Background: The present study was conducted to evaluate the effects of different bleaching methods on the shear bond strength of orthodontic Sapphire brackets bonded to human premolars teeth using light cured composite resin and to determine the predominant site of bond failure. Materials and Methods: Thirty freshly extracted human premolars were selected and randomly divided into three groups (10 per group). These groups are: control (unbleached) group, hydrogen peroxide group (HP) 37.5% ; which is the in- office bleaching method group, carbamide peroxide group (CP) 16%; which is the at- home bleaching method group. After bleaching process was performed, all the teeth stored in distilled water in a sealed container at room temperature for 24 hours before bonding was initiated, then orthodontic brackets were bonded with a light cure composite resin, stored in distilled water at room temperature for another 24 hours before debonding then the brackets de-bonded and tested for shear bond strength using an Instron universal testing machine. For adhesive remnant index (ARI) the enamel surface and bracket base of each tooth were inspected under magnifying lens (20X) of a stereomicroscope. Results and Conclusions: Non-statistically significant differences of shear bond strengths were found between the control group and the bleached groups, the dental bleaching in both methods did not affect the SBS of Sapphire brackets. The mode of failure was mostly between the adhesive and the enamel and the bond failure between the bracket base and the adhesive were also observed. Keywords: Shear bond strength, tooth bleaching agents, orthodontic brackets, dental bonding.
Ondansetron hydrochloride (ONH) is a very bitter, potent antiemetic drug used for the treatment and/or prophylaxis of chemotherapy or radiotherapy or postoperative induced emesis. The objective of this study is to formulate and evaluate of taste masked fast dissolving tablet (FDTs) of ONH to increase patient compliance.
ONH taste masked granules were prepared by solid dispersion technique using Eudragit E100 polymer as an inert carrier. Solvent evaporation and fusion melting methods were used for such preparation.
Completely taste masking with zero release of drug in phosphate buffer pH 6.8was obtained from granules prepared by solvent evaporation method using drug: polymer ratio of 1:2, from which four formulas pas
... Show MoreTo determine the evaluation of education program on women's knowledge regarding managing BSE. The present quasi- experimental study, Non-probability (purposive), sample consisting of (260) women who are employee, and students in both colleges (Nursing college, Medical and Health Techniques College). The sample consist of two groups, study group (130) including those in (Nursing college), and control group (130) in (Medical and Health Techniques College). A questionnaire was constructed which included, Demographic information, Reproductive information, Family history, Previous medical history, and information about women's knowledge toward management of breast self examination (BSE). Instrument validity and reliability was determined. Data w
... Show MoreA group of amine derivatives [4-aminobenzenesulfonamide derivatives, 2-aminopyridine and 2-aminothiazole] incorporated to α-carbon of diclofenac a well known non-steroidal anti-inflammatory drug (NSAID) to increase bulkiness were designed and synthesized for evaluation as a potential anti-inflammatory agents with expected COX-2 selectivity. In vivo acute anti-inflammatory activity of the selected final compounds (9, 12 and 13) was evaluated in rats using egg-white induced edema model of inflammation in a dose equivalent to (3 mg/Kg) of diclofenac sodium. All tested compounds produced a significant reduction in paw edema with respect to the effect of propylene glycol 50
... Show MoreThe proposed work is an attempt to investigate the stability of the nonlinear system by using a whale optimization algorithm as of one of the meta-heuristic optimization methods, and this investigation was conducted on a single inverted pendulum as a study model. The evaluation measures which were used in this article values of gain and sliding surface of the conventional sliding mode controller to illustrate the extent of the system`s stability. Furthermore, control action, the relationship between error and its derivative, desired, and actual position in addition to sliding response graphically showed the feasibility of the proposed solution. The attained results illustrated considerable improvement in the settling time and minimizing the
... Show MoreSewer system plays an essential task in urban cities by protecting public health and the environment. The operation, maintenance, and rehabilitation of this network have to be sustainable and scientifically. For this purpose, it is crucial to support operators, decision makers and municipalities with performance evaluation procedure that is based on operational factors. In this paper, serviceability and performance indicator (PI) principles are employed to propose methodology comprising two enhanced PI curves that can be used to evaluate the individual sewers depending on operational factors such as flowing velocity and wastewater level in the sewers. To test this methodology; a case study of al-Rusafa in Baghdad city is
... Show MoreBackground: Many structural or functional abnormalities can impair the production of thyroid hormones and cause hypothyroidism.Objectives: to identify the main etiological causes of hypothyroidism among patients visiting Specialized Center for Diabetes and Endocrinology.Methods: This study was conducted in the Specialized Center for Diabetes and Endocrinology on 217 patients with proved hypothyroidism, from 2006 to 2008. Every patient was tested with thyroid function tests, Ultrasound examination, thyroid autoantibodies, fine needle aspiration, radiology of skull, isotopes scan, also checking adrenal and gonadal function. Results: Out of these 217 patients 120 patients have thyroiditis 33 patients had been undergone thyroidectomy. 39 pat
... Show MoreObjective(s): This study aims to evaluate the hardness of two commercially available cold cured acrylic resin material
(Vertex and PAN) when polymerized at different temperature in comparison to those polymerized by conventional
methods in air at 23C ± 5C.
Methodology: Eighty specimens, forty from cold cured acrylic (Vertex Type) and forty from cold cured acrylic (PAN
type) were prepared, flasking and packing procedure were done according to manufacturer direction and divided
according to processing as follow: 20 specimens (10 from Vertex type and 10 from PAN type) were processed in air for
two hours at 23C ± 5C under press (bench curing) as a control, and 60 specimens (30 from Vertex type and 30 from
PAN type) wer
One of the main element in the network is the intersection which consider as the critical points because there are many conflict in this element. The capability and quality of operation of an intersection was assessed to provide a better understanding of the network's traffic efficiency. In Baghdad city, the capital of/Iraq the majority of the intersections are operated under the congestion status and with level of service F, therefore theses intersection are consider as high spot point of delay in the network of Baghdad city. In this study we selected Al-Ameria signalized intersection as a case study to represent the delay problem in the intersections in Baghdad. The intersection is located in the w
Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner re
... Show More