Preferred Language
Articles
/
jbcd-1152
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis
...Show More Authors

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 29 2024
Journal Name
Journal Of The College Of Basic Education
Detection Of Biofilm Formation By Beta- Lactam Resistance Klebsiella Pneumoniae Isolated From Clinical Specimens And Aquatic Samples
...Show More Authors

Preview PDF
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
Synthesizing, Characterizing and Studying the Biological Activity of Some New Schiff-Bases Derivatives Containing the Monosaccharide Moiety
...Show More Authors

A new series of ?-D-glucose as Schiff bases derivatives is synthesized and characterized with studying their bioactivity. Hydroxyl groups at C (1,2&5,6) sugar moiety are converted into acetal form through a reaction with dry acetone using phosphoric acid and anhydrous zinc chloride as catalysts producing 1,2:5,6-di-O-isopropyledine ?-D-glucofuranose(I). The five memberd ring acetal of C(5,6) is hydrolyzed with acetic acid (65%)and a reaction of the new product with sodium periodate is carried on to get an aldehyde moiety which is used to produce a new series of Schiff bases through reacting with different amino compounds such as 4-amino antipyrene . The suggested chemical structures of the prepared compounds are confirmed by using UV., FT

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Early detection of periodontitis among young adult cigarette smokers and non-smokers using cone beam computed tomography
...Show More Authors

Background: Periodontitis is an inflammatory disease that affects the supporting tissues of the teeth; Smoking is an important risk factor for periodontitis induces alveolar bone loss and cause an imbalance between bone resorption and bone deposition. The purpose of this study is to detect and compare the presence of incipient periodontitis among young smokers and non-smokers by measuring the distance between cement-enamel junction and alveolar crest (CEJ-Ac) using Cone Beam Computed Tomography (CBCT). Material and methods: The total sample composed of fifty two participants, thirty one smokers and twenty one non-smokers (age range 14-22 years). Periodontal parameters: plaque index (PLI), gingival index (GI) were recorded for all teeth exc

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 30 2021
Journal Name
Iraqi Journal For Electrical And Electronic Engineering
EEG Motor-Imagery BCI System Based on Maximum Overlap Discrete Wavelet Transform (MODWT) and Machine learning algorithm
...Show More Authors

The ability of the human brain to communicate with its environment has become a reality through the use of a Brain-Computer Interface (BCI)-based mechanism. Electroencephalography (EEG) has gained popularity as a non-invasive way of brain connection. Traditionally, the devices were used in clinical settings to detect various brain diseases. However, as technology advances, companies such as Emotiv and NeuroSky are developing low-cost, easily portable EEG-based consumer-grade devices that can be used in various application domains such as gaming, education. This article discusses the parts in which the EEG has been applied and how it has proven beneficial for those with severe motor disorders, rehabilitation, and as a form of communi

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
  Positional Accuracy Assessment for Updating Authoritative Geospatial Datasets Based on Open Source Data and Remotely Sensed Images
...Show More Authors

OpenStreetMap (OSM) represents the most common example of online volunteered mapping applications. Most of these platforms are open source spatial data collected by non-experts volunteers using different data collection methods. OSM project aims to provide a free digital map for all the world. The heterogeneity in data collection methods made OSM project databases accuracy is unreliable and must be dealt with caution for any engineering application. This study aims to assess the horizontal positional accuracy of three spatial data sources are OSM road network database, high-resolution Satellite Image (SI), and high-resolution Aerial Photo (AP) of Baghdad city with respect to an analogue formal road network dataset obtain

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Acidic and Energy Drinks on Surface Roughness of Three Types of Bulk Fill Composite Materials
...Show More Authors

ABSTRACT Background: This study aimed to study the effect of some acidic drinks (Vinegars and fresh Orange juice) and energy drinks (Red bull) on surface roughness of three types of bulkfill composite materials: Filtek posterior bulkfill (3M), Sonicfill (Kerr) and Filtek p60 (3M). Materials and Methods: Total number of 120 samples are prepared by using a mold of (12mm diameter and 3mm height), which were divided into three groups forty samples for each group: Group A: Filtek bulkfill posterior composite (3M), Group B: Sonicfill composite (Kerr), Group C: Filtek P60 (3 M) which then divided into four sub- groups (n=10) (1) samples were kept in distilled water as a control group (2) samples were immersed in Redbull (3) samples were immersed

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Sep 03 2024
Journal Name
African Journal Of Biomedical Research
Assessment of Solubility, Moisture Content, Water Absorption and Thickness of Bioplastic synthesized from Iraqi Amber Rice Husks
...Show More Authors

Publication Date
Fri Mar 01 2024
Journal Name
Baghdad Science Journal
First Transition Metal Complexes Salts of Diazonium Derived from Nitrogen Heterocyclic Compound, Synthesis, Characterization and Biological Activity
...Show More Authors

Metal complexes chrome(III), manganese(II), iron(III), cobalt(II), nickel(II), cupper(II) and zinc(II) with diazonium of 3-amino-2-chloropyridine of general formula [2-Cl-C5H3N≡N]n[MXm], where n=2 or 3 for divalent and trivalent metal, m= 4 or 6  were synthesized. The complexes have been characterized by flame atomic absorption, (C.H.N), molar conductance, magnetic susceptibility UV-vis spectra, infrared spectra,1H-NMR spectroscopy and thermo gravimetric analysis (TGA and DTA). The measurements showed that the divalent metal ion complexes (M2+) have (1:2) M:L ratio with tetrahedral geometry around metal ions while the trivalent metal ions (M3+) formed (1:3) m

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of LED Light on Depth of Cure and Microhardness of Three Types of Bulkfill Composite
...Show More Authors

Background: To evaluate the ISO depth of cure of bulkfill composites and depth of cure which determined by Vickers microhardness test. Materials and Methods: Bulkfill resin composite specimens (n=150) were prepared of three bulkfill composite materials (TetricEvo Ceram, Quixfil and SDR) and light cured by Flash max p3 for 3, 10, 20 seconds and by wood pecker for 10, 20 seconds respectively, a mold was filled with one of the three bulkfill composites and light cured. The specimens removed from the mold and scraped by plastic spatula and the remaining length (absolute length) was measured which represent the ISO depth of cure. After that the specimens were returned into the mold and a microhardness indentation device applied on the specimen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Studying and Modeling the Effect of Graphite Powder Mixing Electrical Discharge Machining on the Main Process Characteristics
...Show More Authors

Abstract

This paper concerned with study the effect of a graphite micro powder mixed in the kerosene dielectric fluid during powder mixing electric discharge machining (PMEDM) of high carbon high chromium AISI D2 steel. The type of electrode (copper and graphite), the pulse current and the pulse-on time and mixing powder in kerosene dielectric fluid are taken as the process main input parameters. The material removal rate MRR, the tool wear ratio TWR and the work piece surface roughness (SR) are taken as output parameters to measure the process performance. The experiments are planned using response surface methodology (RSM) design procedure. Empirical models are developed for MRR, TWR and SR, using the analysis

... Show More
View Publication Preview PDF