Abstract: Thorough assessment of the Maxillary,Sinus is very important. Recently 3-dimensional imagewith Cone Beam Computed Tomography (CBCT) is very dependable in Maxillary Sinus diagnosis. The aim of this study is to: shade light on the role of (CBCT) diagnosis of the maxillary sinus anatomical variation and pathological finding among smokers and nonsmokers prior to maxillary sinus lift techniques. Materials and Method: In this study 60 males with age ranged between 20-50 years old, referred for (CBCT) assessment of maxillary sinus in the Specialist Health Center of AL-Sadder city. The scanning were performed using Kodak 9500 (CBCT), the KV was 90, mA10 and scanning time 10 s. Voxel size 0.3mm with( DICOM ) software on a multiplaner reconstruction window in which the axial, coronal and sagittal plane could be visualized in 0.3 mm interval, 40 were smokers and 20 nonsmokers, both sides were evaluated to assess the presence of septa, maxillary sinus membrane (Schneiderian membrane)thickening, complete opacification and adenoid polyp. Result:The maxillary for nonsmoker patients (20) patients were clean and have no any pathological or anatomical changes, among smoker patients, it was found that 7 (17.5%) of them had a clean maxillary sinus, 25 (62.5%) patient from smokers, the mucosal thickening was clear and measured more than 4 mm, 20 (80%) of them bilateral maxillary sinus were involved and 5 (20%) of them have a unilateral thickening, 6 (15%) of the smoker patient have bilateral involved adenoid with max sinus, and 2(5%) of them have full opacification., no septa was found in this study. Conclusion:Cone Beam Computed Tomography(CBCT)was themost useful technique to diagnose maxillary sinusbefore maxillary sinus augmentation, an evaluation ofCone Beam Computed Tomography(CBCT)scans before implant surgery or sinus augmentation procedures has extreme clinical importance in evaluation of anatomic structures, such as thickening of the Schneiderian membrane and presence of pathological lesion such as adenoid polyp. Key words: Cone beam computed tomography, maxillary sinus, anatomical variations.
The cytotoxicity of different concentrations of purified methionine γ- lyase from Pseudomonas putida on cancer cell lines (RD, AMN3 and AMGM) at 96 hr was studied. The bacterial enzyme with concentration 1000µg/ml was revealed highly cytotoxicity against cancer cell lines in comparison with other concentrations whereas slight cytotoxicity was observed on normal cell (REF).
Due to increased consumption of resources, especially energy it was necessary to find alternatives characterized by the same quality as well as being of less expensive, and most important of these alternatives are characterized by waste and the fact that humancannot stop consumption. So we have consideredwaste as an alternative and cheap economic resources and by using environmental index the MIP (input materials per unit ,unit / service) is based on the grounds that the product is not the end of itselfit is a product to meet the need of a product or service, awarded a resource input and output within the five basic elements are the raw materials is ecological, Raw materials ecological, water, air and soil erosion for a
... Show MoreToxic substances have been released into water supplies in recent decades because of fast industrialization and population growth. Fenton electrochemical process has been addressed to treat wastewater which is very popular because of its high efficiency and straightforward design. One of the advanced oxidation processes (AOPs) is electro-Fenton (EF) process, and electrode material significantly affects its performance. Nickel foam was chosen as the source of electro-generated hydrogen peroxide (H2O2) due to its good characteristics. In the present study, the main goals were to explore the effects of operation parameters (FeSO4 concentration, current density, and electrolysis time) on the catalytic performance that was optimized by r
... Show MoreIndium Antimonide (InSb) thin films were grown onto well cleaned glass substrates at substrate temperatures (473 K) by flash evaporation. X-ray diffraction studies confirm the polycrystalline of the films and the films show preferential orientation along the (111) plane .The particle size increases with the increase of annealing time .The transmission spectra of prepared samples were found to be in the range (400-5000 cm-1 ) from FTIR study . This indicates that the crystallinity is improved in the films deposited at higher annealing time.
This study relates to synthesis of bentonite-supported iron/copper nanoparticles through the biosynthesis method using eucalyptus plant leaf extract, which were then named E-Fe/Cu@B-NPs. The synthesised E-Fe/Cu@B-NPs were examined by a set of experiments involving a heterogeneous Fenton-like process that removed direct blue 15 (DB15) dye from wastewater. The resultant E-Fe/Cu@B-NPs were characterised by scanning electron microscopy, Brunauer–Emmet–Teller analysis, zeta potential analysis, Fourier transform infrared spectroscopy and atomic force microscopy. The operating parameters in batch experiments were optimised using Box–Behnken design. These parameters were pH, hydrogen peroxide (H2O2
... Show MoreLet
Clean water supply is one of the major factors contributing significantly to society’s socio-economic transformation by improving living standards, health, and increasing productivity. It is imperative to plan and construct appropriate water supply systems in modern society, which supply various segments of society with safe drinking water according to their requirements to ensure adequate and quality water supply. In the current study, here was an attempt to develop a model for geographic information systems to manage the assets of the water distribution networks in the Karrada region and to evaluate the network geometrically, and from the results of the engineering analysis of the
Objective: To evaluate the functional outcomes after extended curettage and reconstruction using a combination of bone graft and bone cement (sandwich). Methodology: In this prospective case series 16 skeletally mature patients with primary giant cell tumor around the knee were included. Patients with previous surgically treated, malignant transformation, degenerative knee changes and those presenting with pathological fracture were excluded. The tumor was excised with bone graft filling space beneath the articular cartilage and a block of gel foam was placed over the cortical surface of picked bone graft. Remaining cavity was filled with polymethylmethacrylate cement (sandwich) with or without internal fixation. The func tional evaluation
... Show MoreIn this work, porous silicon gas sensor hs been fabricated on n-type crystalline silicon (c-Si) wafers of (100) orientation denoted by n-PS using electrochemical etching (ECE) process at etching time 10 min and etching current density 40 mA/cm2. Deposition of the catalyst (Cu) is done by immersing porous silicon (PS) layer in solution consists of 3ml from (Cu) chloride with 4ml (HF) and 12ml (ethanol) and 1 ml (H2O2). The structural, morphological and gas sensing behavior of porous silicon has been studied. The formation of nanostructured silicon is confirmed by using X-ray diffraction (XRD) measurement as well as it shows the formation of an oxide silicon layer due to chemical reaction. Atomic force microscope for PS illustrates that the p
... Show More