Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.
This research describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc
The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar & reference divider in single chip. Therefore our system consists of a single chip contains (low phase noise PFD, charge pump, prescalar & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip
... Show MoreIN this work, a titanium dental implant was modified by electro-polymerized of 4-allyl-2-methoxyphenol (Eugenol) using direct current lower than 3.5 volt. The modification of titanium dental implant was achieved to improve its corrosion resistant. Fourier transform infrared spectroscopy (FTIR) was employed to confirm the electro-polymerization of Eugenol to Poly Eugenol (PE) on pure titanium. Deposition of PE on titanium was confirmed by X-ray diffraction and was characterized by thermogravimetric analysis (TGA). The surface morphology of polymeric film were examined through scanning electron microscopy (SEM). Coated titanium by (PE) revealed a good corrosion protection efficiency even at temperature ranged (293-323)K in artificial saliva.
... Show MoreConventional cooling systems are major energy consumers in hot climates, directly contributing to increased carbon emissions and placing a significant strain on Iraq's national electricity grid. This study aims to explore and evaluate clean and sustainable alternatives to conventional systems. The methodology is based on a comparative analysis of various cooling technologies, including mechanical, absorption, adsorption, drying, and hybrid systems, using key performance indicators such as the coefficient of performance (COP), energy consumption, carbon emissions, and system cooling capacity. The results show that innovative solar cooling technologies offer superior operational effi
This study presents a histological comparison of the esophagus between squirrels and mongooses, illustrating herbivorous and carnivorous dietary adaptations, respectively. Histological sections were examined from both species to compare the tunica mucosa, submucosa, muscularis, and adventitia. Esophageal samples were collected from adult specimens that were stained with hematoxylin and eosin (H&E) and Masson’s trichrome, then examined microscopically. Results revealed that squirrels exhibited a thick wall with non-keratinized epithelium and fully striated muscularis, reflecting a plant-based diet. In contrast, mongooses displayed regional variation in wall thickness and thinner mucosa in the upper third and a transition from s
... Show MoreWith their strategic and geographical positions, Japan and Iraq are one of the major
countries in the world, especially to the United States. Japan lies near the two American
Continents, separated only by the Pacific and it is only normal to have the interests of both
countries crossed and joined in the Far East region. This made the occupation of Japan an
inventible matter in the second half of the 20th century. Iraq, on the other hand, has strategic
position in the Middle East, being surrounded by many active countries like Turkey, Iran, and
Gulf countries, besides Iraq’s oil wealth which is needed by such industrial country like the
United States.
The increasing drinking water demand in many countries leads to an increase in the use of desalination plants, which are considered a great solution for water treatment processes. Reverse osmosis (RO) and electro-dialysis (ED) systems are the most popular membrane processes used to desalinate water at high salinity. Both systems work by separating the ionic contaminates and disposing of them as a brine solution, but ED uses electrical current as a driving force while RO uses osmotic pressure. A direct comparison of reverse osmosis and electro-dialysis systems is needed to highlight process development similarities and variances. This work aims to provide an overview of previous studies on reverse osmosis and electro-dial
... Show MoreThe analysis of Iraqi light oil (light naphtha) by capillary gas chromatography- mass spectrometry (GC-MS) was performed by the injection of whole naphtha sample without use of solvents. Qualitative analysis and the identification of the hydrocarbon constituents of light naphtha was performed and comparison had been done with American light oil (light naphtha). The obtained results showed a major difference between the two-light naphtha.
DBNRHM Sami, International Journal of Research in Social Sciences and Humanities, 2020