Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chlorhexidine(0.2%( (Parodontax) and toothpaste media (Sensodyne) for (1, 7 and 28) days intervals. Moreover, this study is intended to compare the corrosion pits for each type of archwires at these different media among all intervals. Materials and Methods: In this study, two hundred forty pieces of orthodontic wires of Teflon (Hubit) coated Stainless steel (120 pieces) and epoxy (Orthotechnology) coated Stainless steel (120 pieces), rectangular in cross section, size (0.019 x 0.025) inch and 15mm in length divided into four groups according to immersion media: (dry environment group, artificial saliva group, chlorhexidine group and toothpaste group). The atomic force microscope was used to measure the corrosion pits for all samples at dry and wet conditions and after different immersion periods. Results: Statistical analysis showed that there was a highly significant increase in the corrosion pits of Teflon coated stainless steel archwires (P ≤ 0.05) in wet environment at 28 days immersion period.The highest corrosion pits were found in the toothpaste medium for the two archwire types at 28 days immersion period. Conclusion: We can conclude that Epoxy coatedstainless steel archwires are indicated to be used above Teflon coated stainless steel archwires in terms of corrosion resistance. IfTeflon coated stainless steel archwires should to be used, they should be change in shorter periods than Epoxy coated stainless steel archwires type Key words: Esthetic coated archwire, corrosion, Teflon, Epoxy, wet environment, AFM.
Objectives: The study aims at finding the effectiveness of dietary habits on urolithiatic patients at Urinary Units
in Baghdad Teaching Hospitals.
Methodology: A quantitative descriptive study was conducted to identify the effectiveness of dietary habits on
(100) of urolithiatic patients in Urinary Units at Baghdad Teaching Hospitals starting from May 2011 to Sep.
2012.Data were collected through the use of constructed check list of the questionnaire format, which
consists of two parts: - The first part: is related to the patient's demographic variables ; the second part: is
constructed to serve the purpose of the study (effectiveness of the dietary habits). The total number of items
of the questionnaire is (69) item
The present study was undertaken to use individual terrestrial crustacean from Isopoda such as the species Porcellionides pruinosus (Brandt 1833) as environmental cleaner and that through the test of their abilities in decomposition of residues of some cellulosean wastes such as wood pieces which contain high ratio of urban wastes, and residue of Zea mays and particularly leaves as plant waste in agricultural fields and residue of Cynodon dactylon plants which compose the main wastes in most of gardens and parks. Experiments were conducted relatively in stable laboratory conditions to ensure environmental conditions similar to crustaceans' life. The results showed presence of good efficiency of these individuals in treating such wastes as
... Show MoreAphelenchus avenae was isolated from the wheat crown in Summel distract- Duhok, Kurdistan region-Iraq infected by a crown rot disease which is caused by Fusarium spp; wheat's crown culturing on Potato Dextrose Agar (PDA) and incubating at 25°C A. avenae was found associated with fungal culture which meant that fungal nematode was parasitic on crown rot fungi on wheat crown, this species was described for the first time in Iraq.
Fungal Nematode incubated with Fusarium graminearum, F. oxysporum and Verticillium dahliae reproduce in both solid and liquid media, best results of nematode reproduction were recorded on F. graminearum followed by F. oxy
... Show MoreBackground: Coronavirus, which causes respiratory illness, has been a public health issue in recent decades. Because the clinical symptoms of infection are not always specific, it is difficult to expose all suspects to qualitative testing in order to confirm or rule out infection as a test. Methods: According to the scientific studies and investigations, seventy-three results of scientific articles and research were obtained using PubMed, Medline, Research gate and Google Scholar. The research keywords used were COVID-19, coronavirus, blood parameters, and saliva. Results: This review provides a report on the changes in the blood and saliva tests of those who are infected with the COVID-19.COVID-19 is a systemic infection that has
... Show MoreSummary: The study focused on the role of the educational counselor in schools, as an integral part of the educational system that faces multiple challenges and difficulties. In this context, the counselor’s role becomes crucial in attempting to reduce or eliminate such difficulties, in addition to guiding students in an appropriate manner. Methodes: The study employed a descriptive field approach, using interviews and direct observation as tools to examine the actual role performed by school counselors. Results: The study concluded with several key findings, most notably the numerous challenges faced by counselors, including students’ negative behaviors, school dropouts, and the limited administrative support for counselors’ work. Fu
... Show MoreAn overall mathematical model for copper pipe corrosion in flowing water was derived based on mass transfer fundamentals where we introduced the effects of boundary layer velocity, bulk flow velocity and the surface oxide protective film on the corrosion rate. A set of experiments were conducted in a straight 10mm diameter copper pipe, flow of water include six velocities of maximum value 7.33m/sec at 200C and 350C. The good agreement between the calculated and experimental corrosion rate values were achieved , the agreement reached 92% .