Preferred Language
Articles
/
jbcd-1423
Mechanical Evaluation of Pure Titanium Dental Implants Coated with a Mixture of Nano Titanium Oxide and Nano Hydroxyapatite
...Show More Authors

Background: The type of dental implant surface is one of many factors that determine the success of implant restoration. This study aimed to study the effect of mixture of nano titanium oxide with nanohydroxyapatite coating of screw shaped CPTi dental implant on bond strength at bone implant interface by torque removal test related to two healing periods (2 and 6 weeks). Materials and methods: Dip coating process was performed to get an even coating layer on CPTi screws. X-ray diffraction (XRD) analysis and microscopical examination were performed on the coating surfaces of the CPTi. The tibia of 10 white New Zealand rabbits was chosen as implantation sites. The tibia of each rabbit received two screws, one was coated with mixture of nanoTio2and nanoHA and the other was coated with nanoHA and a total of 40 screws were implanted. Torque removal test was performed to measure bond strength between implant and bone, after 2 and 6 weeks healing periods. . Results: The results revealed, that the mean removal torque recordings for the mixture of nanoTio2and nanoHA coated screws was significantly greatly than the nanoHA covered screws over the two periods of time(2and6 weeks). There was an increase in the torque value with time. Conclusion: Commercially pure titanium implant coated with mixture of nanoTio2andnanoHApresented an increasing bond strength at bone implant interface than nanoHA , after 2 and 6 weeks (20.13±4.4 N.cm , 26.47±4 N.cm. ) in comparison to nanoHA coating after 2 and 6 weeks (15.16±2.5 N.cm , 20.12±2.3 N.cm) .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
Effect of partial substitution of alkaline oxides with lithium oxide (Li2O) on low-temperature ceramic glaze
...Show More Authors

The research aims to study the effect of adding (Li2O) to an alkaline glaze containing (K2O, Na2O). Although all the alkaline oxides have common properties, each oxide has something that distinguishes it. The molecular weight of (Li2O) is two times less than that of (Na2O) and three times that of (K2O). Therefore, it is added in small proportions. In addition, it is a very strong flux, so it is not used alone, but rather replaces a part of other alkaline oxides. It was added to an alkali glass that matured at a temperature of 980CO in proportions (2.0,1.4,1.2,0.8,0.4%) instead of (Na2O), using lithium carbonate (Li2CO3) as an oxide source. The glazes mixtures were applied to a white pottery body, and the samples were fired and cooled acc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Electrochemical Behavior of Chemical Conversion Coated Aluminum ASA6061 in Chromic Acid
...Show More Authors

The corrosion behavior of bare and chemical conversion coated (through anodizing) aluminum ASA 606 I in stagnant chromic acid solutions . Solutions of 2, 6 & J O wt. % Cr03 at 45°C, have been investigated using polarization technique. The anodizing experiments were conducted under fixed conditions of 35 minute exposure time and 30 volt supplied voltage. The most important feature achieved was the great difference in behavior between the anodic polarization curves for bare and anodized aluminum in different concentrations of chromic acid solutions.

View Publication Preview PDF
Publication Date
Sat Jun 06 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
A comparative study of the mechanical and electrical activities of the heart according to the energy systems of advanced players
...Show More Authors

The study aims to identify the mechanical and electrical activities of the heart according to the energy systems of advanced players and to detect the differences between the energy systems in terms of the mechanical and electrical activities of the heart for advanced players. It was clear from the results of the significance of the differences between the three groups according to the energy systems of the advanced players in all research variables that (the non-oxygenic system "Lactic"), which represents the advanced players in the arches (800 m, 1500 m) was the first in most tests of mechanical and electrical activities of the heart, which is (Margaria-Kalamen, Wingate, systolic muscle strength of the heart FC, Stroke Volume SV

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 08 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Quantitative assessment of Mutans Streptococci adhesion to coated and uncoated orthodontic archwires(In vitro study)
...Show More Authors

Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in steri

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 05 2020
Journal Name
Methods And Objects Of Chemical Analysis
Derivative Spectrophotometric Determination for Simultaneous Estimation of Isoniazid and Ciprofloxacin in Mixture and Pharmaceutical Formulation
...Show More Authors

A simple analytical method was used in the present work for the simultaneous quantification of Ciprofloxacin and Isoniazid in pharmaceutical preparations. UV-Visible spectrophotometry has been applied to quantify these compounds in pure and mixture solutions using the first-order derivative method. The method depends on the first derivative spectrophotometry using zero-cross, peak to baseline, peak to peak and peak area measurements. Good linearity was shown in the concentration range of 2 to 24 µg∙mL-1 for Ciprofloxacin and 2 to 22 µg∙mL-1 for Isoniazid in the mixture, and the correlation coefficients were 0.9990 and 0.9989 respectively using peak area mode. The limits of detection (LOD) and limits of quantification (LOQ) were

... Show More
Publication Date
Fri Dec 29 2017
Journal Name
Al-khwarizmi Engineering Journal
Design And Implementation of Microcontroller Based Curing Light Control of Dental System.
...Show More Authors

In this paper, a microcontroller-based electronic circuit have been designed and implemented for dental curing system using 8-bit MCS-51 microcontroller. Also a new control card is designed while considering advantages of microcontroller systems the time of curing was controlled automatically by preset values which were input from a push-button switch. An ignition based on PWM technique was used to reduce the high starting current needed for the halogen lamp. This paper and through the test result will show a good performance of the proposed system.

 

 

View Publication Preview PDF
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
Behavior of Reinforced Concrete Continuous Beams under Pure Torsion
...Show More Authors

Practically, torsion is normally combined with flexure and shear actions. Even though, the behavior of reinforced concrete continuous beams under pure torsion is investigated in this study. It was performed on four RC continuous beams under pure torsion. In order to produce torsional moment on the external supports, an eccentric load was applied at various distances from the longitudinal axis of the RC beams until failure.

Variables considered in this study are absolute vertical displacement of the external supports, torsional moment’s capacity, angle of twist and first cracks occurrences. According to experimental results; when load eccentricity increased from 30cm to 60cm, the absolute vertical displacement i

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Impact of dome projection on operative steps during clipping of a ruptured pure posteriorly directed posterior communicating artery aneurysms
...Show More Authors

Background: Ruptured posterior communicating artery (PCoA) aneurysms are common; they usually present with subarachnoid haemorrhage (SAH) and oculomotor nerve palsy. The aneurysmal dome projection may influence the safety access and aneurysmal neck clipping. Here, we discuss additional intraoperative steps that may be required to widen the surgical field to ensure safe surgical clipping of a rupture pure posteriorly directed PCoA aneurysm. Case description: A previously healthy 38-year-old male reported sudden severe headache and disturbed level of consciousness with a Glasgow coma scale (GCS) of 13. His initial computed tomography (CT) scan of the head showed SAH in the basal cistern. 3D-constructed CT angiography (CTA) revealed a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jul 01 2019
Journal Name
International Journal Of Pharmaceutical Research
Sensitive Spectrophotometric Determination of Doxycycline in Pure and Dosage Forms using p-Bromanil
...Show More Authors

View Publication
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Kinetic- spectrophotometric Method for the Determination of Naringenin in Pure and Supplements Formulations
...Show More Authors

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref