Preferred Language
Articles
/
jbcd-1146
An Assessment of Sagittal Condylar Position of TMJ Dysfunction in Centric Occlusion by Using Cone Beam Computed Tomography
...Show More Authors

Background: Temporomandibular joint (TMJ) is a compound articulation formed from the articular surfaces of the temporal bone and the mandibular condyle.CBCT imaging of TMJ is that it allows accurate measurements of the volume and surface of the condyle. The aim of the study is to assess the sagittal position of mandibular condyle in patients with temporomandibulardysfunction using Cone Beam Computed Tomography in centric occlusion. Materials and Methods: CBCT images for all patients were obtained in an upright position using New Tom Giano CBCT with different field of view (11 x 8), (11 x 5), and (8 x 8) and exposure factors was changed accordingly using NNT version 5.1 software for sagittal reconstruction, anterior, superior and posterior joint spaces was measured. Results: There was a significant change in the anterior, posterior and superior joint spaces when compared to normal functioning TMJ. The sagittal position of the condyle in glenoid fossa could be affected by TMJ dysfunction and it would be positioned centrally but slightly inferior to the normal position according to the results of this study. There was no significant difference in the sagittal condylar position in glenoid fossa between sexes. There was significant difference in the value of anterior, posterior and superior TMJ spaces between right and left sides of the mandible in both normal cases and TMJD. Conclusion: Sagittal section of Temporomandibular joint revealed that TMJ dysfunction affects the joint spaces in sagittal plane. It means significant changes occur in the value of anterior, posterior and superior joint spaces when compared to normal functioning TMJ.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 13 2022
Journal Name
Dental Hypotheses
Comparative Evaluation of Marginal Microleakage Between Bulk-Fill, Preheated Bulk-Fill, and Bulk-Fill Flowable Composite Resins Above and Below Cemento-Enamel Junction Using Micro-Computed Tomography: An In Vitro Study
...Show More Authors

Objective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil

... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Feb 28 2019
Journal Name
Iraqi Journal Of Science
Assessment of Magnetite Polishing by Using Tigris River Stream Sediments in Baghdad: An Ore Microscopy Application
...Show More Authors

This aim of this study is to assess the Tigris River sediments and utilize them as a new abrasive for the preparation of polished surface of magnetite ore to be studied under reflected light ore microscope. Such polishing process was tested using 250, 125, 71, 45, 25 and 18μm grain sizes of the river sediments. For the completion of the polishing and to obtain a glossy perfect polished surface, the 7 and 2.5 μm sized standard diamond pastes were used. After each polishing stage, the reflectance and roughness of these surfaces were measured as an evaluation step for the polishing efficiency. The reflectance values (R%) of the magnetite surface were found to be reversely proportioned to the abrasive grain size; while the surface roughnes

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Comparison between Quantitative Computed Tomography and Dual-Energy X-Ray Absorptiometry in the Detection of Osteoporosis in Postmenopausal Women
...Show More Authors

Background: Osteoporosis is denoted by low bone mass and microarchitectural breakdown of bone tissue, directing to increased fracture risk and bone fragility. Fractures may lead to a decreased quality of life and increased medical costs. Thus, osteoporosis is widely considered a significant health concern.

Objective. This study aimed to compare quantitative computed tomography (QCT) and dual-energy X-Ray absorptiometry (DXA) to detect osteoporosis in postmenopausal women.

Subjects and Methods. We measured spinal volumetric bone mineral density (BMD) with QCT and areal spinal and hip BMD with DXA in 164 postmenopausal women. We calculated the osteo

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Computed tomography bone density in Hounsfield units at dental implant receiving sites in different regions of the jaw bone
...Show More Authors

Background: Determination of local bone mineral density (BMD) with cortical thickness and bone height may offer a comprehensive description of the bone the surgeon will encounter when he or she actually sets the implant. Quantitative computed tomography (CT) (i.e., quantitative interpretation of values derived from Hounsfield units with a suitable calibration procedure) is the modality of choice to determine BMD. The aim of the present clinical study is to determine the local bone density in dental implant recipient sites using computerized tomography. Material and method: The sample consisted of (72) Iraqi patients whom referred to Al-Kharkh General hospital, Spiral CT scan Department for bone quality and quantity assessment after one wee

... Show More
View Publication Preview PDF
Publication Date
Wed May 10 2023
Journal Name
Journal Of Engineering
Damage Detection and Assessment of Stiffness and Mass Matrices in Curved Simply Supported Beam Using Genetic Algorithm
...Show More Authors

In this study, a genetic algorithm (GA) is used to detect damage in curved beam model, stiffness as well as mass matrices of the curved beam elements is formulated using Hamilton's principle. Each node of the curved beam element possesses seven degrees of freedom including the warping degree of freedom. The curved beam element had been derived based on the Kang and Yoo’s thin-walled curved beam theory. The identification of damage is formulated as an optimization problem, binary and continuous genetic algorithms
(BGA, CGA) are used to detect and locate the damage using two objective functions (change in natural frequencies, Modal Assurance Criterion MAC). The results show the objective function based on change in natural frequency i

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Accuracy of spiral computed tomography in evaluation of maxillary sinus septa among dentate and edentulous Iraqi subjects (Comparative study)
...Show More Authors

Background: Presence of maxillary sinus septa has been known to be a complicating factor for sinus elevation procedure and implant placement in posterior maxilla. The maxillary sinuses septa are thin walls of cortical bone inside the sinus. They vary in number, location, and height. This study aimed to discover the accuracy of Spiral Computed Tomographic Scan in evaluation the maxillary sinus septa (prevalence, location, height) in subjects with dentate, partially edentulous and completely edentulous maxilla. Material and method: This study included (267) subjects ranged from (20-70 years), (132) male and (135) female divided into three groups, (97) fully dentate group, (102) partially edentulous group and (68) completely edentulous group w

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of Mandibular Third Molar Position by Using Space-Width Ratio Method
...Show More Authors

Background: The prediction of changes in the mandibular third molar position and eruption is an important clinical concern because third molar retention may be beneficial for orthodontic anchorage. The aims of this study were to assess the mandibular third molar position by using medical CT scan and lateral reconstructed radiograph and evaluate gender differences. Materials and Methods: The sample of present study consisted of 39 patients (18 males and 21 females) with age range 11-15 years who were attending at Al-Suwayra General Hospital/ the Computerized Tomography department. The distance from anterior edge of ramus to distal surface of permanent mandibular second molar and mesio-distal width of developing mandibular third molar were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 31 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Computed tomographic localization of infraorbital foramen position and correlation with the age and gender of Iraqi subjects
...Show More Authors

Background: The Infraorbital foramen is an anatomical structure with an important location in the maxilla, position of foramen in maxillofacial area is necessary in clinical situation requiring regional nerve blocks that are performed in children undergoing facial surgeries to avoid injury to corresponding nerve. The aim of study was to determine the position of the Infraorbital foramen and to correlate Infraorbital foramen position with age and gender using computed tomography. Subjects, Materials, and Methods: The sample consist of prospective study for 50 Iraqi subjects (21 male and 29 female) with age ranged from (5-17) years. The examination was performed on Multi – Slice Spiral Tomography scanner in Al-Karakh General Hospital. Using

... Show More
View Publication Preview PDF
Publication Date
Tue Oct 30 2018
Journal Name
Journal Of Engineering
Active Vibration Control of Cantilever Beam by Using Optimal LQR Controller
...Show More Authors

Many of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.  

In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
International Journal Of Computer Applications
Mobile Position Estimation based on Three Angles of Arrival using an Interpolative Neural Network
...Show More Authors

In this paper, the memorization capability of a multilayer interpolative neural network is exploited to estimate a mobile position based on three angles of arrival. The neural network is trained with ideal angles-position patterns distributed uniformly throughout the region. This approach is compared with two other analytical methods, the average-position method which relies on finding the average position of the vertices of the uncertainty triangular region and the optimal position method which relies on finding the nearest ideal angles-position pattern to the measured angles. Simulation results based on estimations of the mobile position of particles moving along a nonlinear path show that the interpolative neural network approach outperf

... Show More