Preferred Language
Articles
/
jbcd-1423
Mechanical Evaluation of Pure Titanium Dental Implants Coated with a Mixture of Nano Titanium Oxide and Nano Hydroxyapatite
...Show More Authors

Background: The type of dental implant surface is one of many factors that determine the success of implant restoration. This study aimed to study the effect of mixture of nano titanium oxide with nanohydroxyapatite coating of screw shaped CPTi dental implant on bond strength at bone implant interface by torque removal test related to two healing periods (2 and 6 weeks). Materials and methods: Dip coating process was performed to get an even coating layer on CPTi screws. X-ray diffraction (XRD) analysis and microscopical examination were performed on the coating surfaces of the CPTi. The tibia of 10 white New Zealand rabbits was chosen as implantation sites. The tibia of each rabbit received two screws, one was coated with mixture of nanoTio2and nanoHA and the other was coated with nanoHA and a total of 40 screws were implanted. Torque removal test was performed to measure bond strength between implant and bone, after 2 and 6 weeks healing periods. . Results: The results revealed, that the mean removal torque recordings for the mixture of nanoTio2and nanoHA coated screws was significantly greatly than the nanoHA covered screws over the two periods of time(2and6 weeks). There was an increase in the torque value with time. Conclusion: Commercially pure titanium implant coated with mixture of nanoTio2andnanoHApresented an increasing bond strength at bone implant interface than nanoHA , after 2 and 6 weeks (20.13±4.4 N.cm , 26.47±4 N.cm. ) in comparison to nanoHA coating after 2 and 6 weeks (15.16±2.5 N.cm , 20.12±2.3 N.cm) .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Procaine penicillin in pure and pharmaceutical formulations using metol
...Show More Authors

A simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
Effect of Lupeol on Inducing the Nitric Oxide Production in Macrophages Infected with Leishmania Donovani
...Show More Authors

Visceral leishmaniasis is a neglected tropical disease on the rise in different regions of Iraq, especially in areas with poor hygiene and among refugee populations. The effectiveness of existing chemotherapy for leishmaniasis is constrained by its high toxicity, cost, and the development of drug resistance. The current research examined various concentrations (ranging from 125 to 1000 μM) of lupeol to evaluate its ability to boost the generation of nitric oxide, which has anti-leishmanial properties, in an ex-vivo macrophage model. Griess assay was used to detect the nitric oxide (NO) production in Leishmania donovani infected U937 cell-line macrophages along 24 and 48 hours post treated. The nitric oxide concentration was signifi

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Some Methods for Estimating the Scheff'e Model of the Mixture
...Show More Authors

Because of the experience of the mixture problem of high correlation and the existence of linear MultiCollinearity between the explanatory variables, because of the constraint of the unit and the interactions between them in the model, which increases the existence of links between the explanatory variables and this is illustrated by the variance inflation vector (VIF), L-Pseudo component to reduce the bond between the components of the mixture.

    To estimate the parameters of the mixture model, we used in our research the use of methods that increase bias and reduce variance, such as the Ridge Regression Method and the Least Absolute Shrinkage and Selection Operator (LASSO) method a

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat May 01 2021
Journal Name
Civil Engineering Journal
The Suitability of Bailey Method for Design of Local Asphalt Concrete Mixture
...Show More Authors

The study investigated the behaviour of asphalt concrete mixes for aggregate gradations, according to the Iraqi specification using the Bailey method designed by an Excel spreadsheet. In mixing aggregates with varying gradations (coarse and fine aggregate), The Bailey method is a systematic methodology that offers aggregate interlocking as the backbone of the framework and a controlled gradation to complete the blends. Six types of gradation are used according to the bailey method considered in this study. Two-course prepared Asphalt Concrete Wearing and Asphalt Concrete binder, the Nominal Maximum Aggregate Sizes (NMAS) of the mixtures are 19 and 12.5 mm, respectively. The total number of specimens was 240 for both layers (15 samp

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 01 2002
Journal Name
Iraqi Journal Of Physics
Pure 90Sr External Bremsstrahlung Spectra
...Show More Authors
Beta particles emitted from a 90Sr/90Y source have two different end point energies; 546 keV for 90Sr and 2274 keV for 90Y. The external bremsstrahlung (EB) photons produced by the complete absorption of 90Sr/90Y betas stopped in thick targets will therefore be convoluted with both 90Sr and 90Y sources at the energy range less than 546 keV. In this investigation spectral distribution of pure 90Sr EB was deduced for the first time from the matching between the measured spectrum of EB by 90Sr/90Y and the Spectral distribution of 90Y of the exact numerical screened calculations of Pratt et al.
for
... Show More
View Publication Preview PDF
Publication Date
Sun Dec 01 2013
Journal Name
Baghdad Science Journal
Notes on Approximately Pure Submodules
...Show More Authors

Let R be a commutative ring with identity 1 and M be a unitary left R-module. A submodule N of an R-module M is said to be approximately pure submodule of an R-module, if for each ideal I of R. The main purpose of this paper is to study the properties of the following concepts: approximately pure essentialsubmodules, approximately pure closedsubmodules and relative approximately pure complement submodules. We prove that: when an R-module M is an approximately purely extending modules and N be Ap-puresubmodulein M, if M has the Ap-pure intersection property then N is Ap purely extending.

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 15 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Quantitative assessment of Mutans Streptococci adhesion to coated and uncoated orthodontic archwires(In vitro study)
...Show More Authors

Background: The development of orthodontic biomaterials that attract less biofilm has been a goal for decades. Adhesion and colonization of cariogenic streptococci are considered to play key roles in the development of enamel demineralization related to orthodontic materials. The aim of this study was to quantitatively evaluate the Mutans streptococci adhesion to coated orthodontic archwires (Epoxy and Teflon) and uncoated archwires (stainless steel and nickel-titanium) with respect to incubation time in the presence and absence of saliva. Material and Method: Six types of archwires stainless steel and nickel titanium with two type of coating (Epoxy, Teflon) were used in this study. Twelve specimens of each archwire were incubated in steri

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 10 2018
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified with Functionalized Graphene Oxide
...Show More Authors

Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial (GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration Γ of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket was obtained as 5.39×

... Show More
Preview PDF
Publication Date
Thu May 17 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Scan Rate and pH on Determination Amoxilline Using Screen Printed Carbon Electrode Modified With Functionalized Graphene Oxide
...Show More Authors

  Graphene oxide GO was functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (ASTT) to obtain GOT. GOT characterized by FT-IR, XRD.via modification of the working electrode of the SPCE with the prepared nanomaterial ( GOT) the effect of scan rate and pH on the determination of Amoxilline (AMOX) was studied using cyclic voltammetry. AMOX show various responses at pH ranging from 2 to 7 and also was observed sharp increase in the oxidation peaks in the pH 3. The formal potential (midpoint) for AMOX was highly pH-dependent. From the effect of scan rate, surface coverage concentration  of electroactive species the values of the electron transfer coefficient and the electron transfer constant rate ket

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Methods And Objects Of Chemical Analysis
Partial Least Squares Method for the Multicomponent Analysis of Antibacterial Mixture
...Show More Authors

This study's objective is to assess how well UV spectrophotometry can be used in conjunction with multivariate calibration based on partial least squares (PLS) regression for concurrent quantitative analysis of antibacterial mixture (Levofloxacin (LIV), Metronidazole (MET), Rifampicin (RIF) and Sulfamethoxazole (SUL)) in their artificial mixtures and pharmaceutical formulations. The experimental calibration and validation matrixes were created using 42 and 39 samples, respectively. The concentration range taken into account was 0-17 μg/mL for all components. The calibration standards' absorbance measurements were made between 210 and 350 nm, with intervals of 0.2 nm. The associated parameters were examined in order to develop the optimal c

... Show More
Scopus (2)
Scopus Clarivate Crossref