Preferred Language
Articles
/
jbcd-1152
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Marginal leakage of amalgam and modern composite materials related to restorative techniques in class II cavity (Comparative study)

Background: Restoration of the gingival margin of Class II cavities with composite resin continues to be problematic, especially where no enamel exists for bonding to the gingival margin. The aim of study is to evaluate the marginal leakage at enamel and cementum margin of class II MOD cavities using amalgam restoration and modern composite restorations Filtek™ P90, Filtek™ Z250 XT (Nano Hybrid Universal Restorative) and SDR bulk fill with different restoratives techniques. Materials and method: Eighty sound maxillary first premolar teeth were collected and divided into two main groups, enamel group and cementum group (40 teeth) for each group. The enamel group was prepared with standardized Class II MOD cavity with gingival margin (1 m

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 02 2016
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Comparative study between Harmonic FOCUSTM to clamp and tie technique for total thyroidectomy

Background: Thyroid surgery has undergone many changes during the past 2 decades, including the introduction of new surgical techniques such as endoscopic or video-assisted approaches, anesthesia care, intraoperative nerve monitoring and new hemostatic tools
Objectives: to assess the efficacy and safety of Harmonic Focus shears in total thyroidectomy compared with conventional surgical technique.
Patients and methods: prospective study conducted from October 2011 till January 2016, two handers and nine patients with benign and malignant thyroid diseases, scheduled for total thyroidectomy in a governor and private hospitals were enrolled randomly into 2 groups, group A consists of 105 patient who undergone a total thyroidectomy usin

... Show More
Crossref
View Publication Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Augmentation of the localized bony defects with synthetic bone substitute in simultaneous dental implant surgery(Clinical study)

Background: Simultaneous and staged guided bone regeneration (GBR) is one of the several surgical techniques that have been developed in the past two decades to regenerate bone and thus to allow implant placement in compromised sites (fenestration and dehiscence). It is a surgical procedure that consists of the placement of a cell-occlusive physical barrier between the connective tissue and the alveolar bone defect. The treatment concept advocates that regeneration of osseous defects is predictably attainable via the application of occlusive membranes, which mechanically exclude non-osteogenic cell populations from the surrounding soft tissues, thereby allowing osteogenic cell populations originating from the parent bone to inhabi

... Show More
View Publication Preview PDF
Publication Date
Sun May 10 2015
Journal Name
Al-academy
Performing processors of view between impressionism & superrealism (A comparative analysis): فريد خالد علوان

Addressed the problem of the research is marked: (Performing processors for the time between Impressionism and superrealism) the concept of time and how to submit artwork. The search came in four sections: general framework for research and identified the research problem and the need for him. With an indication of the importance of his presence. Then determine the research objectives of (detection processors performing to the concept of time in works of art in each of Impressionism and superrealism. And a comparison between them to reveal similarities and differences), followed by the establishment of boundaries Find three (objectivity, the temporal and spatial) were then determine the terms related to the title. Then provide the theore

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
University Of Baghdad
New Analytical Methods for Drugs Analysis A Comparative Study

Four different spectrophotometric methods are used in this study for the determination of Sulfamethoxazole and sulfanilamide drugs in pharmaceutical compounds, synthetic samples, and in their pure forms. The work comprises four chapters which are shown in the following: Chapter One: Includes a brief for Ultraviolet-Visible (UV-VIS) Absorption spectroscopy, antibacterial drugs and sulfonamides with some methods for their determination. The chapter lists two methods for optimization; univariate method and multivariate method. The later includes different types, two of these were mentioned; simplex method and design of experiment method. Chapter Two: Includes reaction of the two studied drugs with sodium nitrite and hydrochloric acid for diazo

... Show More
Preview PDF
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Comparative Analysis of Various Multicarrier Modulation Techniques for Different Multilevel Converters

The applications of Multilevel Converter (MLC) are increased because of the huge demand for clean power; especially these types of converters are compatible with the renewable energy sources. In addition, these new types of converters have the capability of high voltage and high power operation. A Nine-level converter in three modes of implementation; Diode Clamped-MLC (DC-MLC), Capacitor Clamped-MLC (CC-MLC), and the Modular Structured-MLC (MS-MLC) are analyzed and simulated in this paper. Various types of Multicarrier Modulation Techniques (MMTs) (Level shifted (LS), and Phase shifted (PS)) are used for operating the proposed Nine level - MLCs. Matlab/Simulink environment is used for the simulation, extracting, and ana

... Show More
Crossref (2)
Crossref
View Publication Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
A Comparative Study between Transcutaneous Bilirubinometry and Total Serum Bilirubin Measurement in Jaundiced Newborns

Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. 

Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice.

Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospi

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sun Oct 01 2023
Journal Name
Journal Of The Faculty Of Medicine Baghdad
A Comparative Study between Dusting and Fragmentation in Intracorporeal Laser Lithotripsy in Distal Ureteric Stone

Background: Ureteric stones commonly have an impact on the quality of life of the patient. There are many treatment choices for the condition, including medical treatment, extra-corporeal shock wave lithotripsy (ESWL), endoscopic intervention by ureteroscope (URS), or surgery (open or laparoscopic). Semi-rigid URS with laser lithotripsy is used to fragment ureteric stones, especially those in the distal ureter.

Objectives: To assess the efficacy and complications of the dusting versus the fragmentation method for lower ureteric stones using holmium laser lithotripsy by analyzing intra-operative and post-operative variables.

Patients and methods: One hundred and twenty patie

... Show More
Crossref
View Publication Preview PDF
Publication Date
Tue Nov 19 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Salivary cortisol among low birth weight 5 years old kindergarten children in relation to dental caries (comparative study)

Background: Birth weight is a powerful predictor of infant growth and survival. Evidence now shows that children born with low birth weight face an increased risk of chronic diseases and have many health problems including oral health. The aims of this study were to assess the salivary flow rate, viscosity, and salivary cortisol among low birth weight kindergarten children aged 5 years old in Hilla centre, in relation to dental caries and compares them with the normal birth weight children of the same age and gender. Materials and methods: The total sample involved 80 children (40 low birth weights and 40 normal birth weights) aged 5 years old. The diagnosis and recording of severity of dental caries was recorded through the application of

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Implant Primary Stability: A Comparison of the Surgeon’s Tactile Sense and Objective Measurements

Background: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou

... Show More
Crossref
View Publication Preview PDF