Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chlorhexidine(0.2%( (Parodontax) and toothpaste media (Sensodyne) for (1, 7 and 28) days intervals. Moreover, this study is intended to compare the corrosion pits for each type of archwires at these different media among all intervals. Materials and Methods: In this study, two hundred forty pieces of orthodontic wires of Teflon (Hubit) coated Stainless steel (120 pieces) and epoxy (Orthotechnology) coated Stainless steel (120 pieces), rectangular in cross section, size (0.019 x 0.025) inch and 15mm in length divided into four groups according to immersion media: (dry environment group, artificial saliva group, chlorhexidine group and toothpaste group). The atomic force microscope was used to measure the corrosion pits for all samples at dry and wet conditions and after different immersion periods. Results: Statistical analysis showed that there was a highly significant increase in the corrosion pits of Teflon coated stainless steel archwires (P ≤ 0.05) in wet environment at 28 days immersion period.The highest corrosion pits were found in the toothpaste medium for the two archwire types at 28 days immersion period. Conclusion: We can conclude that Epoxy coatedstainless steel archwires are indicated to be used above Teflon coated stainless steel archwires in terms of corrosion resistance. IfTeflon coated stainless steel archwires should to be used, they should be change in shorter periods than Epoxy coated stainless steel archwires type Key words: Esthetic coated archwire, corrosion, Teflon, Epoxy, wet environment, AFM.
Fencing sport coaches seek fencers who have high velocity and work hard to develop it through training. The research problem lies on when measuring movement abilities through some tests. Manual measurement does not give reasonable impartiality of timing because there is a time-frame between the movement of the fencer and the speed of the movement of the human time setter. Therefore, the authors sought to design an electronic vest to evaluate movement abilities in foil fencers. The study design was experimental, with 12 Iranian foil fencers of the national team, who were divided into two equal groups of 6 fencers. Moreover, there were 12 students from Physical Education and Sport Sciences that worked on the scientific f
... Show MoreThe use of nanofluids in combination with magnetic fields has a wide range of applications in many fields, including cooling systems, microelectromechanical systems, medical systems, solar collectors, heat exchangers, and lubrication technologies. The magnetohydrodynamic (MHD) free convection in an inclined porous cylinder field with nanofluid was simulated numerically in this study. The heat was generated uniformly through the cylinder, and the horizontal walls were thermally insulated while the lateral wall remained at constant cold temperature. Vorticity transport and energy equations were used as the governing equations. A MATLAB code was developed to solve these equations after transforming them into algebraic equations using t
... Show MoreThe necessities of steganography methods for hiding secret message into images have been ascend. Thereby, this study is to generate a practical steganography procedure to hide text into image. This operation allows the user to provide the system with both text and cover image, and to find a resulting image that comprises the hidden text inside. The suggested technique is to hide a text inside the header formats of a digital image. Least Significant Bit (LSB) method to hide the message or text, in order to keep the features and characteristics of the original image are used. A new method is applied via using the whole image (header formats) to hide the image. From the experimental results, suggested technique that gives a higher embe
... Show MoreIn networking communication systems like vehicular ad hoc networks, the high vehicular mobility leads to rapid shifts in vehicle densities, incoherence in inter-vehicle communications, and challenges for routing algorithms. It is necessary that the routing algorithm avoids transmitting the pockets via segments where the network density is low and the scale of network disconnections is high as this could lead to packet loss, interruptions and increased communication overhead in route recovery. Hence, attention needs to be paid to both segment status and traffic. The aim of this paper is to present an intersection-based segment aware algorithm for geographic routing in vehicular ad hoc networks. This algorithm makes available the best route f
... Show MorePhenomena of an abnormal genitalia was among some specimens of Cicindela aulica Dej.
Collected from Iraq. The fore tarsi of male were asymmetrical having its basal three segments
dilated and clothed beneath with fine bristles as in normal male. While those of the right leg
were found simple as in normal females. Dissection of the genialia of these specimens
showed that they were of two types of both male and female structures.
Lasmiditan (LAS) is a recently developed antimigraine drug and was approved in October, 2019 for the treatment of acute migraines; however, it suffers from low oral bioavailability, which is around 40%.
This study aimed to improve the LAS bioavailability via formulation as nanoemulsionbased in situ gel (NEIG) given intranasally and then compare the traditional aqueous-LASsuspension (AQS) with the two successful intranasal prepared formulations (NEIG 2 and NEIG 5) in order to determine its relative bioavailability (F-relative) via using rabbits.
Improving the environment is a mission that should be conducted by three associates; public authorities, environmentalists and the community. The ignorance of environmental education in Iraq has resulted to an almost environmentally illiterate community, demanding well planned programs to raise their environmental; awareness and education. On the other hand, the decision makers should be well informed about the citizens' environmental preferences to be able to set their priorities for the civil services. Merging the Iraqi citizens in listing their environmental priorities is one of many other approaches for "Environment Education" programs. Globally, such methods have proven to be effective and resulted to widespread understandin
... Show MoreThe inhibitive effect of imidazol on the dissolution of Zn in (1M) HCl has been studied. The inhibion effect of imidazol ,protection efficiency and the corrosion rate of Zn in (1M) HCl were investigated at various concentrations (1x 10-3 – 5x10-3) M and tempearture range (285-328) K. The corrosion inhibitive of Zn by imidazol was studied using weight loss measurement and analytical titration of the amounts of dissolved zinc in acidic solution in presence and absent of imidazol. It was observed that imidazol led to protection efficiency reached to (88.93)% when (10)mM imidazol concentration was used. A linear relationship came true between (C/?) and (C); where (?) is the coverage of Zn surface by imidazol which could be obtained from
... Show MoreThe effect of mixed corrosion inhibitors in cooling system was evaluated by using carbon steel specimens and weight loss analysis. The carbon steel specimens immersed in mixture of sodium phosphate (Na2 HPO4) used as corrosion inhibitor and sodium glocunate (C6 H11 NaO7) as a scale dispersant at different concentrations (20,40, 60, 80 ppm) and at different temperature (25,50,75 and 100)ºC for (1-5) days. The corrosion inhibitors efficiency was calculated by using uninhibited and inhibited water to give 98.1%. The result of these investigations indicate that the corrosion rate decreases with the increase the corrosion inhibitors concentration at 80 ppm and at 100ºC for 5 days, (i.e,
... Show MoreThe corrosion of low carbon steel boiler tubes in demi water had been investigated. The purpose of this investigation was to determine the change produced in corrosion behavior of the carbon steel as a result of the specific presence of chloride and copper ions in the water under different temperatures. For low carbon steel experiments, the temperature was taken in three levels (125, 175, and 215°C) under about 27 bar pressure and 1500 rpm in autoclave. Using weight loss technique, the corrosion rate ranges from (85 to 789 gmd) for low carbon steel boiler tubes.