Background: Enterococcus faecalis is emerging as an important endodontic pathogen, which can persist in the environment for extended periods after treatment and may cause endodontic failure. It is known to produce biofilms, a community of bacteria enclosed within a protective polymeric matrix. This study aimed to establish whether the biofilm formation by Enterococcus faecalis can be inhibited with steralium, co+steralium, and 5% sodium hypochlorite in the root surface environment. Materials and Methods: Extracted human teeth were biomechanically prepared, vertically sectioned, placed in the tissue culture wells exposing the root canal surface to E. faecalis to form a biofilm. At the end of the 3rd and 6th weeks, all groups were treated for 10 minutes with the previously mentioned tested solutions and control and were analyzed qualitatively and quantitatively. Results: Qualitative assay with 3-weeks biofilm showed a complete inhibition of bacterial growth with co+steralium and NaOCl, except steralium and saline, which showed presence of bacterial growth. In quantitative analysis, steralium and saline- treated tooth samples have 57.74 ± 5.39* CFU/ml., 140.71 ± 8.49 CFU/ml. respectively. Qualitative assay with 6-week biofilm showed growth when treated with steralium and saline treated tooth samples have 346.0 ± 78.88* CFU/ml., 127.18 ± 17.84 CFU/ml. respectively whereas co+steralium and NaOCl has shown complete inhibition. Conclusions: co+steralium and 5% sodium hypochlorite showed maximum antibacterial activity against E. Faecalis biofilm formed on tooth substrate. co+steralium showed statistically significant antibacterial activity. The use of co+steralium as a root canal irrigant might prove to be advantageous considering the several undesirable characteristics of NaOCl. Key words: Biofilm, E. faecalis, steralium, co+steralium, NaOCl, root canal irrigant.
Atenolol was used with ammonium molybdate to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and ammonium molybdate in an aqueous medium to obtain a dark brown precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.1-3.5 mmol/L for cell A and 0.3-3.5 mmol/L for cell B, and LOD 133.1680 ng/100 µL and 532.6720 ng/100 µL for cell A and cell B respectively with correlation coefficient (r) 0.9910 for cell A and 0.9901 for cell B, RSD% was lower than 1%, (n=8) for the determination of ate
... Show MoreThe health care provided by health institutions and all kinds suffers from many problems, and since the health services provided are related to human life, it is necessary to shed light on this activity and identify the causes of these problems. This research aims to Definition of health institutions (hospitals) Performance audit of these institutions according to the latest indicators, which are the standards of health accreditation for hospitals, specifically the basic standards issued by the Health Care Accreditation Council (HCAC) to reach the level of performance and Knowledge of Constraints that lead to in an acceptable manner consistent with the approved standards. In theoretical and practical study, a number of conclusions were r
... Show More