Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.
The objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc
... Show MoreDouble-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w
... Show MoreThe present study investigates the application of a combined electrocoagulation-electrooxidation (EC-EO) process for the treatment of wastewater generated from Al-Dewaniya petroleum refinery plant in Iraq. The EC-EO process was examined in terms of its ability to simultaneously produce coagulant and oxidant agents by using a parallel plate configuration system composed of stainless steel plates as cathode and pair of aluminum and graphite plates as anode at two different current concentrations (1.92A/l and 0.96A/l). The results showed that the best conditions for treatment of Al-Dewaniya petroleum refinery wastewater using the combined approach were current concentration of (0.96A/l), current density
In most manufacturing processes, and in spite of statistical control, several process capability indices refer to non conformance of the true mean (µc ) from the target mean ( µT ), and the variation is also high. In this paper, data have been analyzed and studied for a blow molded plastic product (Zahi Bottle) (ZB). WinQSB software was used to facilitate the statistical process control, and process capability analysis and some of capability indices. The relationship between different process capability indices and the true mean of the process were represented, and then with the standard deviation (σ ), of achievement of process capability value that can reduce the standard deviation value and improve production out of theoretical con
... Show MoreDeep learning has recently received a lot of attention as a feasible solution to a variety of artificial intelligence difficulties. Convolutional neural networks (CNNs) outperform other deep learning architectures in the application of object identification and recognition when compared to other machine learning methods. Speech recognition, pattern analysis, and image identification, all benefit from deep neural networks. When performing image operations on noisy images, such as fog removal or low light enhancement, image processing methods such as filtering or image enhancement are required. The study shows the effect of using Multi-scale deep learning Context Aggregation Network CAN on Bilateral Filtering Approximation (BFA) for d
... Show MoreAn electrocoagulation process has been used to eliminate the chemical oxygen demand (COD) from wastewaters discharged from the Al-Muthanna petroleum refinery plant. In this process, a circular aluminum bar was used as a sacrificial anode, and hallow cylinder made from stainless steel was used as a cathode in a tubular batch electrochemical Reactor. Impacts of the operating factors like current density (5-25mAcm-2), NaCl addition at concentrations (0-2g/l), and pH at values (3-11) on the COD removal efficiency were studied.
Results revealed that the increase in current density increases the COD removal efficiency, whereas an increase
In this work Laser wireless video communication system using intensity modualtion direct
detection IM/DD over a 1 km range between transmitter and receiver is experimentally investigated and
demonstrated. Beam expander and beam collimeter were implemented to collimete laser beam at the
transmitter and focus this beam at the receiver respectively. The results show that IM/DD communication
sysatem using laser diode is quite attractive for transmitting video signal. In this work signal to noise
ratio (S/N) higher than 20 dB is achieved in this work.
Background: Obesity is becoming the healthcare epidemic world wide.Obesity is associated with reduced life expectancy, increased morbidity and mortality, and greater healthcare costs.Bariatric surgery is the only effective treatment for morbid obesity and is gaining increasing popularity. There has been a steady rise in the numbers and types of bariatric operations done worldwide in recent years butnon of prove to be ideal .Animal studies and use of animal models are significant element in the evolution of medical knowledge and the use of animals as a model for bariatric surgery is of importance to study the mechanisms of these operationsa and also help to develop new technique in management of obesity.Objectives:Study of effects of slee
... Show MoreImproving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application