Background: Masseter muscle is one of the most obvious muscles of mastication and considered as one indicator of jaw muscle activity. It has a major influence on the transverse growth of the midface and the vertical growth of the mandible. This study undertaken to determine the role of cephalometric analysis for discrimination between Cl I and Cl III skeletal relationships, determine the role of ultrasonography in determination of masseter muscle thickness, compare masseter muscle thickness between Cl I and Cl III skeletal relationships, and determine the effect of gender on masseter muscle thickness. Material and Method: The sample of the current study consisted of 70 Iraqi subjects 40 males and 30 females with age ranging 18-25 years. They were divided into 2 groups depending on ANB angle: class I skeletal relationship 20 males and 15 females and class III skeletal relationship 20 males and 15 females. The collected sample included patients attended for different diagnostic purposes to the Dental Radiology Department at College of Dentistry/Babylon University, standardized lateral cephalogram was taken to determine facial morphology, six angular and eight linear measurements were assessed. Masseter muscle thickness measured ultrasonography in Al-Hilla General Teaching Hospital/Ultrasonorgaphic Department, in relaxation and contraction conditions for both sides. Results: Various parameters measured for males and females in each class and the comparison shown statistically significant differences between them (P<0.05). No difference in muscle thickness between right and left sides in the same class (P>0.05). Gender variation showed significant difference in masseter muscle thickness during rest and occlusion conditions (P<0.001). Conclusion: Cephalometric analysis served to demonstrate the skeletal morphologies and provide a base for discrimination between class I and class III skeletal relationships. Ultrasonographic scanning is an important imaging procedure. It is reproducible and simple method for accurately measuring masseter muscle thickness. The ultrasonorgaphic study has revealed variations in masseter muscle thickness among individuals with different skeletal morphologies in each gender on one hand and between males and females in each skeletal class on the other hand. Key words: Masseter muscle thickness, skeletal morphology, cephalometric analysis, ultrasonorgaphic scanning.
This research presents an experimental investigation of the rehabilitation efficiency of the damaged hybrid reinforced concrete beams with openings in the shear region. The study investigates the difference in retrofitting ability of hybrid beams compared to traditional beams and the effect of two openings compared with one opening equalized to two holes in the area. Five RC beams classified into two groups, A and B, were primarily tested to full-failure under two-point loads. The first group (A) contained beams with normal weight concrete. The second group (hybrid) included beams with lightweight concrete for web and bottom flange, whereas the top flange was made from normal concrete. Two types of openings were considered in this s
... Show MoreAbstract
Purpose of this study is to investigate the relationship between Advertising Appeals, Attitudes toward Advertising, and Consumer Buying Behavior for Smart Phone The study was carried out on the students of Middle East University (MEU) In Amman- Jordan. A measurement scales with acceptable reliability and validity is developed to capture the dimensions of study variables. Four hypotheses were tested using Statistical package (SPSS-17). A two-step detailed statistical analysis of data was involved. First, descriptive statistics was performed to understand the underlying components of study variables; second, regression analysis and Path analysis using AMOS 7 were performed t
... Show MoreTwo simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A l
... Show MoreA new ligand N-(methylcarbamothioyl) acetamide (AMP) was synthesized by reaction of acetyl chloride with adenine. The ligand was characterized by FT-IR, NMR spectra and the elemental analysis. The transition metal complexes of this ligand where synthesize and characterized by UV-Visible spectra, FT-IR, magnetic suscepility, conductively measurement. The general formula [M(AMP)2Cl2], where M+2 = (Mn, Co, Ni, Cu, Zn, Cd, Hg).
This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation
... Show MoreBackground: Preoperative radiographical assessment of the maxillofacial lesions is of a great importance in guiding the surgeon during surgical procedure in reducing post-operative complications. This study highlighted the application of CBCT scan in the assessment of maxillofacial cystic and cystic like lesions as a part of advanced radiology Materials and methods: A total of 20 patients (15 males and 5 females) participated in this prospective study. CBCT scan (Kodak 9500 CBCT) with (DICOM) software utilized to perform scanning to all patients in order to assess lesion extension, morphological features and it’s relation to the adjacent vital structures. Results: In this study, the total cystic and cystic like lesions involving the
... Show MoreUsing sodium4-((4,5-diphenyl-imidazol-2-yl)diazenyl)-3-hydroxynaphthalene-1-sulfonate (SDPIHN) as a chromogenic reagent in presence of non-ionic surfactant (Triton x-100) to estimate the chromium(III) ion if the wavelength of this reagent 463 nm to form a dark greenish-brown complex in wavelength 586 nm at pH=10,the complex was stable for longer than 24 hours. Beer's low, molar absorptivity 0.244×104L.mol-1.cm-1, and Sandal's sensitivity 0.021 µg/cm2 are all observed in the concentration range 1-11 µg/mL. The limits of detection (LOD) and limit of quantification (LOQ), respectively, were 0.117 µg/mL and 0.385µg/mL. (mole ratio technique, job's method) were employed to
... Show MoreYohimbine is actually confirmed in the United States to be utilized for erectile dysfunction; and recently such drug has become commonly used in body-building communities for its presumed lipolytic and sympathomimetic effects. But ingestion of such drug can bring about epileptic neurotoxic effects.
Many antiepileptic drugs can be utilized to counteract myoclonic seizure; furthermore, diazepam can be used to oppose such type of seizure; in addition, surrogate therapeutic options such as omega 3 may also be utilized.
In this study, twenty-four (24) mice of both sexes weighing 20-25g were randomly-allocated into 4 groups (6 animals each group) as follows: Group I-
... Show More