Preferred Language
Articles
/
jbcd-1090
Cone Beam Computed Tomography in an Evaluation and Diagnosis of Anatomical Variations and Pathological Lesions in Maxillary Sinus Prior to Maxillary Sinus Lift Surgery
...Show More Authors

Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner reconstruction window in which the axial, coronal and sagittal plane could be visualized in 0.3 mm interval, 40 were smokers and 20 nonsmokers, both sides were evaluated to assess the presence of septa, maxillary sinus membrane (Schneiderian membrane)thickening, complete opacification and adenoid polyp. Result:The maxillary for nonsmoker patients (20) patients were clean and have no any pathological or anatomical changes, among smoker patients, it was found that 7 (17.5%) of them had a clean maxillary sinus, 25 (62.5%) patient from smokers, the mucosal thickening was clear and measured more than 4 mm, 20 (80%) of them bilateral maxillary sinus were involved and 5 (20%) of them have a unilateral thickening, 6 (15%) of the smoker patient have bilateral involved adenoid with max sinus, and 2(5%) of them have full opacification., no septa was found in this study. Conclusion:Cone Beam Computed Tomography(CBCT)was themost useful technique to diagnose maxillary sinusbefore maxillary sinus augmentation, an evaluation ofCone Beam Computed Tomography(CBCT)scans before implant surgery or sinus augmentation procedures has extreme clinical importance in evaluation of anatomic structures, such as thickening of the Schneiderian membrane and presence of pathological lesion such as adenoid polyp. Key words: Cone beam computed tomography, maxillary sinus, anatomical variations.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
International Journal For Light And Electron Optics
Optical properties of Ag-doped nickel oxide thin films prepared by pulsed-laser deposition technique
...Show More Authors

In this work, pure and Ag-doped nickel oxide (NiO) thin films were deposited on glass substrates with different dopant concentrations (0.1, 0.2, 0.3 and 0.4 wt.%) by pulsed-laser deposition (PLD) technique at room temperature. These films were annealed at temperature of 450 °C. The structural and optical properties of the prepared thin films were studied. It was found that annealing process has lead to increase the transmittance of the deposited films. Also, the transmittance was found to increase with doping concentration of silver in the deposited NiO films. The optical energy gap was decreased from 3.5 to 3.2 eV as the doping concentration was increased to 0.4 %.

View Publication
Scopus (27)
Crossref (24)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Fuzzy Multi-Objective Capacitated Transportation Problem with Mixed Constraints using different forms of membership functions
...Show More Authors

In this research, the problem of multi- objective modal transport was formulated with mixed constraints to find the optimal solution. The foggy approach of the Multi-objective Transfer Model (MOTP) was applied. There are three objectives to reduce costs to the minimum cost of transportation, administrative cost and cost of the goods. The linear membership function, the Exponential membership function, and the Hyperbolic membership function. Where the proposed model was used in the General Company for the manufacture of grain to reduce the cost of transport to the minimum and to find the best plan to transfer the product according to the restrictions imposed on the model.

View Publication Preview PDF
Crossref
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Increase the Intelligibility of Multispectral Image Using Pan-Sharpening Techniques for Many Remotely Sensed Images
...Show More Authors

 Pan sharpening (fusion image) is the procedure of merging suitable information from two or more images into a single image. The image fusion techniques allow the combination of different information sources to improve the quality of image and increase its utility for a particular application. In this research, six pan-sharpening method have been implemented between the panchromatic and multispectral images, these methods include Ehlers, color normalize, Gram-Schmidt, local mean and variance matching, Daubechies of rank two and Symlets of rank four  wavelet transform. Two images captured by two different sensors such as landsat-8 and world view-2 have been adopted to achieve the fusion purpose. Different fidelity metric like MS

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 18 2023
Journal Name
Asia-pacific Journal Of Chemical Engineering
Facile preparation of dual functions zeolite‐carbon composite for zinc ion removal from aqueous solutions
...Show More Authors
Abstract<p>The cost‐effective dual functions zeolite‐carbon composite (DFZCC) was prepared using an eco‐friendly substrate prepared from bio‐waste and an organic adhesive at intermediate conditions. The green synthesis method used in this study ensures that chemically harmless compounds are used to obtain a homogeneous distribution of zeolite over porous carbon. The greenly prepared dual‐function composite was extensively characterized using Fourier transform infrared, X‐ray diffraction, thermogravimetric analysis, N<sub>2</sub> adsorption/desorption isotherms, field emission scanning electron microscope, dispersive analysis by X‐ray, and point of zero charges. DFZCC had a surface area o</p> ... Show More
View Publication
Scopus (16)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2019
Journal Name
International Journal On Interactive Design And Manufacturing (ijidem)
A real-time automated sorting of robotic vision system based on the interactive design approach
...Show More Authors

View Publication
Scopus (32)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Sat Oct 14 2023
Journal Name
Environmental Monitoring And Assessment
The technique of arsenic elimination from contaminated soil with enhanced conditions by electro-kinetic remediation
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Nonlinear Finite Element Analysis of RCMD Beams with Large Circular Opening Strengthened with CFRP Material
...Show More Authors

This paper presents the non-linear finite element method to study the behavior of four reinforced rectangular concrete MD beams with web circular openings tested under two-point load. The numerical finite elements methods have been used in a much more practical way to achieve approximate solutions for more complex problems.  The ABAQUS /CAE is chosen to explore the behavior of MD beams. This paper also studies, the effect of both size and shape of the circular apertures of MD beams. The strengthening technique that used in this paper is externally strengthening using CFRP around the opening in the MD beams. The numerical results were compared to the experimental results in terms of ultimate load failure and displace

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon May 15 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Open Newton Contes Formula for Solving Linear Voltera Integro-Differential Equation of the First Order
...Show More Authors

  In this work, some of numerical methods for solving first order linear Volterra IntegroDifferential Equations are presented.      The numerical solution of these equations is obtained by using Open Newton Cotes formula.      The Open Newton Cotes formula is applied to find the optimum solution for this equation.      The computer program is written in (MATLAB) language (version 6)

View Publication Preview PDF
Publication Date
Wed Nov 30 2022
Journal Name
Desalination And Water Treatment
Removal of amoxicillin from wastewater by adsorption onto activated carbon prepared from sunflower seed hulls
...Show More Authors

In this study, the potential of adsorption of amoxicillin antibiotic (AMOX) from aqueous solutions using prepared activated carbon (AC) was studied. The used AC was prepared from an inexpensive and available precursor (sunflower seed hulls (SSH)) and activated by potassium hydroxide (KOH). The prepared AC was examined for its ability to remove AMOX from aqueous contaminated solutions and characterized with the aid of N2 -adsorption/desorption isotherm Brunauer–Emmett– Teller, scanning electron microscopy, energy-dispersive X-ray spectroscopy and Fourier-transform infrared. Zeta potential of the prepared activated carbon from sunflower seed hulls (SSHAC) were studied in relation to AMOX adsorption. The physical and chemical propert

... Show More
View Publication Preview PDF
Crossref (2)
Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Fast lightweight encryption device based on LFSR technique for increasing the speed of LED performance
...Show More Authors

LED is an ultra-lightweight block cipher that is mainly used in devices with limited resources. Currently, the software and hardware structure of this cipher utilize a complex logic operation to generate a sequence of random numbers called round constant and this causes the algorithm to slow down and record low throughput. To improve the speed and throughput of the original algorithm, the Fast Lightweight Encryption Device (FLED) has been proposed in this paper. The key size of the currently existing LED algorithm is in 64-bit & 128-bit but this article focused mainly on the 64-bit key (block size=64-bit). In the proposed FLED design, complex operations have been replaced by LFSR left feedback technology to make the algorithm perform more e

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref