Preferred Language
Articles
/
jbcd-1141
The Marginal Fitness of CAD/CAM All Ceramic Crowns Constructed by Two Typesof Direct Digitization Techniques (An In Vitro Study)
...Show More Authors

Background: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sampling technique). Materials and Methods: Sixteen sound upper first premolar teeth of comparable size were collected. Standardized preparation of all teeth samples were carried out to receive all ceramic crown restoration with deep chamfer finishing line (1mm), axial length (4mm) and convergence angle (6â—¦). The specimens divided in to two groups according to the type of digital impression technique: Group A, eight prepared teeth scanned directly by Bluecam camera; Group B, eight prepared teeth scanned directly by Omnicam camera. Then CAD/CAM all ceramic crowns constructed for each tooth sample. Marginal discrepancy was measured at Sixteen points per tooth using digital microscope at (120X) magnification. Results: Independent sample t-test was used to identify and localize the source of difference among the groups. It was found that there is statistically non- significant difference in the marginal gap mean values between (group A and group B). Conclusions: From the above result we can conclude that the two types of direct digitization techniques have the same accuracy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
An Approximate solution for two points oundary value problem corresponding to some optimal control
...Show More Authors

this paper presents a novel method for solving nonlinear optimal conrol problems of regular type via its equivalent two points boundary value problems using the non-classical

View Publication Preview PDF
Publication Date
Tue Sep 19 2017
Journal Name
Al-academy
Technology manufacturing Ghazi oven and sessile cost of production of ceramic
...Show More Authors

The ceramic work of the business that was stationed with the history of its evolution of man on earth, and this gives him a linking formula and the reality of life, including asking as inherited civilized . Operation creativity over several stages and developments have helped in the formation of human hands, including a reflection on productions are large and diverse.

To search for new horizons in ceramic art began to form new technologies outside the traditional frameworks ,devoted  technical and scientific expertise and access to an advanced stage in porcelain from technical and aesthetic point of view the field, shall be deemed to contemporary ceramic civilized idea of ​​Modernism from the ceramic work can in no way b

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Shear Bond Strength of Three Different Brackets Bonded on Zirconium Surfaces (In Vitro Study)
...Show More Authors

Background: With the increased in the demands of adult orthodontics, the challenge of direct bonding to non-enamel surface (zirconium) had been increased. The present study was carried out to compare the shear bond strength of three different brackets (stainless steel, sapphire and composite) bonded to zirconium surface and study the mode of bond failure. Materials and methods: The sample was comprised of 30 models (8mm *6mm*1.5mm) of full contour zirconium veneers. They were divided into three groups according to the brackets type; all samples were treated first by sandblast with aluminum oxide particle 50 µm then coated by z-prime plus primer. A central incisor bracket of each group was bonded to the prepared zirconium surface with lig

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Oct 06 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of zinc oxide nanoparticles on total salivary peroxidase activity of human saliva (In vitro study)
...Show More Authors

Background: The potential use of zinc oxide and other metal oxide nanoparticles in biomedical are gaining interest in the scientific and medical communities, largely due to the physical and chemical properties of these nanomaterials. The present work revealed the effect of zinc oxide nanoparticles (ZnONPs) on the total salivary peroxidase enzyme activity of human saliva in comparison to de-ionized water. Materials and methods: Forty eight unstimulated saliva samples were collected from dental students/University of Baghdad 18-22 years. Then measure the total salivary peroxidase activity first without any addition to human saliva as a control, second with dilution the saliva with de-ionized water, and third with zinc oxide nanoparticles in c

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 05 2010
Journal Name
Iraqi Journal Of Laser
Comparative Histological Study of Dentinopulpal Responses in Class I Cavity Treated by Er: YAG Laser and Conventional Cavity Preparations: An in Vivo Trial
...Show More Authors

The purpose of this study is to investigate the histopathological response of dentinopulpal
response of human teeth to the Er: YAG laser cavity preparation in comparison with the conventional
class I cavity preparation. Thirty five sound human upper and lower first premolar teeth which were
needed to be extracted for orthodontic purposes were used in the study. Regarding to the method of
cavity preparation, the teeth were grouped into three groups; Group1; Control group which consists of
seven sound teeth without cavity preparation, Group2; Conventional cavity preparation group and group
3; Er: YAG laser cavity preparation group. Each of Group2 and3 consists of fourteen teeth that is
subdivided into: A. 7teeth that e

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Fracture Toughness and Hardness studying for Polymer-Ceramic Composite
...Show More Authors

A particulate composite material was prepared by adding the Titanium dioxide (TiO2) with a particle size of (75-150) µm to Epoxy resin at weight percentage of (10%,20%,30%,40%,50%).The following some mechanical properties were studied,fracture toughness, hardness.casting preparation methods were used in this study includes preparing plate of matrix and composites. specimens were prepared according to ASTM for the Mechanical properties tests. After that Another samples were heat treated for three and six hour at 65C?. Fracture toughness (Kic) represent for stress intensity factor results were showed that the curve of three hours aging increases in fracture toughness (Kic) for composites but for six hours aging increases fracture tough

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Mar 31 2017
Journal Name
Journal Of Engineering
Rotating Ceramic Water Filter Discs System for Water Filtration
...Show More Authors

This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water.  The filtration system was designed with two rotating interfered modules of these filters.  Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs.    The average measured hy

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The economic feasibility of the accident insurance portfolio in the performance of insurance companies : an analytical study
...Show More Authors

The research aims to use performance indicators and financial criteria in evaluating the economic feasibility of the company's insurance portfolios. In addition to identifying the strengths and weaknesses in portfolio's performance to enhance the strengths and address the weaknesses. This is consistent with research problem that dealt with the performance indicators, economic feasibility of company's portfolios and contributing to their improvement, reducing the financial and insurance risks associated with company's business. The research’ sample is represented by the Iraqi Insurance Company as it is one of the oldest financial institutions operating in the insurance sector. It has identified (5) insurance portfolios (marine, engineer

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Physics And Chemistry Of Solids
Sensitization of TiO2 nanotube arrays photoelectrode via homogeneous distribution of CdSe nanoparticles by electrodeposition techniques
...Show More Authors

View Publication
Scopus (19)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of 2 different techniques in second stage implant surgery
...Show More Authors

Background: Dental implant is one of the most important options for teeth replacement. In two stage implant surgery, a few options could be used for uncovering implants, scalpel and laser are both considered as effective methods for this purpose. The Aim of the study: To compare soft tissue laser and scalpel for exposing implant in 2nd stage surgery in terms of the need for anesthesia, duration of procedure and pain level assessment at day 1 and day 7 post operatively using visual analogue scale . Materials and methods: Ten patients who received bilateral implants participated after healing period completed, gingival depth over each implant was recorded and then implant(s) were exposed by either scalpel or laser with determination for th

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref