Preferred Language
Articles
/
jbcd-1080
A Comparison between the Horizontal Condylar and Bennett Angles of Iraqi Full Mouth Rehabilitation Patients by Using Two Different Articulator Systems (An In-Vivo Study)
...Show More Authors

Background: Errors of horizontal condylar inclinations and Bennett angles had largely affected the articulation of teeth and the pathways of cusps. The aim of this study was to estimate and compare between the horizontal condylar (protrusive) angles and Bennett angles of full mouth rehabilitation patients using two different articulator systems. Materials and Methods: Protrusive angles and Bennett angles of 50 adult males and females Iraqi TMD-free full mouth rehabilitation patients were estimated by using two different articulator systems. Arbitrary hinge axis location followed by protrusive angles and Bennett angles, estimation was done by a semiadjustable articulator system. A fully adjustable articulator system was utilized to locate the terminal hinge axis using a kinematic face bow followed by protrusive angles location by the aid of two square shaped transparent hard plastic protractors attached close to the condylar stylus of the articulator followed by Bennett angles calculation according to the Hanau formula. All results were subjected to statistical analyses. Results: The two articulator systems scored protrusive angles for male patients greater than female patients which were non-significant for the fully adjustable articulator but they were significant for the semiadjustable articulator. Non-significance existed between females of the fully adjustable articulator and males of the semiadjustable articulator while high significance was located between males of the fully adjustable articulator and females of the semiadjustable articulator. Concerning Bennett angles, the highest mean value belonged to the male group of the fully adjustable articulator, while the lowest scored by the female group of the semiadjustable articulator. Highly significant differences were located between the Bennett angle mean values of the groups. Conclusion: Using both articulators, the total mean values of the males were greater than the females regarding both horizontal condylar angles and Bennett angles with the total means scored by the fully adjustable articulator being larger than those of the semi-adjustable type. Using both articulators, the males' right and left condyles exhibited greater Bennett angles than their female equivalents. The precision estimation of the horizontal condylar angles and Bennett angles provided by the condylar axis protractors of the fully adjustable articulator render such type of articulators most suitable for treating full mouth rehabilitation cases. Keywords: Horizontal codylar angles, Bennett angles, two articulator systems.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 03 2021
Journal Name
Structural Concrete
Finite element analysis of rectangular RC beams strengthened with FRP laminates under pure torsion
...Show More Authors

Scopus (24)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Thu Jan 03 2019
Journal Name
Journal Of Global Pharma Technology
Antibacterial Activity of New Synthesized Derivatives 3-Substituted Imidazo Benzothiazole from 2- amino- benzothiazole
...Show More Authors

Scopus (4)
Scopus
Publication Date
Wed Dec 29 2021
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Magnetorheological Normally Close Directional Control Valve: Magnetorheological normally close directional control valve
...Show More Authors

This valve is intended for use in valves for steering movement, using the qualities of the Magneto-rheological (MR) fluid to regulate the fluid, direct contact without the utilization of moving parts like a spool, a connection between electric flux, and fluid power was made, The simulation was done to employ the" finite element method of magnetism (FEMM)" to arrive at the best design. This software is used for magnetic resonance valve finite element analysis. The valve's best performance was obtained by using a closed directional control valve in the normal state normally closed (NC) MR valve, with simulation results revealing the optimum magnetic flux density in the absence of a current and the shedding condition, as well as the optimum

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Tue Dec 11 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Burden of Mothers’ Care for Children with Colostomy at Baghdad Medical City Teaching Hospital
...Show More Authors

Objective(s): To assess the burden of mothers` care for child with colostomy and find out relationships between child and mother socio-demographic data with mothers` burden. Methodology: a descriptive study was conducted from 1 August 2013 to 1 September 2014. The sample consisted of 100 children and their mothers at Baghdad Teaching hospital in Baghdad city. A questionnaire was prepared based on the previous literature review, meeting mothers of children with colostomy, and the Zarit Burden Interview scale. Data has collected through the application of questionnaire and interview techniques. Results: T

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 01 2026
Journal Name
Journal Of Nanostructures
Synthesis of New Polymeric Composite Materials Derived from 2,2-(1,6-Dioxohexane-1,6-diyl) Dihydrazinecarbothioamide
...Show More Authors

In this study, a new class of polymeric nanocomposites was synthesized and characterized.  One mole of dimethyl adipate and two moles of thiosemicarbazide in ethanol first reacted to form the compound [C1]. Compound [C1] then reacted with sodium hydroxide to produce compounds [C2]. Hydrazine hydrate reacted with compound [C2] to generate compound [C3]. Compound [C4] was synthesized from compound [C3] and maleic anhydride. A polymer [C5] is formed by the reaction of the compound [C4] with ammonium persulfate as an initiator. This polymer was then combined with nano: ZnNPs, AgNPs, SiNPs, or IONPs using a hotplate stirrer for 3 hours to produce nanocomposites [C6-C9]. FTIR, 1H-NMR, and Field Emission Scanning Electron Microscope (FESEM) were

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Applied Biology & Biotechnology
Field treatment of three wheat varieties with Trichoderma harzianum bioagent to control Anguina tritici
...Show More Authors

View Publication
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Tue Aug 05 2025
Journal Name
Optik
Optimization of plasmonic Al/TiO₂ thin film characteristics via scanning pulsed fiber laser deposition
...Show More Authors

The deposition method of perovskite solar cell layers significantly impacts device functionality and the achievement of industrial goals. Aluminum (Al) nanoparticles with rutile titanium oxide (TiO2) nanoparticle thin films are fabricated on Fluorine Tin Oxide (FTO) glass substrates by nanosecond pulsed fiber laser deposition (PLD) to be used as a plasmonic electron transport layer (ETL) in perovskite solar cell (PSC). The effect of various pulsed fiber laser parameters on the structural, optical, and surface morphology on Al/TiO2 films is extensively examined utilizing a variety of measurement techniques; X-ray diffraction (XRD), Ultraviolet–visible (UV–Vis) spectroscopy, Field emission scanning electron microscopy (FE-SEM) and Atomic

... Show More
Scopus (1)
Scopus
Publication Date
Sat Jan 25 2025
Journal Name
Indonesian Journal Of Chemistry
Synthesis of CuO Nanoparticles from Copper(II) Schiff Base Complex: Evaluation via Thermal Decomposition
...Show More Authors

Copper oxide (CuO) nanoparticles were synthesized through the thermal decomposition of a copper(II) Schiff-base complex. The complex was formed by reacting cupric acetate with a Schiff base in a 2:1 metal-to-ligand ratio. The Schiff base itself was synthesized via the condensation of benzidine and 2-hydroxybenzaldehyde in the presence of glacial acetic acid. This newly synthesized symmetric Schiff base served as the ligand for the Cu(II) metal ion complex. The ligand and its complex were characterized using several spectroscopic methods, including FTIR, UV-vis, 1H-NMR, 13C-NMR, CHNS, and AAS, along with TGA, molar conductivity and magnetic susceptibility measurements. The CuO nanoparticles were produced by thermally decomposing the

... Show More
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Jan 29 2024
Journal Name
Proceedings Of The International Conference On Research Advances In Engineering And Technology - Itechcet 2022
Effect of length to diameter ratio on column bearing capacity stabilized with sodium silicate
...Show More Authors

The numerical analysis was conducted to studying the influence of length to diameter ratio (L/D) on the behavior of the soil treated with sand columns treated with 8% sodium silicate for both floating and end bearing type by using finite element method (Plaxis 3D Foundation ) for isolated foundation of real dimensions. The analysis’s study indicate that in the floating type the best improvement ratio was achieved at (L/D=8) when using columns with a diameter of (0.5, 0.7), but when using columns with a diameter of 0.3 m, it was noticed that the bearing improvement ratio increases with increasing (L/d). While the results of the analysis for end bearing type show that the higher improvement ratio was achieved at (L/D=4) when using columns w

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Mar 18 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of optimal shot peening time on fatigue life for aluminum alloy 6061-T651
...Show More Authors

The compressive residual stresses generated by shot peening, is increased in a direct proportional way with shot peening time (SPT). For each metal, there is an optimum shot peening time (O.S.T) which gives the optimum fatigue life. This paper experimentally studied to optimize shot peening time of aluminium alloy 6061-T651 as well as using of and analysis of variance (ANOVA).

Two types of fatigue test specimens’ configuration were used, one without notch (smooth) and the other with a notch radius (1,25mm), each type was shot peened at different time. The (O.S.T) was experimentally estimated  to be 8 minutes reaching the surface stresses at maximum peak of -184.94 MPa.

A response surface methodology (RSM) is presen

... Show More
View Publication Preview PDF
Crossref (1)
Crossref