, Iraq. Results: The immunohistochemical staining of AKT showed positive expression in 38 (95%), ATM showed positive expression in 38(95%) and Cyclin E showed positive expression in 36(90%) of the cases. Conclusion: A statically significant correlation was found regarding the immunohistochemical expression of AKT with tumor grade and stage, Cyclin E with the age group and ATM with the clinical appearance
High cost of qualifying library standard cells on silicon wafer limits the number of test circuits on the test chip. This paper proposes a technique to share common load circuits among test circuits to reduce the silicon area. By enabling the load sharing, number of transistors for the common load can be reduced significantly. Results show up to 80% reduction in silicon area due to load area reduction.
To damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. Double input multiband Power system stabilizers (PSSs) were used to damp out low-frequency oscillations in power system. Among dual-input PSSs, PSS4B offers superior transient performance. Power system simulator for engineering (PSS/E) software was adopted to test and evaluate the dynamic performance of PSS4B model on Iraqi national grid. The results showed
... Show MoreTo damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. Double input multiband Power system stabilizers (PSSs) were used to damp out low-frequency oscillations in power system. Among dual-input PSSs, PSS4B offers superior transient performance. Power system simulator for engineering (PSS/E) software was adopted to test and evaluate the dynamic performance of PSS4B model on Iraqi national grid. The res
... Show More