Preferred Language
Articles
/
jbcd-138
A study to compare the efficiency of different instrumentation systems for cleaning oval-shaped root canals (An in vitro study)
...Show More Authors

Background: Proper cleaning and shaping of the whole root canal space have been recognized as a real challenge, particularly in oval-shaped canals.This in vitro study was conducted to evaluate and compare the efficiency of different instrumentation systems in removing of dentin debris at three thirds of oval-shaped root canals and to compare the percentage of remaining dentin debris among the three thirds for each instrumentation system. Materials and methods: Fifty freshly extracted human mandibular molars with single straight oval-shaped distal root canals were randomly divided into five groups of ten teeth each. Group One: instrumentation with ProTaper Universal hand instruments, Group Two: instrumentation with ProTaper Universal rotary instruments, Group Three: instrumentation with Revo-Srotary instruments, Group Four: instrumentation withTwisted rotary files and Group Five: instrumentation with Self-Adjusting Files (SAF). Sodium hypochlorite (3%) was used as an irrigant for all groups. After canals preparation, the roots were split longitudinally and photographed with a professional digital camera. The images of root sections were then magnified to 100x and the percentage of remaining dentin debris calculated for the apical, middle and coronal thirds by dividing the pixels occupied by debris at each third by the total pixels representing the entire area of the canal using Adobe Photoshop CS6. Data were analyzed statistically by ANOVA and LSD at 1% and 5% significant levels. Results: Both ProTaper hand and ProTaper rotary files resulted in significantly cleaner canals than Revo-S and Twisted rotary files at the middle and coronal thirds. The Self-Adjusting Files produced significantly cleaner canals at the three thirds than all the other groups. The coronal and middle thirds showed a greater amount of remaining dentin debris than the apical third for all groups except a non-significant difference found between the apical and middle thirds in SAF group. Conclusion: The Self-Adjusting Files allowed more efficient cleaning of oval-shaped root canals than hand and rotary instruments

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Human Skin WoundWelding Using 980 nm Diode Laser: an in Vitro Experimental Study
...Show More Authors

Laser assisted skin wound closure offers many distinct advantages over conventional closure
techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for
Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in
welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human
skin obtained from the discarded panniculus of an Abdominoplasty operation were tried to be laser
welded using a 4 mm spot diameter laser beam from a 980 nm diode laser at different laser parameters
and modes of action. The tensile strength at the weld site was analyzed experimentally. Although laser
assisted wound welding did

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Coated stainless steel archwires' discoloration measured by computerized system (An in-vitro study)
...Show More Authors

Background: Aesthetic archwires are used to overcome the aesthetic problems of stainless steel wires but the color of the coating layer can be changed with time when exposed to oral environments. The aim of this study was to evaluate the degree of color change of different aesthetic archwires from different companies under different coloring solutions. Materials and Methods: One hundred fifty samples of coated archwires from three companies (Highland, G&H and Dany) were immersed in 5 solutions (artificial saliva, turmeric, tea, coffee and Miranda) to evaluate the degree of color changes after 7, 14 and 21 days using visible spectrophotometer. Data were collected and analyzed using one way ANOVA and post hoc Tukey’s tests. Resu

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Efficiency Study of Two Adsorbent Materials to Remove Eosin Y Dye from Aqueous Solutions
...Show More Authors

This study was done to find a cheap, available and ecofriendly materials that can remove eosin y dye from aqueous solutions by adsorption in this study, two adsorbent materials were used, the shells of fresh water clam (Cabicula fluminea) and walnut shells. To make a comparison between the two adsorbents, five experiments were conducted. First, the effects of the contact time, here the nut shell removed the dye quickly, while the C. flumina need more contact time to remove the dye. Second, the effects of adsorbent weight were examined. The nut shell was very promising and for all used adsorbent weight, the R% ranged from 94.87 to 99.29. However C. fluminea was less effective in removing the dye with R% ranged from 47.59 to 55.39. The thi

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Apr 10 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of en-masse retraction using microimplant versus conventional techniques: An in vitro study
...Show More Authors

Background: The study aimed to investigate the effect of different techniques of en masse retraction on the vertical and sagittal position, axial inclination, rate of space closure, and type of movement of maxillary central incisor. Materials and methods: A typodont simulation system was used (CL II division 2 malocclusion). Three groups were used group 1(N=10, T-loop), group 2(N=10, Time-Saving loop), and group 3(N=10, Microimplant). Photographs were taken before and after retraction and measurements were made using Autodesk AutoCAD© software 2010. Kruskal-Wallis one-way analyses of variance and Mann-Whitney U test (p?0.05) were used. Results: The rate of space closure showed no significant difference among the three groups (p?0.05), whi

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
The efficiency calibration for local manufacturing gamma scanning systems of radioactive waste drums
...Show More Authors

The Local manufacturing scanning gamma system designed in Tuwaitha site for nondestructive assay method of radioactive waste drums, where it consist of two main parts with their belongings for controlling the of detector and drum movements up-down and rotation respectively. The volume of the used drum is 220 L with 85 cm height. The drum filled with Portland cement. Six cylindrical holes were made within cement drum and distributed in radial arrangement.The152Eu source inserted in these holes individually, to measure the average angular count rate of gamma radiation. The full energy efficiency value for geometry of drum and detector is computed for thirteen photo peaks. The average efficiency represented by the curve of these peaks indic

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Shear Bond Strength of Three Different Brackets Bonded on Zirconium Surfaces (In Vitro Study)
...Show More Authors

Background: With the increased in the demands of adult orthodontics, the challenge of direct bonding to non-enamel surface (zirconium) had been increased. The present study was carried out to compare the shear bond strength of three different brackets (stainless steel, sapphire and composite) bonded to zirconium surface and study the mode of bond failure. Materials and methods: The sample was comprised of 30 models (8mm *6mm*1.5mm) of full contour zirconium veneers. They were divided into three groups according to the brackets type; all samples were treated first by sandblast with aluminum oxide particle 50 µm then coated by z-prime plus primer. A central incisor bracket of each group was bonded to the prepared zirconium surface with lig

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Apr 29 2022
Journal Name
International Journal Of Dentistry
The Effects of Zinc-Containing Mouthwashes on the Force Degradation of Orthodontic Elastomeric Chains: An In Vitro Study
...Show More Authors

Objective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc-containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto-Force and Super Elasto-Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six-time intervals (in

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effects of Different Concentrations of Melatonin on the Time-course of Nitrite–induced Oxidation of Hemoglobin: In vitro Study
...Show More Authors

         Melatonin is a potent scavenger of reactive oxygen species or free radicals like superoxide and hydroxyl radicals. The oxidation of hemoglobin to methemoglobin (meth-Hb) by oxidizing compounds has been widely studied. The present work was designed to evaluate the ability of different concentrations of melatonin to inhibit nitrite–induced oxidation of hemoglobin. Blood samples were obtained from apparently healthy individuals from which erythrocyte hemolysate was prepared. Different concentrations of melatonin (10-9-1.0 mg/ml) were incubated for 10 min with the hemolysate, then to the resultant mixture 1 ml of sodium nitrite (final concentration 0.6 mM) was added, and the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 16 2019
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Antibacterial Efficacy of Silver Nanoparticles as an Irrigant against Enterococcus faecalis In vitro Study
...Show More Authors

Background: Successful root canal therapy depends on thorough chemo mechanical debridement of pulpal tissue, dentin debris and infective microorganisms. Objective: This study aimed to investigate the antibacterial effect of silver nanoparticles, sodium hypochlorite and chlorhexidine in reducing the bacterial infection of the root canals. Materials and Methods: The root canals of 55 single-rooted teeth were cleaned, shaped, and sterilized. All the teeth samples were inoculated with Enterococcus faecalis and incubated at 37°C for 2 weeks. Then, the teeth were divided into four groups. Group I (n=15): 100 ppm silver nanoparticles, Group II (n=15): 2.5 sodium hypochlorite, Group III (n=15): 2% chlorhexidine, IV (n=10): Normal saline as a contr

... Show More
Publication Date
Thu Jun 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Anti-Microbial Effect Of Different Time’sexposureofozonized Gas And Ozonized Water Onperiodontalpathogens (In Vitro Study)
...Show More Authors

Background: the oral cavity is consider to be an open ecosystem, with the balance between the microorganism’s entrance and the defenses of the host. The initiation of periodontitis has been associated with restricted kinds of anaerobic bacteria, such as Aggregatibacter actinomycetemcomitans (A.a) and Porphyromonas gingivalis (P.g) in plaque subgingivally. Ozone has a biological effects on bacteria due to oxidation of bio-molecules and its toxins. The aim is to determine and compare the antimicrobial effect of gaseous ozone and ozonized water on the growth of isolated anaerobic bacteria (A.a and P.g) when exposed to different time intervals. Materials and methods:This experiment is done byozone generator OLYMPIC- III(600mg/hr) to gene

... Show More
View Publication Preview PDF
Crossref (1)
Crossref