Background: Bone density is a major factor that affect mini implant primarily stability; no Iraqi studies have evaluated bone density related to mini-implant placement for orthodontic anchorage at age 13 -15 years. The present research aims to evaluate gender, side and site differences in the bone density at various orthodontic implant sites for the maxillary alveolar bone. Materials and methods: Twenty nine individuals (16 males and 13 females) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 21 points (9 points for each side and 3 points between the right and left central incisors) . Results: The results obtained showed that there are no significant differences in bone density between males and females and between the left and right sides were found. There was no significant differences in bone density between the maxillary buccal cortical bone and the palatal cortical bone were generally except that at lateral incisor and canine point where the palatal side had higher bone density than buccal side. The mean bone density of the cancellous bone in the anterior part was higher than that in the posterior of the maxilla. Conclusions: When orthodontic, mini implant are indicated, no gender and side difference affect the success rate regarding bone density.
Simple, sensitive and economical spectrophotometric methods have been developed for the determination of cefixime in pure form. This method is based on the reaction of cefixime as n-electron donor with chloranil to give highly colored complex in ethanol which is absorb maximally at 550 nm. Beer's law is obeyed in the concentration ranges 5-250 µg ml-1 with high apparent molar absorptivities of 1.52×103 L.mole-1. cm-1.
MB Mahmood, BN Dhannoon
ِabstract:In this research we prepared nanofibers by electrospinning from poly (Vinyl Alcohol) /TiO2. The spectrum of the solution (Emission) was studied and found to be at 772 nm, several process parameters were such as concentration of TiO2 , and the effect of distance from nozzle tip to the grounded collector (gap distance). The result of the lower concentration of, the smaller the diameter of nanofiber is. Increasing the gap distance will affect nanofibers diameter.
MR Younus, Al-A'DAB, 2011
A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.
... Show MoreNew technologies have risen into popularity causing the Liquid membrane techniques to evolve over other separation techniques due to its high selectivity and recovery, increased fluxes, and reduced investment and operating cost. This work focuses on extracting Methylene Blue (MB), a cationic dye using a simple BLM separation technique from its aqueous phase. It combines extraction and stripping in a single unit operation. The feed phase was an aqueous solution of MB, the solvent chosen was soybean oil for the liquid/organic membrane phase, and tri-octyl amine acted as a carrier. The strip phase was a hydrochloric acid solution for this study. A two-phase equilibrium study was done to choose the correct solvent, carrier,
... Show More