Preferred Language
Articles
/
jbcd-137
An in vitro evaluation of fit of the crowns fabricated by zirconium oxide-based ceramic CAD/CAM systems, before and after porcelain firing cycles and after glaze cycles
...Show More Authors

Background: The objective of this in vitro study was to evaluate the vertical marginal fit of crowns fabricated with ZrO2 CAD/CAM, before and after porcelain firing cycles and after glaze cycles. Materials and Methods: An acrylic resin model of a left maxillary first molar was prepared and duplicated to have Nickel-Chromium master die. Ten die stone dies were sent to the CAD/CAM (Amann Girrbach) for crowns fabrication. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) before (Time 0) and after porcelain firing cycles (Time 1) and after glaze cycles (Time 2) using a light microscope at a magnification of ×100. One way ANOVA LSD tests were performed to determine whether the mean and standard deviation of sub group Time 2. Results: The mean values of the ZrO2 CAD/CAM Time 0 were (6.77?m), Time 1(8.75?m) and Time 2(10.62 ?m). One way ANOVA test revealed highly statistical significance(P<0.01). LSD test results showed that there is highly significant difference between time (0) and time (2), while there is no any significant difference between time (0) and time (1), and between time (1) and time (2). Conclusions: Within the limitations of this study, it was concluded that the ZrO2 CAD/CAM demonstrated acceptable marginal fit; The porcelain firing and the glaze firing cycles affected the marginal gap

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Oct 17 2018
Journal Name
Iraqi Journal Of Laser
Thermal Effects of 940 nm Diode Laser on Dental Socket Blood after Teeth Extraction for Diabetic Patients
...Show More Authors

Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Says Rev Pharm
Healing of apical periodontitis after minimally invasive endodontics therapy using Er,Cr:YSGG laser: A prospective clinical study
...Show More Authors

Scopus (7)
Scopus
Publication Date
Mon Jan 01 2024
Journal Name
مجلة ميسان للدراسات الأكاديمية
Adhesion Of 3D Printed Acrylic Resin With Silicone Soft Liner After Sandblast Surface Treatment:, A Review Of Literature
...Show More Authors

View Publication
Crossref
Publication Date
Mon Jan 25 2021
Journal Name
Engineering And Technology Journal
Performance evaluation of Photovoltaic Panels by a Proposed Automated System Based on Microcontrollers
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Tue Dec 13 2022
Journal Name
Dental Hypotheses
Comparative Evaluation of Marginal Microleakage Between Bulk-Fill, Preheated Bulk-Fill, and Bulk-Fill Flowable Composite Resins Above and Below Cemento-Enamel Junction Using Micro-Computed Tomography: An In Vitro Study
...Show More Authors

Objective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil

... Show More
View Publication
Scopus (12)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Assessment of the Impact of Adhesive and Wires Types on the Tensile Bond Strength of Fixed Lingual Retainers Used in Orthodontics: An In Vitro Study
...Show More Authors

Introduction: We aimed to assess the impact of adhesive and wires types on the tensile bond strength of fixed lingual retainers. Methods: A total of 160 intact bovine teeth were collected, cleaned, stored in 25% sodium hypochlorite, and randomly assigned to two groups based on the adhesive type: a two-step adhesive and a one-step adhesive. Each group was further divided into four subgroups based on the type of lingual retainer wire, which included (A) 8-strand braided stainless steel wire, (B) three-strand titanium retainer wire, (C) stainless steel chain, and (D) fiber-reinforced retainer. A tensile bond strength test was conducted using a universal testing machine at a controlled speed of 10 mm/min. Result: The 8-strand braided stainles

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Oct 04 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Inhibition of bacterial growth around gutta percha cones by different antimicrobial solutions using antibiotic sensitivity test (An in vitro study)
...Show More Authors

Background: Decontamination of gutta percha cones was important factor for success of root canal treatment. The aim of the present in vitro study was to identify and to compare the antimicrobial effect of following disinfection solutions: 0.2% chlorhexidine gluconate, Iodine, tetracycline hydrochloride solution, EDTA & formocresol mixed with zinc oxide eugenol, on E faecalis, E coli and Candida albicans using sensitivity test Materials and Methods: Three types of microorganisms were isolated from infected root canals (E faecalis, E coli and Candida albicans) and cultured on Mueller Hinton agar petri-dishes. Disinfection of gutta percha cones done by immersion in six disinfection solutions (six groups), the groups are: distill water (used a

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Evaluating Filtration and Thermal Stability of Water-Based Mud Using Green Synthesized Zinc Oxide Nanoparticles
...Show More Authors

   Nanoparticles (NPs) have unique capabilities that make them an eye-opener opportunity for the upstream oil industry. Their nano-size allows them to flow within reservoir rocks without the fear of retention between micro-sized pores. Incorporating NPs with drilling and completion fluids has proved to be an effective additive that improves various properties such as mud rheology, filtration, thermal conductivity, and wellbore stability. However, the biodegradability of drilling fluid chemicals is becoming a global issue as the discharged wetted cuttings raise toxicity concerns and environmental hazards. Therefore, it is urged to utilize chemicals that tend to break down and susceptible to biodegradation. This research presents the pra

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Visible-Light-driven Photocatalytic Properties of Copper(I) Oxide (Cu2O) and Its Graphene-based Nanocomposites
...Show More Authors

In this study, an improved process was proposed for the synthesis of structure-controlled Cu2O nanoparticles, using a simplified wet chemical method at room temperature. A chemical solution route was established to synthesize Cu2O crystals with various sizes and morphologies. The structure, morphology, and optical properties of Cu2O nanoparticles were analyzed by X-ray diffraction, SEM (scanning electron microscope), and UV-Vis spectroscopy. By adjusting the aqueous mixture solutions of NaOH and NH2OH•HCl, the synthesis of Cu2O crystals with different morphology and size could be realized. Strangely, it was found that the change in the ratio of de-ionized water and NaOH aqueous solution led to the synthesis of Cu2O crystals of differen

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (20)
Scopus Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Journal Of Orthodontic Science
Antimicrobial behavior of nanocoated orthodontic micro-implants: An in vitro study
...Show More Authors
OBJECTIVE:

The need to overcome the failure of orthodontic micro-implants which might reach to 30% has led to the development of different methods, one of which is nanoparticle deposition.

AIM OF STUDY:

To evaluate the anti-microbial efficiency of TiO2 and ZnO nanoparticles (NP) when used as a coating for orthodontic micro-implants.

METHODS:

Thirty titanium alloy micro-implants were used in the presented study. They were divided into three

... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Crossref