Background: Platelet-rich fibrin (PRF) is a simple, low cost and minimally invasive way to obtain a natural concentration of autologous growth factors and is currently being widely experimented in different fields of medicine for its ability to aid the regeneration of tissue with a low healing potential. Fields of application are sports medicine, orthopedics, dentistry, dermatology, ophthalmology, plastic and maxillofacial surgery, etc. The rationale for using platelets in so many fields for the treatment of different tissues is because PLTs constitute a reservoir of critical GFs and cytokines, which may govern and regulate the tissue healing process that is quite similar in all kinds of tissues. Materials and Methods: Screw titanium implants inserted in the femurs of the thirty two adult rats. The right side is considered as experimental groups and the left side considered as control groups. Autologous platelet rich fibrin matrix applicated with the right screw implants . The sample divided into four groups, eight rats are sacrificed at four interval 3days, 7days, 2weeks, and 6weeks respectively. Histological, immunohistochemical (PDGF-A&IGF-1), and radio graphical were studied for each interval. Results: Histological examination showed the acceleration of bone formation and more rapid healing process in the screw implant with PRFM than in the control implant. Radio graphical examinations showed that the process of osseointegration started after 2weeks and complete radio opacity around the titanium implant after 6weeks. Immunohistochemical findings revealed high positive expression for IGF and PDGF in experimental implant in comparison to control one. Conclusion: This study was illustrated that PRFM material was osseo inductive material that enhances the osseointegration process in titanium implant site in comparison to the normal physiological healing process. The results show a positive effect of PRFM and it can be suggested for beneficial use in the practice of dentistry implantation, periodontics, oral surgery since it enhance osseointegration, reduce the period of patient suffering and the incidence of post implant complications.
The aim of the study was extraction of arial part of Euphorbia cyathophora constituents with methanol and evaluate its effect on mitotic index and total chromosomal aberration bone marrow cell and spleen cell in mice 200 gm of E. cyathophora fine powder was defatted then extracted by cold maceration 80% ethanol for seven days. The extract was filtered and dried in a rotary evaporator then the dried extract was suspended with water and consecutively extracted using chloroform, ethyl acetate for each. The aqueous layer was then mixed with 100ml methanol. These fractions are dried under reduced pressure to obtain the dry extract. Twenty-four Albino mice were used for the experiment. The animals were divided into four groups: Gr
... Show Moreraqi species of (Euphorbia lathyris F. Euphorbiaceae) have been used in the present study to evaluate genotoxicity of petroleum ether fraction in two doses (100mg/kg and 200mg/kg) on bone marrow cells in mice for seven successive days, comparing their effects with a positive control (methotrexate at a dose 20 mg/kg). Both doses of petroleum ether fraction of Euphorbia Lathyris significantly decrease mitotic index (P<0.05) compared to dimethylsulfoxide (negative control) group. For total chromosomal aberration, the petroleum ether fraction of Euphorbia lathyris (in both doses) produced significant increase (P<0.05) compared to dimethyl sulfoxide (negative control) group .at the same time, 20mg/kg methotrexate significantly increases (P<0.05)
... Show MoreIntroduction: Carrier-based gutta-percha is an effective method of root canal obturation creating a 3-dimensional filling; however, retrieval of the plastic carrier is relatively difficult, particularly with smaller sizes. The purpose of this study was to develop composite carriers consisting of polyethylene (PE), hydroxyapatite (HA), and strontium oxide (SrO) for carrier-based root canal obturation. Methods: Composite fibers of HA, PE, and SrO were fabricated in the shape of a carrier for delivering gutta-percha (GP) using a melt-extrusion process. The fibers were characterized using infrared spectroscopy and the thermal properties determined using differential scanning calorimetry. The elastic modulus and tensile strength tests were dete
... Show MoreWeed control with chemicals is a challenging process that should be performed in a rational way to reduce their negative impact on the surrounding environment. The growth of artificial intelligence algorithms encourages researchers to develop smart spraying robots that detect and spray weeds and distinguish them from the main crop which leads to sustainable use of these chemicals and achieves some of the sustainable development goals. However, few studies are available to comprehensively compare different versions of YOLO algorithm to detect weed. In this research, seven versions of YOLO algorithms were evaluated for their performance to detect and spray four t
Background: Assessment of function of the right side of the heart in cases of left ventricular dysfunction has been widely studied but the sensitive and specific echocardiographic parameter to be tested is still a matter of controversy. Right ventricular function is related to left ventricular function by ventricular independence so function of both should be assessed carefully. The objective of this study was to evaluate the effects of left ventricular systolic dysfunction on right ventricular systolic and diastolic functions and pulmonary pressure using conventional and tissue Doppler echocardiography. Patients and Methods: Sixty patients (39 males and 21 females) with heart failure due to left ventricular systolic dysfunction
... Show MoreCommercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concent
... Show More