Preferred Language
Articles
/
jbcd-1161
Salivary Oxidative Stress Markers in Relation to Vascular Disease Risk of Type Two Diabetes Mellitus
...Show More Authors

Background: Cardiovascular disease (CVD) is an important complication of type 2 diabetes mellitus (T2DM). Oxidative stress plays a major role in the development of CVD. Saliva has a diagnostic properties aiding in the detection of systemic diseases. This study aimed to assess the association between salivary oxidative stress markers and the risk of vascular disease (VD) in T2DM patients. Materials and Methods: One hundred T2DM patients and fifty apparently healthy males were enrolled in this study. Saliva sample was collected for assessment of oxidative stress markers including: lipid peroxidation plasma thiobarbituric acid-reactive substances (TBARS), uric acid (UA) and total antioxidant capacity (TAC) levels. Arterial stiffness index (ASI) was used for the assessment of VD risk. Results: According to ASI, T2DM patients were categorized into two groups: Group A: T2DM patients without VD risk. Group B: T2DM patients with VD risk. The mean values of TBARS and UA of group B showed a statistically highly significant elevation compared to group A and controls (P<0.01). The mean value of TAC of group B showed a statistically highly significant decrease when compared to group A and controls (P<0.01). Conclusion: The increase in salivary TBARS and UA levels and the decrease in the TAC level can be used as an indicator for the increase of risk for VD in T2DM patients.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Ieee Transactions On Robotics
Lidar-Level Localization With Radar? The CFEAR Approach to Accurate, Fast, and Robust Large-Scale Radar Odometry in Diverse Environments
...Show More Authors

View Publication
Scopus (39)
Crossref (37)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Reducing False Notification in Identifying Malicious Application Programming Interface(API) to Detect Malwares Using Artificial Neural Network with Discriminant Analysis
...Show More Authors

Publication Date
Sat Dec 11 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Difference in Contributing Factors and Costs Associated with Outpatient Refusal to Accept Cardiovascular Medications or Analgesics During Dispensing Process.
...Show More Authors

Background: Study looking into cardiovascular disorders (CVD) medicines or analgesics cost-saving activities during dispensing process is lacking.

Aim: To determine differences in factors and costs associated with refused CVD medicines or analgesics during dispensing process

Method: This study was approved by Medical Research and Ethics Committee (MREC) (Registration number: NMRR-20-177-53153(IIR)). Participants receiving CVD medicines or analgesics during dispensing process were recruited via convenience sampling technique between February and March 2020 at the Specialist Pharmacy Department of Jerantut Hospital, Malaysia. Refusal to medications and its reasons were asked based on the questionnaire developed by the resea

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Oct 14 2025
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Illness Perceptions and Response to Treatment with Romiplostim in Iraqi Patients with Refractory Immune Thrombocytopenia Purpura: A Cross-Sectional Study
...Show More Authors

Background: Immune thrombocytopenia is an immune-related disorder that causes an impairment in platelet production and stimulates platelet destruction, causing variable bleeding symptoms. Objective: This study focuses on refractory immune thrombocytopenic purpura patients on romiplostim treatment and their level of illness perception related to treatment response. Method: A cross-sectional study was conducted from May 1st, 2025, to August 1st, 2025. Brief Illness Perception Questionnaires were administered to 84 patients with ITP to collect the data. The study took place at the Hematology and Bone Marrow Transplant Center, Medical City, Baghdad, Iraq. Results: The romiplostim response rate is 21 (25.0%), while the partial response rate is 4

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Comparing Bayesian methods to estimate the failure probability for electronic systems in case the life time data are not available
...Show More Authors

In this research, we find the Bayesian formulas and the estimation of Bayesian expectation for product system of Atlas Company.  The units of the system have been examined by helping the technical staff at the company and by providing a real data the company which manufacturer the system.  This real data include the failed units for each drawn sample, which represents the total number of the manufacturer units by the company system.  We calculate the range for each estimator by using the Maximum Likelihood estimator.  We obtain that the expectation-Bayesian estimation is better than the Bayesian estimator of the different partially samples which were drawn from the product system after  it checked by the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Medicine And Life
Antimicrobial photodynamic therapy using a low-power 650 nm laser to inhibit oral Candida albicans activity: an in vitro study
...Show More Authors

Scopus
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Agricultural And Statistical Sciences
USE OF MODIFIED MAXIMUM LIKELIHOOD METHOD TO ESTIMATE PARAMETERS OF THE MULTIPLE LINEAR REGRESSION MODEL
...Show More Authors

Scopus
Publication Date
Mon Mar 01 2021
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study of the Influence of Nanoparticles Additive to Diesel Fuel on the Emission Characteristics
...Show More Authors

The present experimental work is conducted to examine the influence of adding Alumina (Al2O3) nanoparticles and Titanium oxide (TiO2) nanoparticles each alone to diesel fuel on the characteristic of the emissions. The size of both Alumina and Titanium oxide nanoparticles which have been added to diesel fuel to obtain nano-fuel is about 20 nm and 25 nm respectively. Three doses of (Al2O3) and (TiO2) were prepared (25, 50, and 100) ppm. The nanoparticles mixed with gas oil fuel by mechanical homogenous (manual electrical mixer) and ultrasonic processor. The study reveals that the adding of Aluminum oxide (Al2O3) and Titanium oxide (TiO2) to g

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Use of Ascetic Fluid Cholesterol as a Marker to Differentiate between Types of Ascetic Fluid
...Show More Authors

Background:- Cholesterol is high in ascetic fluid due
to malignancy and other causes of exudates.
Objective:-To use cholesterol as a marker to
differentiate between exudative and transudative
ascetic fluid and to compare that with other routine
parameters.
Methods:-Twenty eight patients were included in this
study 17 females with mean age of 41.9 years, 11
males with mean age of 48.2 years. The patients were
divided in group I suspected transudate, and group II
suspected exudate according to history and clinical
examination.
Ascetic fluid samples were sent for total protein,
albumin, and cholesterol measurement blood samples
were sent for serum protein and albumin measurement.
Results:-In this

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 30 2020
Journal Name
Journal Of Economics And Administrative Sciences
Possibility of electronic data interchange to simplify work procedures (Case Study of Hilla Municipality Directorate)
...Show More Authors

Purpose: to demonstrate the possibility of moving to electronic data exchange dimensions (regulatory requirements, technical requirements, human requirements, senior management support) to simplify the work procedures dimensions (modern procedures, clarity of procedures, short procedures, availability of information and means required. The simplicity of the models used because of its importance to keep abreast of recent developments in the service of municipal works through the application of electronic data interchange, which simplifies procedures and out of the routine in the performance of the work of municipal departments has developed. It was applied to Municipality (Hilla) so that the transformation

... Show More
View Publication Preview PDF
Crossref