Background: Proper cleaning and shaping of the whole root canal space have been recognized as a real challenge, particularly in oval-shaped canals.This in vitro study was conducted to evaluate and compare the efficiency of different instrumentation systems in removing of dentin debris at three thirds of oval-shaped root canals and to compare the percentage of remaining dentin debris among the three thirds for each instrumentation system. Materials and methods: Fifty freshly extracted human mandibular molars with single straight oval-shaped distal root canals were randomly divided into five groups of ten teeth each. Group One: instrumentation with ProTaper Universal hand instruments, Group Two: instrumentation with ProTaper Universal rotary instruments, Group Three: instrumentation with Revo-Srotary instruments, Group Four: instrumentation withTwisted rotary files and Group Five: instrumentation with Self-Adjusting Files (SAF). Sodium hypochlorite (3%) was used as an irrigant for all groups. After canals preparation, the roots were split longitudinally and photographed with a professional digital camera. The images of root sections were then magnified to 100x and the percentage of remaining dentin debris calculated for the apical, middle and coronal thirds by dividing the pixels occupied by debris at each third by the total pixels representing the entire area of the canal using Adobe Photoshop CS6. Data were analyzed statistically by ANOVA and LSD at 1% and 5% significant levels. Results: Both ProTaper hand and ProTaper rotary files resulted in significantly cleaner canals than Revo-S and Twisted rotary files at the middle and coronal thirds. The Self-Adjusting Files produced significantly cleaner canals at the three thirds than all the other groups. The coronal and middle thirds showed a greater amount of remaining dentin debris than the apical third for all groups except a non-significant difference found between the apical and middle thirds in SAF group. Conclusion: The Self-Adjusting Files allowed more efficient cleaning of oval-shaped root canals than hand and rotary instruments
Abstract:
The internal audit is considered the safety valve for senior management in all institutions. It aims to protect property, and raise the efficiency and effectiveness of the administrative performance, by following up on compliance with laws and instructions and the application of regulations in a way that increases the administrative performance of the department. The internal audit is possible to determine Weaknesses or imbalances in the administrative performance. To achieve this goal, an analytical descriptive methodology was adopted. The Baghdad Health Department / Al-Rosana was considered as society for this s
... Show MoreIntroduction: Carrier-based gutta-percha is an effective method of root canal obturation creating a 3-dimensional filling; however, retrieval of the plastic carrier is relatively difficult, particularly with smaller sizes. The purpose of this study was to develop composite carriers consisting of polyethylene (PE), hydroxyapatite (HA), and strontium oxide (SrO) for carrier-based root canal obturation. Methods: Composite fibers of HA, PE, and SrO were fabricated in the shape of a carrier for delivering gutta-percha (GP) using a melt-extrusion process. The fibers were characterized using infrared spectroscopy and the thermal properties determined using differential scanning calorimetry. The elastic modulus and tensile strength tests were dete
... Show MoreIn this study, successive electrocoagulation (EC) and electro-oxidation (EO) processes were used to minimize some of the major pollutants in real wastewater, such as organics (detected by chemical oxygen demand (COD)), and turbidity. The wastewater utilized in the present study was collected from the Midland Refinery Company in Baghdad-Iraq. The performance of the successive batch EC-EO processes was studied by utilizing Graphite and Aluminum (Al) as monopolar anode electrodes and stainless steel (st.st.) as the cathode. The Taguchi experimental design approach was used to attain the best experimental conditions for COD reduction as a major response. Starting from chemical oxygen demand COD of (600 ppm), the effects of current densi
... Show MoreIn this study, successive electrocoagulation (EC) and electro-oxidation (EO) processes were used to minimize some of the major pollutants in real wastewater, such as organics (detected by chemical oxygen demand (COD)), and turbidity. The wastewater utilized in the present study was collected from the Midland Refinery Company in Baghdad-Iraq. The performance of the successive batch EC-EO processes was studied by utilizing Graphite and Aluminum (Al) as monopolar anode electrodes and stainless steel (st.st.) as the cathode. The Taguchi experimental design approach was used to attain the best experimental conditions for COD reduction as a major response. Starting from chemical oxygen demand COD of (600 ppm), the effects of current density (C
... Show Moreملخص البحث باللغة الإنجليزية
The concept of the phenomenon of nuns: an analytical ideological study
Dr. Samia bint Yassin Al-Badri
Department of Islamic Doctrine & Contemporary Ideologies
College of Shariʿah & Islamic Studies
Qassim University
The study of concepts is one of the main pillars of doctrinal studies, in order to understand the formation of the concept, and to understand its contexts in religious sources, in order to be systematically criticized; So, this research came with the title:
The concept of the phenomenon of nuns, an analytical doctrinal study
The study concluded with resu
... Show MorePolarization is an important property of light, which refers to the direction of electric field oscillations. Polarization modulation plays an essential role for polarization encoding quantum key distribution (QKD). Polarization is used to encode photons in the QKD systems. In this work, visible-range polarizers with optimal dimensions based on resonance grating waveguides have been numerically designed and investigated using the COMSOL Multiphysics Software. Two structures have been designed, namely a singlelayer metasurface grating (SLMG) polarizer and an interlayer metasurface grating (ILMG) polarizer. Both structures have demonstrated high extinction ratios, ~1.8·103 and 8.68·104 , and the bandwidths equal to 45 and 55 nm for th
... Show MoreBelgium is one of the countries that headed towards federalism through a peaceful transition, and over a few decades the country has witnessed deep transformations in its institutions, from a unified and central state in the early nineteenth century to a federal union, regional operations began since 1970 up and constitutionally established its diversity Linguistic and regional, the so -called "state reforms" have been implemented, which led to the emergence of political repercussions. The country has suffered about two decades ago, which caused many national governments that are considered to be among the Luxor in the modern political history of Belgium, However, institutional reforms to achieve the stability of the political system began,
... Show MoreBackground: This study was conducted to assess the effect of sonic activation and bulk placement of resin composite in comparison to horizontal incremental placement on the fracture resistance of weakened premolar teeth. Materials and method: Sixty sound human single-rooted maxillary premolars extracted for orthodontic purposes were used in this study. Teeth were divided into six groups of ten teeth each: Group 1 (sound unprepared teeth as a control group), Group 2 (teeth prepared with MOD cavity and left unrestored), Group 3 (restored with SonicFill™ composite), Group 4 (restored with Quixfil™ composite), Group 5 (restored with Tertic EvoCeram® Bulk Fill composite) and Group 6 (restored with Universal Tetric EvoCeram® co
... Show MoreBackground: The aim of this study was to evaluate the effect of three types of light curing devices QTH, LED and Flashmax on the surface microhardness of three types of bulkfill composite resins; Filtek Bulkfill posterior composite ( 3M), Tetric Evo Ceram ( Ivoclar Vivadent) and Sonicfill composite ( Kerr) Materials and methods: Total number of 90 samples was prepared, 30 samples for each type of bulkfill composite, were divided into three main groups, group A: Filtek posterior bulkfil (3M), group B: Tetric Evo Ceram (Ivoclar Vivadent) and group C: contain Sonicfill composite (kerr). Which then divided into three subgroups (n= 10) (1) Samples cured by QTH system (2) Samples cured by LED system and (3) samples cured by Flashmax system the
... Show More