Preferred Language
Articles
/
jbcd-131
Effect of surface treatments and thermocycling on shear bond strength of various artificial teeth with different denture base materials
...Show More Authors

Background: Separation and deboning of artificial teeth from denture bases present a major clinical and labortory problem which affect both the patient and the dentist. The optimal bond strength of artificial teeth with denture base reinforced with nanofillers and flexible denture bases and the effect of thermo cycling should be evaluated. This study was conducted to evaluate and compare the shear bond strength of artificial teeth (acrylic and porcelain) with denture bases reinforced by 5% Zirconium oxide nanofillers and flexible bases under the effect of different surface treatments and thermo cycling and comparing the results with conventional water bath cured denture bases. Material and methods: Two types of artificial teeth; acrylic and porcelain were used and prepared for this study. Five specimens of each tooth type were processed to each denture base materials after the application of different surface treatments; these teeth were bonded to heat polymerized, nano composite resin and flexible denture bases. Specimens were thermo cycled and tested for bond strength until fracture with an Instron universal testing machine. Data were analyzed with analysis of variance and student T-test. Photomicrographic examinations were used to identify adhesive and cohesive failures within debonded specimens. Results: The mean force required to fracture the specimens were obviously larger for nanocomposite specimens compared with the heat cured and flexible specimens. The most common failure was cohesive within the tooth or the denture base. With each base material, the artificial teeth which were treated with thinner exhibited highest shear bond strength. Thermocycling had deleterious effect on the flexible denture base specimens. In general, nanocomposite and heat cured groups failed cohesively within the artificial tooth. While the valplastic groups failed adhesively at the tooth denture base interface. Conclusions: Within the limitations of this study, the type of denture base materials and surface treatments of the tooth selected for use may influence the shear bond strength of the tooth to the base. Selection of more compatible combinations of base and artificial teeth may reduce the number of prosthesis fractures and resultant repairs. Key words: acrylic teeth, porcelain teeth, Nano composite denture base, thermo cycling, flexible denture, thinner,

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jul 17 2021
Journal Name
International Journal Of Research In Social Sciences And Humanities
Reconstruction of Female Identity Through Unattainable Beauty Standards in Zadie Smith's White Teeth
...Show More Authors

Reconstruction of female identity is one of the important issues in modern times. The majority of the females who descent from the countries of the third world confront lots of problems because of their race and gender. Black females or colored skin females because of the oppression of the white society upon them, try hard to cope with society in order to get some relief and feel that they are part of this cruel white society. One of the solutions for these black females is to reconstruct their identity by mimicry to the English beauty standards. Zadie Smith is a postcolonial author. She deals with third- world women and how they are treated in a minority and in a racist way. She strives to empower the subaltern black females who ha

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 01 2017
Journal Name
Journal Of Controlled Release
Surface engineering tumor cells with adjuvant-loaded particles for use as cancer vaccines
...Show More Authors

View Publication
Scopus (32)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Mon Nov 04 2019
Journal Name
Applied Physics Letters
Stability of organic permeable base transistors
...Show More Authors

Organic Permeable Base Transistors (OPBTs) reach a very high transit frequency and large on-state currents. However, for a later commercial application of this technology, a high operational stability is essential as well. Here, the stability of OPBTs during continuous cycling and during base bias stress is discussed. It is observed that the threshold voltage of these transistors shifts toward more positive base voltages if stressed by applying a constant potential to the base electrode for prolonged times. With the help of a 2D device simulation, it is proposed that the observed instabilities are due to charges that are trapped on top of an oxide layer formed around the base electrode. These charges are thermally released after rem

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Civil Engineering Journal
Experimental and Numerical Investigations of Composite Concrete–Steel Plate Shear Walls Subjected to Axial Load
...Show More Authors

This research is presented experimental and numerical investigations of composite concrete-steel plate shear walls under axial loads to predicate the effect of both concrete compressive strength and aspect ratio of the wall on the axial capacity, lateral displacement and axial shortening of the walls. The experimental program includes casting and testing two groups of walls with various aspect ratios. The first group with aspect ratio H/L=1.667 and the second group with aspect ratio H/L=2. Each group consists of three composite concrete -steel plate wall with three targets of cube compressive strength of values 39, 54.75 and 63.3 MPa. The tests result obtained that the increase in concrete compressive strength results in increasing

... Show More
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Structures
Behaviour and design of the ‘lockbolt’ demountable shear connector for sustainable steel-concrete composite structures
...Show More Authors

In order to promote sustainable steel-concrete composite structures, special shear connectors that can facilitate deconstruction are needed. A lockbolt demountable shear connector (LB-DSC), including a grout-filled steel tube embedded in the concrete slab and fastened to a geometrically compatible partial-thread bolt, which is bolted on the steel section's top flange of a composite beam, was proposed. The main drawback of previous similar demountable bolts is the sudden slip of the bolt inside its hole. This bolt has a locked conical seat lug that is secured inside a predrilled compatible counter-sunk hole in the steel section's flange to provide a non-slip bolt-flange connection. Deconstruction is achieved by demounting the tube from the t

... Show More
View Publication Preview PDF
Scopus (32)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Fri Jan 11 2019
Journal Name
Iraqi Journal Of Physics
Effect of water absorption on some mechanical and physical properties of epoxy/polyurethane blend reinforced with nano silica powder
...Show More Authors

The aim of this work is to evaluate some mechanical and physical
properties (i.e. the impact strength, hardness, flexural strength,
thermal conductivity and diffusion coefficient) of
(epoxy/polyurethane) blend reinforced with nano silica powder (2%
wt.). Hand lay-up technique was used to manufacture the composite
and a magnetic stirrer for blending the components. Results showed
that water had affected the bending flexural strength and hardness,
while impact strength increased and thermal conductivity decreased.
In addition to the above mentioned tests, the diffusion coefficient
was calculated using Fick’s 2nd law.

View Publication
Crossref (2)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Effect of varicocelectomy on sperm parameters, oxidative stress and Chromatin maturity in seminal fluid of infertile patients with varicocele
...Show More Authors

This study aimed to determine the effect of varicocelectomy on sperm parameters, oxidant- antioxidant status and chromatin maturity percent. The current study has been conducted on 154 infertile patients complaining from varicocele and varicocelomized men in addition to 25 fertile men as control. The results revealed significant decrease (P<0.05) in sperm concentration, progressive motile sperm percent, normal sperm morphology percent, GSH, SOD1, CAT levels and chromatin maturity percent and significant increase (P<0.05) in MDA and ROS concentrations in infertile patients with varicocele when compared to fertile men. The results revealed improvement (P<0.05) of sperm parameters quality, GSH, SOD1, CAT, MDA, ROS concentration and chromatin m

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 31 2019
Journal Name
Journal Of Pure And Applied Microbiology
Determination of Level of 25-Hydroxy Vitamin D3 in Patients with Multiple Sclerosis and Its Effect on Disease Activity
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Mar 03 2019
Journal Name
Muthanna Journal Of Agriculture Science
EFFECT OF FOLIAR SPRAY WITH SEAWEEDS EXTRACT ON YIELD AND QUALTY FOUR CLASS OF BROAD BEAN (Vicia faba L.)
...Show More Authors

A field experiment was carried out in one of the agricultural fields in Thi Qar governorate in Nasiriyah during the winter season 2017-2018 The aim was to investigate the effect of foliar application of seaweed extract on yield and quality of four varieties of broad bean .The design of field experiment was (RCBD) in factorial experiments with three replications in two factors. .The first factor included four broad bean cultivars (Luz de otono – Grano Violtto -local - Aquadols. ( The second factor included four sprayed extracts of the seaweed extract (1, 2, 3 and 4 g L -1) In addition to the comparison treatment in which the plants were sprayed with distilled water only. . The plants of the broad bean that were sprayed with seaweed extract

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal
Surface analysis of the PEKK coating on the cp ti implant using laser technique
...Show More Authors

Objective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an

... Show More
Preview PDF
Scopus (7)
Scopus