Background: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals shape was determined using Photoshop CS2 and AutoCAD software. The data were analyzed statistically using ANOVA and LSD test. Results: In terms of centering ratio values, there was no statistically significant difference among the four groups at the coronal portion of the canals, with ProTaper system showing the least centering ability at all levels except at apical foramen. At the apical curvature, the Reciproc and WaveOne groups showed better centering ability than ProTaperNext and the difference was statistically highly significant among them at these points, while at the coronal curvature the ProTaperNext showed better centering ability than Reciproc and WaveOne. Canal transportation was seen in all groups but the ProTaper systems showed more transportation values at almost levels when compared with the other groups with the least values by ProTaperNext at the coronal curvature and the least values by Reciproc and WaveOne at the apical curvature. Conclusions: Under the conditions of this study, ProtaperNext ,WaveOne and Reciproc instruments maintained the original curvature significantly better than ProTaperUniversal at almost levels. ProtaperNext showed a better shaping ability than Reciproc and WaveOne at the coronal curved section while at apical curved section Reciproc and WaveOne showed a better shaping ability than ProtaperNext. Key words: centering ability, canal transportation, ProTaperNext, Reciproc, WaveOne.
A total of 215 sheep and 87 goats were carefully searched for ixodid ticks from January to December 2015 at different regions of the middle and south of Iraq. The detached ticks count 1533 ticks from sheep with intensity of 8.4 and count 332 ticks from goats with intensity of 6.8. Tick species recovered from sheep and their incidence rates were: Rhipicephalus turanicus (39%), Hyalomma anatolicum (28%), R. (Boophilus) annulatus (11%), Hyalomma sp. (9%), H. turanicum (6%), H. excavatum (6%) and R. leporis (1%) while the tick species recovered from goats and their incidence rates were: R. turanicus (64%), H. anatolicum (24%)
... Show Morecharacteristic tissues and cells, exerting their pharmacological aspects and alleviating a lot of diseased processes. Accordingly, this research is about introducing some isatins to be nucleophilically attacked at C3 forming products of azomethine ylide functionality. These iminium compounds were made by allowing certain isatins to be reacted with the secondary amino acid, proline, at acetic acid and methanol medium and then collected after purification to be identified with total Leukocyte count (TLC) and melting point. The structural characterization was performed by fourier-transform infrared spectroscopy (FTIR), proton nuclear magnetic resonance (1H-NMR), and community health nursing (CHN) analysis. The microbiological evaluatio
... Show MoreBiomedical alloy 316L stainless steel enhancing to replace biological tissue or to help stabilize a biological structure, such as bone tissue, enhancing were coated with deposition a thin layer of silver nanoparticles as anti-bacterial materials by using DC- magnetron sputtering device. The morphology surface of The growth nanostructure under the influence of different working pressure were studied by atomic force microscope. The average grain size decrease but roughness of the silver thin layer was increased with‖ ―increasing the working pressure. The thickness of silver thin layer was increased from 107 nm at 0.08 mbar to 126 nm at 1.1 mbar. Antimicrobial activity of silver thin layers at different working pressure were studied. Th
... Show MoreFurosemide drug determination in pharmaceutical and biological urine samples using a novel continuous flow-injection analysis technique that is simple, rapid, sensitive and economical. The complex formed by the reaction of furosemide and O-phenylenediamine with oxidative agent K3[Fe(CN)6] to produce an orange-yellow colored product at 460 nm was the basis for the proposed method. The proposed method’s linearity ranges (3-100) μg.mL-1and (1-50) μg.mL-1 for CFIA/merging zone methods and batch .The detection limit and Limit of quantification values were 2.7502 μg.mL-1 and 9.1697 μg.mL-1 the relative standard deviation was 0.7143 %, and the average recovery is 98.80%
... Show MoreIn research we prepared electrical conductive polymer mixture wich consisted of three polymers [pectin, poly vinyl acetate and poly Aniline] was prepared then doping silver nanoparticles. Meaning it was conducting research on the three stages the first is Preparing triple polymer blend , Preparing silver nanoparticles and Tchoub mix triple Article nanoparticles in different proportions to get (Nanopolymer composites), and Preparing and making chips complexes in (casting method) for the purpose of measuring electrical conductivity her. Also we examined samples spectrum infrared (FT-IR), X-ray diffraction), SEM microscope and atomic force microscopy AFM. Electrical conductivity of the device chips have been measured (LCR) resul
... Show MoreCadmium oxide (CdO) thin films were deposited using the sequencing ion layer adsorption and reaction (SILAR) method. In this study, the effect of the pH value of an aqueous solution of cadmium acetate at a concentration of 0.2 mol of the cadmium oxide film was determined. The solution source for the cadmium oxide film was cadmium ions and an aqueous ammonia solution. The CdO films were deposited on glass substrates at a temperature of 90 ℃. The cadmium oxide film thickness was determined by the weight difference method at pH values (7.2, 8.2). X-ray diffraction (XRD) and scanning electron microscopy (SEM) showed that the size of the crystals increased with the increase in the solution (pH). While the UV-visible spectra of the fil
... Show MoreWe discussed the proper preparation, directing, and implementation of physical education lessons, and clarification of the duties that fall upon the physical education teacher in addition to his physical and skill duties, which is the duty of the physical education lesson. The problem of the research lies in the fact that interactive harmonic exercises are not implemented accurately by physical education teachers because they require great experience, exceptional efforts, and accuracy in performance. The research aims to identify the level of some physical and motor abilities and intelligence among students aged (9-10) years, and to know the effect of some harmonic exercises. Interactivity at the level of some physical and motor abi
... Show MoreTwenty five samples out of sixty wound swabs taken from burn patients were identified as P. aeruginosabacteria by conventional methods. Antibiotics susceptibility tests were performed against thirteen antibiotics. P. aeruginosa samples were treated with 0.5 mg/ml of Safranin O solution then irradiated with 532nm Q-switched Nd:YAG laser at four energy densities (0.324, 0.704, 1.380, and 1.831 J/cm2) for different times of 5, 8 and 11 minutes with 5Hz repetition rate. The viability, susceptibility to antibiotic and production of pyocyanin were determined before and after irradiation. The results showed that the number of CFU/ml of P. aeruginosa decreased with increasing the dose of irradiation. Complete killing of cells was observed at 1.8
... Show More