Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.
The molar ratio(x) of Li-Ni ferrites in the formula Li0.5-0.5xNixFe2.5-
0.5xO4 was varied in range 0.1-1.0 by hydrothermal process. The
XRD, SEM, and TEM tests were conducted to examine the samples
crystalline phase and to characterize the particles shapes and sizes.
The high purity spinel structure was obtained at med and high x
values. SEM and TEM images showed the existence of different
ferrite particles shapes like nanospheres and nanorods. The
maximum particle size is around (20nm). These size encourage
occurrence of super paramagnetic state. The reflection loss and
insertion loss as microwave losses of Li-Ni ferrite-epoxy composite
of 1mm thickness and mixing ratio 39.4 wt was investigated. The
mini
The aims of research is diagnose and indicate the role of fairness in the work of accounting, which is important in reducing the unacceptable practices to manage earnings by economic units, As well as the interpretation and indicate Ethical inside in the accounting and accountants in particular practices in the area of earnings management to reduce the negative effects of the practice and display the results mentioned acts according to what is supposed to be for the purposes of service users, Researchers have identified that one hypothesis, that "Fairness of accountants in of their work accounting lead to a reduction of earnings management practices". The results suggest that the accounting practices that lead to the manipu
... Show MoreSolid state blue laser source is a solid state laser include generation of IR laser light 1064 nm and companied with other wavelength 810 nm that invented from other active medium (Tm:ZBLAN) and non-linear crystal (CLBO) are used to generate fourth harmonic of the resultant wavelength 1874 nm that is blue laser light of 460nm. Several optical component have been designed by multilayer dielectric structure and anti reflection coating analysis. By using MATLAB soft ware, the simulation done and used the following non linear material (ZrO2, HfO2, MgO, SiO, Ta2O5 CaF2) and other linear material (ZnO, MgF2, GaAs, AlAs, BaF2, LiF, TiO2) as coating material. The result showed that as more quarter wave layers are added to the structure, the refl
... Show MoreBackground Over the past decade there has been a growing awareness of, and interest in, the trace element concentration differences between normal and diseased tissues. Significant changes in tissue concentrations of Zinc (Zn) and Copper (Cu) have been previously reported in inflammation and cancer of certain human tissues.
Aim:(1)To correlate between Zn and Cu concentrations and the histological picture of normal and certain inflamed human tissues, namely the gall bladder (GB) the vermiform appendix (VA), visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT). (2) to detect whether there is a difference in the above-mentioned parameters between VAT and SAT. (3) to obtain recordings for trace element levels in human tissu
It is no secret to everyone that the Arab individual suffers from poor self-awareness and political awareness, which made the state and the importance of its existence and preserving its institutions not among his interests, which made researchers wonder about the possibility of strengthening it and the extent of its impact on the future of building the contemporary Arab state, so the study attempted Addressing the issue of community awareness and its impact on building the state through a clear intellectual vision that blended what is social and political to define the concept of community awareness and highlight its importance and role as a basic pillar in shaping and building modern Arab countries. In the Arab world and ways to enhanc
... Show MoreIn this work, monitoring of monthly variation (from May 2016 to October 2016) in the concentration of the metals (Co, Zn, Cd, Pb, Ni and Fe) from Al-Diwaniya city of Iraq. Investigation about the pollution with these metals was achieved from five selected sites locate in study area by flame atomic absorption spectroscopy. The results showed a wide variation in the levels of heavy metals from site to site and from month to month. A total of 180 surface soil samples were analyzed to detecting the pollution with selected samples. The resultsshowed that the highest concentration with Ni was 6.290 mg kg-1 while the lowest concentration detected with Ni was 0.080 mg kg-1. The results of pollution index (enrichment factor, contamination factor, po
... Show MoreTo study the effect of iron overload due to continuous blood transfusions on peroxidation products, such as malondialdehyde (MDA) and peroxynitrite, with evaluation of some antioxidants like, glutathione (GSH), superoxide dismutase (SOD), vitamin A, vitamin C, vitamine E, Ceruloplasmin, uric acid and albumin in thalassemia patients. Forty patients with thalassemia major, aged 5 to 15 years, were carried out in Abn-Alatheer Teaching Hospital in Mosul city, during the period from October 2007 to April 2008. They were on Chelation therapy with desferÂrioxamine. They were divided into two groups, the first one without iron overload (90,97±12.92), and the second one with iron overload (157.75±7.57). All the patien
... Show MoreJohn Dewey is an American philosopher and psychologist. He is one of the primary figures of the philosophy of pragmatism. He is considered one of its founders and one of the leaders of the philosophy of pragmatism. He is one of the most famous figures of the modern education on the international level. His name is associated with the philosophy of education, because he delved in defining the purpose of education and went on talking about linking the theories with the reality without being subject to the existing system and the inherited traditions no matter how ancient they were. He is the godfather of progressive or gradual education, and he is one of the pioneers who established the experimental school in America in cooperation
... Show MoreThis research aims to develop transdermal patches of Ondansetron hydrochloride (OSH) with different types of polymers, ethyl cellulose and, polyvinyl pyrrolidone k30 in a ratio (3:0.5,3:1,3:2,2:1,1:1) with propylene glycol 20%w/w as a plasticizer. Prepared transdermal patches were evaluated for physical properties. The compatibility between the drug and excipients was studied by Differential scanning calorimetry (DSC), where there is no interaction between the drug and polymers. From the statistical study, there is a statistical difference between all the prepared formulations p<0.05. In-vitro Release study of transdermal patches was performed by using a paddle over the disc. The release profile of OSH follow
... Show More