Preferred Language
Articles
/
jbcd-1152
A Comparative Study between Flapped and Flapless Surgical Techniques in Dental Implant Stability According to Resonance Frequency Analysis
...Show More Authors

Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Influence of 805 nm Diode Laser on Plasmid Content of Some Locally Isolated Escherichia coli and Proteus Mirabilis
...Show More Authors

This work aimed to investigate the effect of Diode laser 805 nm on plasmid DNA and RNA
contents of some Gram negative bacteria represented by Escherichia coli and Proteus mirabilis isolates
.Plasmid extraction was done using two methods (Salting out and CTAB method).Different powers and
pulse repetition rates for 805 nm Diode Laser were used to study this effect. Results revealed that the
plasmid profile of the two species were highly affected using (2, 3) W at different frequencies including
5and 10 kHz as compared with 1 kHz while plasmids were gradually disappeared at 1W, 10 kHz. In the
same time the shining of RNA was also decreased gradually then disappeared with increasing powers
especially at 2W and 10 kHz cau

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 08 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effect of Aqueous Leaves Extract of Coriandrum sativum on Histological Structure and Liver Function of Male Albino mice
...Show More Authors

Medicinal plants are used to treat various diseases although little is known about their toxicity. Coriandrum sativum is one of the most commonly plants that is used to treat several physiological disorders. Thus, this study was conducted to evaluate the effect of aqueous extract of C. sativum on the structure and function of liver in male albino mice. Thirty male mice were randomly divided into three groups: Group 1 untreated (control), Group 2 and 3 were administrated orally with the aqueous extract of the plant at dose 125 and 250 mg/kg. b. w. For 30 days. The effect of the extract on liver weights, biochemical parameters as well as histological study were assessed. There were no significant difference (P>0.05) observed in relative organ

... Show More
Preview PDF
Publication Date
Sun Jan 01 2006
Journal Name
Anbar Journal Of Agricultural Sciences 4 (1)‏
EFFECT OF GIBBERELLIN AND LIQUORICE EXTRACT ON FRUITS PHYSICALS CHARACTERISTICS OF DATE PALM Phoenix dactylifera L. ZAHDI CV.‏
...Show More Authors

Publication Date
Fri Jul 01 2022
Journal Name
Iop Conference Series: Earth And Environmental Science
Studying Some Technical Indicators of the Local Manufactured Machine and Its Effect on the Wheat Crop “Tamuz cultivar”
...Show More Authors
Abstract<p>The effect of compound machine on wheat "Tamuz cultivar" was studied based on some technical indicators which were tested under three practical speed (PS) of 2.015, 3.143, and 4.216 km.hr-1 and three tillage depth (TD) of 11, 13, and 15cm. The split-split plot arrangement in RCBD with three replications was used. The results showed that the PS of 2.015km.hr-1 was major best than other two speed in all studied conditions, physical properties (SBD and TSP), mechanical parameters (FD, (DP and LAS), and yield and growth parameters (PVI, BY and HI). The TD of 11cm was major effect to the other two levels TD of 13 and TD of 15cm in all studied conditions. All interactions were significant, </p> ... Show More
Scopus (7)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Agricultural Engineering
The Effect of Adjuvant Concentration on Changes of Spray Characteristics and Spraying Parameters for Selected Types of Nozzles
...Show More Authors
Abstract<p>The paper presents the results of the research on the influence of the adjuvant concentration on the size of the drops produced by the spray nozzles of agricultural sprayers. For the tests, adjuvant Normaton with the composition of total nitrogen, amide nitrogen (N-NH<sub>2</sub>) and phosphorus pentoxide (P<sub>2</sub>O<sub>5</sub>) was used. The adjuvant was added to the water taken from the municipal water supply system of the city of Lublin. The tests were carried out for three concentrations, i.e. 75%, 100%, and 125% of the adjuvant concentration recommended by the manufacturer, and water without the adjuvant. The surface tension of water with adjuva</p> ... Show More
View Publication
Scopus (3)
Scopus Crossref
Publication Date
Fri Oct 06 2023
Journal Name
Journal Of The Pakistan Medical Association
The role of Tumour Necrosis Factor Alpha (TNF-ALPHA) serum level and genetic polymorphisms with cutaneous leishmania infections
...Show More Authors

Objective: To assess the role of tumour necrosis factor alpha level and genotyping in susceptibility to leishmaniasis.Method: The case-control study was conducted from March to July 2021 at Baqubah Teaching Hospital, Diyala, Iraq,and comprised patients of cutaneous leishmaniasis in group A and healthy controls in group B. The serum level andsingle nucleotide polymorphisms of tumour necrosis factor-alpha rs41297589 and rs1800629 were compared betweenthe groups. Data was analysed using SPSS 28.Results: Of the 150 subjects, there were 75(50%) in group A; 39(52%) males and 36(48%) females with mean age23.91±13.14 years. The remaining 75(50%) subjects were in group B; 38(50.7%) males and 37(49.3%) females withmean age 22.84±4.35 years.

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Micro-Bubble Flotation for Removing Cadmium Ions from Aqueous Solution: Artificial Neural Network Modeling and Kinetic of Flotation
...Show More Authors

In this work, microbubble dispersed air flotation technique was applied for cadmium ions removal from wastewater aqueous solution. Experiments parameters such as pH (3, 4, 5, and 6), initial Cd(II) ions concentration (40, 80, and 120 mg/l)  contact time( 2, 5, 10 , 15, and 20min), and surfactant (10, 20and 40mg/l) were studied in order to optimize the best conditions .The experimental results indicate that microbubbles were quite effective in removing cadmium ions and the anionic surfactant SDS was found to be more efficient than cationic CTAB in flotation process. 92.3% maximum removal efficiency achieved through 15min at pH 5, SDS surfactant concentration 20mg/l, flow rate250 cm3/min and at 40mg/l Cd(II) ions initial co

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Dec 14 2022
Journal Name
Journal Of The College Of Languages (jcl)
Compound Sentences modification, functions and characteristics from an educational point of view: Umformungen- Funktion- Merkmale unter didaktischen Perspektiven
...Show More Authors
This research deals with compound sentences in the German language and how to transform them and transfer them into a main sentence, touching on their functions and characteristics. Actual to nominative, which is a unique feature of the German language, with some diverse examples taken from various sources.
This case is distinguished, like other grammatical cases
... Show More
View Publication Preview PDF
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Polyamide (Nylon 6) Micro-Particles Incorporation into RTV Maxillofacial Silicone Elastomer on Tear and Tensile Strength
...Show More Authors

Background: The longevity of any prosthesis depends on the materials from which it was fabricated, that is why, defects in the material properties may reduce the service life of prosthesis and necessitate its replacement. The aim of this study was to evaluate the effect of adding different concentrations of Polyamide-6 (Nylon-6) on the tear and tensile strength of A-2186 RTV silicone elastomer. Materials and Methods: 80 samples were fabricated by the addition of 0%, 1%, 3% and 5% by weight PA-6 micro-particles powder to A-2186 platinum RTV silicone elastomer. The study samples were divided into four (4) groups, each group containing 20 samples. One control group was prepared without PA-6 micro particles and three experimental groups were pr

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Fri Sep 04 2020
Journal Name
Al-kindy College Medical Journal
Association of Echocardiographic Epicardial Fat Thickness and Carotid Intima Media Thickness with the Severity of Coronary Artery Disease
...Show More Authors

Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coro

... Show More
View Publication Preview PDF
Crossref