Background: Elastomeric chains are one of the most commonly used force delivery systems. They have the ability to exert a continuous force, convenience of use, compatibility to oral environment and cost effectiveness but one of the inherited disadvantages is force degradation. Materials and methods: This in vitro study was designed to evaluate the effect of alcohol presence in mouthwashes on force decay of different configurations of clear elastomeric chains from (Ortho Technology company) which are: closed , short and long under the effect of time at (Initial, 1, 2, 3 and 4 weeks) intervals with exposure to different chemical solutions. A total (540) modules of elastomeric chains of three different types (long, short and closed) transparent in color, with an initial length (19mm) and about 50% extension (29mm) were used for the study. These elastomeric chains divided in to four groups and exposed to different chemical solutions (Listerine Original alcoholic mouthwash, Listerine Zero alcohol mouth wash, Ethanol 26.9%, distilled water) twice daily for 60 seconds according to manufacturer instructions to measure the amount of force degradation in different time intervals. These elastomeric chains were incubated in covered glass containers at 37C˚ for the entire testing period. Results: Statistical analysis showed that there was a highly significant difference in the mean percentage of force decay (P≤ 0.001). For all chemical solutions the highest percentage of force decay occurs in Listerine Original Alcoholic mouth wash. Also in all chemical solutions closed elastomeric chains has the least percentage of force decay. While closed configuration have the highest percentage of force decay. Conclusion: We can conclude that alcoholic mouth wash(Listerine Original) causes increase force degradation of all types of elastomeric chains while alcohol free mouth wash (Listerine Zero) causes less force degradation of all types of elastomeric chains. Also closed configuration elastomeric chains have the least percentage of force decay than other configurations.
The influence of Diethyl phthalate (DEP) on the optical characteristics of polystyrene solutions in the range between 200 to 400 nm at solvents of different polarities; chloroform, cyclohexane, dichloromethane, and tetrahydrofuran have been recorded. The experimental results showed that the behavior of the photophysical processes of polymer solutions depends on the nature of its environment. The intensity of the absorption and fluorescence spectra depends on the interactions between solvent-solute molecules. The experimental results indicate that the maximum most absorbance bands occur around 262 nm, which depends on the concentration of the quencher. The results did not determine any change in the positions of the most absorption bands.
... Show MoreA sensitive, accurate, and affordable colorimetric method was developed for assaying prednisolone (PRZ) in various medicinal forms. The procedure involves the oxidation of PRZ by ferric ions, followed by complexation of the resulting ferrous ions with ferricyanide to produce a greenish-blue product. Common complexation conditions were thoroughly investigated. The mole ratio of FeCl₃·6H₂O to K₃Fe(CN)₆ was 8:1. The proposed mechanism of complexation was suggested and considered. Various parameters were optimized, including the reduction of the colorimetric reaction temperature to 50°C and the duration of heating and analysis to 20-30 minutes. The calibration curve was linear over the range of 1-60 µg/mL. The limit of detection (LOD
... Show MoreIn vitro antifungal susceptibility test of itraconazole was carried out against 38 isolates from nails, skin, oral cavity, vagina and wounds, This study was done in Ramadi Teaching Hospital in period from January to August 2010. According to the National Committee for Clinical Laboratory Standard (NCCLS ) M 27- A by using the broth dilution method. Inoculum size was 1-5X103 CFU/ ml, while final concentrations of itraconazole ranged from 0.025 – 6.4 μg / ml by using RPMI – 1640 broth media and the fungus was incubated at 35 oC. No resistant stain was recorded. MIC ranged from 0.05 – 6.4 μg / ml and the Mean ± SEM was 0.89 ± 0.28. MIC for nail isolates was 0.05 –
... Show MoreIn this study the rate of infection in acute and chronic Toxoplasma gondii parasite that causes toxoplasmosis was determined. This study was Included 120 blood samples that collected from pregnant women revisions to some clinics and laboratories in Baghdad civil as well as 10 blood samples from non-infected women as a control group. All blood samples were collected in the first three months of the pregnancy period for detection toxoplasmosis by using serological tests of test kit ( Toxo , IgG.,Toxo , IgM ). To detect antibodies specialized type of IgG &IgM in acute and the chronic infection by Electro Clia manner using a Roche Cobas e411. The results showed that the total infection rate was (55.83)%, the rate of infection in acu
... Show MoreGymnastics is one of the most interesting games in terms of organizing various world championships and tournaments. Their basic skills and their technical development, especially those with high difficulty levels that rely on basic and complex skills, are the basic skills of gymnastics are the main pillar to be developed and therefore high-difficulty skills will not depend on basic skills, which should reach the stage of the automatic mechanism. Retention) in order to move on to training and developing another skill for the difficulty of movements as well as the smooth flow of performance, ie the degrees of difficulty of each skill specific to your gym and The researcher used the experimental method and The research community determin
... Show MoreTwo different polyvinyl alcohol/polyvinyl chloride (PVA/PVC) hollow fiber composite nanofiltration membranes were prepared after PVC hollow fiber membranes were coated using dip-coating method with PVA aqueous solution, which was composed of PVA, fatty alcohol polyoxyethylene ether (AEO9), and water [PVA/AEO9/water (4:0.5:95.5) wt%]. Effect of two different PVC hollow fiber immersion times in coating solution were studied. Cross-section, internal and external surfaces of the PVC hollow fibers and PVA/PVC composite nanofiltration membranes structures were characterized by scanning electron microscopy (SEM), pure water permeation flux and solutes rejection. It was found that, the coating layer thickness on the outer surface of the 19 wt% P
... Show MoreGod Almighty put in his great book secrets that do not end, and wonders that do not expire, for he is the one from which the scholars are not satisfied, and he does not create due to the multitude of response, and it is the comprehensive and inhibitory book that God conceals to the worlds, and he challenged the two heavyweights to come up with something like it.
At all times, issues arise in the Noble Qur’an that fit the needs of the people of that time and their culture, for it is an eternal book, characterized by the ability to give, extend and respond to addressing the problems of the age and its variables, when the Arabs had little luck at the time of the message’s descent from the scientific culture, and their proficienc
... Show MoreThe Video effect on Youths Value
In the present work experiments were conducted to study the effect of solid loading (1,5 and 9 vol.%) on the enhancement of carbon dioxide absorption in bubble column at various volumetric gas flow rate (0.75, 1 and 1.5 m3/h) and absorbent concentration (caustic soda)( 0.1,0.5 and 1 M ). Activated carbon and alumina oxide (Al2O3) are used as solid particles. The Danckwerts method was used to calculate interfacial area and individual mass transfer coefficients during absorption of carbon dioxide in a bubble column. The results show that the absorption rate was increased with increasing volumetric gas flow rate, caustic soda concentration and solid loading. Mass transfer coefficient and interfac
... Show MoreExperiments were conducted to study axial liquid dispersion coefficient in slurry bubble column of 0.15 m inside diameter and 1.6 m height using perforated plate gas distributor of 54 holes of a size equal to 1 mm diameter and with a 0.24 free area of holes to the cross sectional area of the column. The three phase system consists of air, water and PVC used as the solid phase. The effect of solid loading (0, 30 and 60 kg/m3) and solid diameter (0.7, 1.5 and 3 mm) on the axial liquid dispersion coefficient at different axial location (25, 50 and 75 cm) and superficial gas velocity covered homogeneous-heterogeneous flow regime (1-10 cm/s) were studied in the present work. The results show that the axial liquid dispersion coeffic
... Show More